3.5-ton central heat pump · BH714S Series
AC Pro BH714S42P-**A
Below average cooling and heating efficiency for a 3.5-ton central heat pump, but not rated for cold climates.
Ranks #101 of 138 3.5 ton central heat pumps for cooling efficiency, and costs about $1,343 a year to run in a mixed climate like Atlanta.
- SEER2
- 15.5 Cooling efficiency over a seasonBelow average · beats 15%
- HSPF2
- 8.0 Heating efficiency over a seasonBelow average · beats 12%
- EER2
- 13.0 Cooling efficiency on a 95°F dayVery good · beats 89%
- Heat at 5°F
- 20,800 BTU/h51% of its 47°F outputAverage · beats 65%
A good fit if…
- You want a choice of indoor units - 124 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- Cooling cost matters most - its SEER2 is below average for central heat pumps.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- Comfort and noise matter - a single-stage compressor runs only full-on or off.
Details
Specifications
| General | |
|---|---|
| Brand | AC Pro |
| Also sold as | Blueridge, SINCLAIR AIR CONDITIONING |
| Outdoor unit model | BH714S42P-**A |
| Series | BH714S Series |
| Type | Central heat pump |
| Nominal size | 3.5 ton |
| CompressorVariable-speed units run longer at low power | Single stage |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | October 1, 2024 |
| Last certified | October 27, 2025 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 15.5 (range 15.2-15.5) |
| EER2Efficiency at 95°F outdoors | 12.6-13.2 |
| Cooling capacity | 41,000-42,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-8.0 |
| Capacity at 47°F | 39,000-40,000 BTU/h |
| Capacity at 17°F | 24,600-25,400 BTU/h |
| Capacity at 5°F | 19,300-20,800 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.00-2.12 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with BC749[C,U]CT-**+TDR at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 124 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| BC749[C,U]CT-**+TDR | B80UR901E5C | 15.5 | 13.0 | 8.0 | 19,700 | 216371170 |
| BC749[C,U]CT-**+TDR | B80UR1102E5C | 15.5 | 13.2 | 8.0 | 19,400 | 216371167 |
| BC749[C,U]CT-**+TDR | B80UR1102E5C | 15.5 | 13.2 | 8.0 | 19,400 | 216371773 |
| BC749[C,U]CT-**+TDR | B80UR901E5C | 15.5 | 13.0 | 8.0 | 19,700 | 216371776 |
| BC749[C,U]CT-**+TDR | B80UR1102E5C | 15.5 | 13.2 | 8.0 | 19,400 | 216372379 |
| BC749[C,U]CT-**+TDR | B80UR901E5C | 15.5 | 13.0 | 8.0 | 19,700 | 216372382 |
| BC749[C,U]CT-**+TDR | B80UR1101E5C | 15.5 | 13.0 | 7.8 | 19,500 | 216371171 |
| BC749[C,U]CT-**+TDR | B92UR901E3C | 15.5 | 12.8 | 7.8 | 19,400 | 216371172 |
| BC742HBT-**+TDR | B80UR902E4B | 15.5 | 13.0 | 7.8 | 19,500 | 216371196 |
| BC749[C,U]CT-**+TDR | B80UR1002V5CX | 15.5 | 12.8 | 7.8 | 19,600 | 216371179 |
| BC749[C,U]CT-**+TDR | B97UR802V4CX | 15.5 | 12.8 | 7.8 | 19,600 | 216371180 |
| BC748[C,U]CT-**+TDR | B80UR1102E5C | 15.5 | 13.0 | 7.8 | 20,400 | 216371150 |
| BC748[C,U]CT-**+TDR | B80UR901E5C | 15.5 | 13.0 | 7.8 | 20,600 | 216371153 |
| BC742HBT-**+TDR | B80UR901E4B | 15.5 | 13.2 | 7.8 | 19,400 | 216371197 |
| BC749[C,U]CT-**+TDR | B92UR1101E4C | 15.5 | 13.0 | 7.8 | 19,300 | 216371174 |
| BC749[C,U]CT-**+TDR | B92UR1101E5C | 15.5 | 13.0 | 7.8 | 19,600 | 216371175 |
| BC749[C,U]CT-**+TDR | B96UR1101E5C | 15.5 | 12.8 | 7.8 | 19,500 | 216371177 |
| BC749[C,U]CT-**+TDR | B80UR802V4BX | 15.5 | 13.0 | 7.8 | 19,400 | 216371178 |
| BC748[C,U]CT-**+TDR | B92UR1101E4C | 15.5 | 13.0 | 7.8 | 20,200 | 216371157 |
| BC748[C,U]CT-**+TDR | B96UR1101E5C | 15.5 | 12.8 | 7.8 | 20,400 | 216371160 |
| BC748[C,U]CT-**+TDR | B80UR802V4BX | 15.5 | 13.0 | 7.8 | 20,400 | 216371161 |
| BC748[C,U]CT-**+TDR | B92UR1101E4C | 15.5 | 13.0 | 7.8 | 20,200 | 216371763 |
| BC748[C,U]CT-**+TDR | B80UR802V4BX | 15.5 | 13.0 | 7.8 | 20,400 | 216371767 |
| BC748[C,U]CT-**+TDR | B80UR1102E5C | 15.5 | 13.0 | 7.8 | 20,400 | 216371756 |
| BC748[C,U]CT-**+TDR | B80UR901E5C | 15.5 | 13.0 | 7.8 | 20,600 | 216371759 |
| BC748[C,U]CT-**+TDR | B80UR1101E5C | 15.5 | 13.0 | 7.8 | 20,400 | 216371760 |
| BC749[C,U]CT-**+TDR | B97UR1102E5C | 15.5 | 12.8 | 7.8 | 19,900 | 216371775 |
| BC749[C,U]CT-**+TDR | B80UR1101E5C | 15.5 | 13.0 | 7.8 | 19,500 | 216371777 |
| BC749[C,U]CT-**+TDR | B92UR901E3C | 15.5 | 12.8 | 7.8 | 19,400 | 216371778 |
| BC749[C,U]CT-**+TDR | B92UR1101E4C | 15.5 | 13.0 | 7.8 | 19,300 | 216371780 |
| BC749[C,U]CT-**+TDR | B92UR1101E5C | 15.5 | 13.0 | 7.8 | 19,600 | 216371781 |
| BC749[C,U]CT-**+TDR | B96UR1101E5C | 15.5 | 12.8 | 7.8 | 19,500 | 216371783 |
| BC749[C,U]CT-**+TDR | B80UR802V4BX | 15.5 | 13.0 | 7.8 | 19,400 | 216371784 |
| BC749[C,U]CT-**+TDR | B80UR1002V5CX | 15.5 | 12.8 | 7.8 | 19,600 | 216371785 |
| BC749[C,U]CT-**+TDR | B97UR802V4CX | 15.5 | 12.8 | 7.8 | 19,600 | 216371786 |
| BC742HBT-**+TDR | B80UR902E4B | 15.5 | 13.0 | 7.8 | 19,500 | 216371802 |
| BC742HBT-**+TDR | B80UR901E4B | 15.5 | 13.2 | 7.8 | 19,400 | 216371803 |
| BC748[C,U]CT-**+TDR | B96UR1101E5C | 15.5 | 12.8 | 7.8 | 20,400 | 216372372 |
| BC748[C,U]CT-**+TDR | B80UR802V4BX | 15.5 | 13.0 | 7.8 | 20,400 | 216372373 |
| BAH7V42PT- | - | 15.5 | 12.8 | 7.8 | 20,600 | 216372358 |
| BC748[C,U]CT-**+TDR | B80UR1102E5C | 15.5 | 13.0 | 7.8 | 20,400 | 216372362 |
| BC749[C,U]CT-**+TDR | B92UR1101E5C | 15.5 | 13.0 | 7.8 | 19,600 | 216372387 |
| BC749[C,U]CT-**+TDR | B96UR1101E5C | 15.5 | 12.8 | 7.8 | 19,500 | 216372389 |
| BC749[C,U]CT-**+TDR | B80UR802V4BX | 15.5 | 13.0 | 7.8 | 19,400 | 216372390 |
| BC749[C,U]CT-**+TDR | B80UR1002V5CX | 15.5 | 12.8 | 7.8 | 19,600 | 216372391 |
| BC749[C,U]CT-**+TDR | B97UR802V4CX | 15.5 | 12.8 | 7.8 | 19,600 | 216372392 |
| BC742HBT-**+TDR | B80UR902E4B | 15.5 | 13.0 | 7.8 | 19,500 | 216372408 |
| BC742HBT-**+TDR | B80UR901E4B | 15.5 | 13.2 | 7.8 | 19,400 | 216372409 |
| BC748[C,U]CT-**+TDR | B80UR901E5C | 15.5 | 13.0 | 7.8 | 20,600 | 216372365 |
| BC748[C,U]CT-**+TDR | B80UR1101E5C | 15.5 | 13.0 | 7.8 | 20,400 | 216372366 |
| BC748[C,U]CT-**+TDR | B92UR1101E4C | 15.5 | 13.0 | 7.8 | 20,200 | 216372369 |
| BC749[C,U]CT-**+TDR | B97UR1102E5C | 15.5 | 12.8 | 7.8 | 19,900 | 216372381 |
| BC749[C,U]CT-**+TDR | B80UR1101E5C | 15.5 | 13.0 | 7.8 | 19,500 | 216372383 |
| BC749[C,U]CT-**+TDR | B92UR901E3C | 15.5 | 12.8 | 7.8 | 19,400 | 216372384 |
| BC749[C,U]CT-**+TDR | B92UR1101E4C | 15.5 | 13.0 | 7.8 | 19,300 | 216372386 |
| BC748[C,U]CT-**+TDR | B96UR1101E5C | 15.5 | 12.8 | 7.8 | 20,400 | 216371766 |
| BAH7V42PT- | - | 15.5 | 12.8 | 7.8 | 20,600 | 216371752 |
| BC749[C,U]CT-**+TDR | B97UR1102E5C | 15.5 | 12.8 | 7.8 | 19,900 | 216371169 |
| BC748[C,U]CT-**+TDR | B80UR1101E5C | 15.5 | 13.0 | 7.8 | 20,400 | 216371154 |
| BAH7V42PT- | - | 15.5 | 12.8 | 7.8 | 20,600 | 216371146 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,521/yr
- Miami, FL$1,255/yr
- Houston, TX$1,362/yr
- Atlanta, GA$1,343/yr
- Los Angeles, CA$1,299/yr
- New York, NY$3,166/yr
- Chicago, IL$2,562/yr
- Denver, CO$2,123/yr
- Seattle, WA$1,299/yr
- Minneapolis, MN$2,625/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the AC Pro BH714S42P-**A?
- The AC Pro BH714S42P-**A is rated at up to 15.5 SEER2 and 13.0 EER2 for cooling and up to 8.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 124 certified matchups SEER2 ranges from 15.2-15.5.
- Is the AC Pro BH714S42P-**A good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3.5-ton model.
- How much does the AC Pro BH714S42P-**A cost to run per year?
- At its rated efficiency it costs about $1,255-$3,166 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,521 in Phoenix and $2,625 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the AC Pro BH714S42P-**A?
- ENERGY STAR lists 124 certified combinations for this outdoor unit. The highest-rated ones use BC749[C,U]CT-**+TDR, BC742HBT-**+TDR, BC748[C,U]CT-**+TDR.
- What refrigerant does the AC Pro BH714S42P-**A use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 3.5 ton models
- Lennox EL16KP1-042-230A15.5 SEER2 · 8.2 HSPF2
- Century HSA1442S1-**A15.5 SEER2 · 8.0 HSPF2
- GE NS16H42SA5-**A15.5 SEER2 · 8.2 HSPF2
- Bryant 235SAN042**AA15.5 SEER2 · 7.8 HSPF2
- Concord 7HP14F42P-**A15.5 SEER2 · 8.2 HSPF2
- Bryant GH5SAN542**AA15.5 SEER2 · 7.8 HSPF2
- AIREASE A7HP14F42P-**A15.5 SEER2 · 8.2 HSPF2
- Bryant PH5SAN542**AA15.5 SEER2 · 7.8 HSPF2
See all 138 3.5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 27, 2025. How we use the data.