42,000 BTU mini-split heat pump · Ultra heat free match
ACD MUD42KCH23S-O
Below average cooling and heating efficiency for a 42,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #59 of 61 42,000 BTU mini-splits for cooling efficiency, and costs about $1,324 a year to run in a mixed climate like Atlanta.
- SEER2
- 16.0 Cooling efficiency over a seasonBelow average · beats 0%
- HSPF2
- 8.6 Heating efficiency over a seasonBelow average · beats 5%
- EER2
- 9.0 Cooling efficiency on a 95°F dayBelow average · beats 1%
- Heat at 5°F
- 31,200 BTU/h74% of its 47°F outputBelow average · beats 17%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 31,200 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Cooling cost matters most - its SEER2 is below average for mini-splits.
- You mainly need heat - its HSPF2 is below average for mini-splits.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | ACD |
| Outdoor unit model | MUD42KCH23S-O |
| Series | Ultra heat free match |
| Type | Mini-split heat pump |
| Nominal size | 42,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | February 28, 2023 |
| Last certified | June 13, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 16.0 (range 16.0) |
| EER2Efficiency at 95°F outdoors | 9.0 |
| Cooling capacity | 42,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.6 |
| Capacity at 47°F | 42,000 BTU/h |
| Capacity at 17°F | 30,000 BTU/h |
| Capacity at 5°F | 31,200 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.82 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| - · cold climate | 16.0 | 9.0 | 8.6 | 31,200 | 206428587 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,494/yr
- Miami, FL$1,231/yr
- Houston, TX$1,339/yr
- Atlanta, GA$1,324/yr
- Los Angeles, CA$1,281/yr
- New York, NY$3,126/yr
- Chicago, IL$2,531/yr
- Denver, CO$2,098/yr
- Seattle, WA$1,285/yr
- Minneapolis, MN$2,594/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the ACD MUD42KCH23S-O?
- The ACD MUD42KCH23S-O is rated at up to 16.0 SEER2 and 9.0 EER2 for cooling and up to 8.6 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
- Is the ACD MUD42KCH23S-O good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 31,200 BTU/h at 5°F with a COP of 1.82, so it is still 1.8 times as efficient as electric resistance heat at that temperature.
- How much does the ACD MUD42KCH23S-O cost to run per year?
- At its rated efficiency it costs about $1,231-$3,126 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,494 in Phoenix and $2,594 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- What refrigerant does the ACD MUD42KCH23S-O use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 42,000 BTU models
- Trane / Mitsubishi Electric PUZ-HA42NKA1 · cold climate16.3 SEER2 · 9.3 HSPF2
- Trane 4TXM2336A15NU · cold climate16.0 SEER2 · 8.6 HSPF2
- Mitsubishi Electric PUZ-HA42NKA2 · cold climate16.3 SEER2 · 9.3 HSPF2
- Mitsubishi Electric PUZ-HA42NKA · cold climate15.4 SEER2 · 8.9 HSPF2
- TOSOT TGWHD-42ND · cold climate17.0 SEER2 · 8.5 HSPF2
- GE Appliances ASH4248UCDD · cold climate18.0 SEER2 · 8.8 HSPF2
- LG KUSUB421A · cold climate18.5 SEER2 · 9.5 HSPF2
- Fujitsu AOUH42KUAS1 · cold climate19.0 SEER2 · 10.4 HSPF2
See all 61 42,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 13, 2026. How we use the data.