HVAC Rated

12,000 BTU mini-split heat pump · ACIQ Series

ACIQ ACIQ-12ZS-HP115C

Average cooling and heating efficiency for a 12,000 BTU mini-split heat pump, but not rated for cold climates.

Ranks #225 of 394 12,000 BTU mini-splits for cooling efficiency, and costs about $293 a year to run in a mixed climate like Atlanta.

SEER2
23.2 Cooling efficiency over a season
Average · beats 67%
HSPF2
10.4 Heating efficiency over a season
Average · beats 57%
EER2
12.5 Cooling efficiency on a 95°F day
Average · beats 44%
Heat at 5°F
7,300 BTU/h61% of its 47°F output
Very good · beats 78%

A good fit if…

  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.

Calculate my running cost

Details

Specifications12,000 BTU, R-454B
General
BrandACIQ
Also sold as1HVAC
Outdoor unit modelACIQ-12ZS-HP115C
SeriesACIQ Series
TypeMini-split heat pump
Nominal size12,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceFebruary 10, 2025
Last certifiedJune 1, 2026
Cooling
SEER2Seasonal efficiency, higher is better23.2 (range 23.2)
EER2Efficiency at 95°F outdoors12.5
Cooling capacity12,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better10.4
Capacity at 47°F12,000 BTU/h
Capacity at 17°F10,000 BTU/h
Capacity at 5°F7,300 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.20
ENERGY STAR cold climateNo
Heating output as it gets colder61% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with ACIQ-12WS-HP115C at the standard test temperatures, in BTU/h:

Certified matchups3 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
ACIQ-12WS-HP115C23.212.510.47,300216980866
ACIQ-12WS-HP115C 1HVAC23.212.510.47,300216980880
ACIQ-12W-BL-115-MD23.212.510.47,300218457915
Yearly running cost in 10 large cities$244-$714

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the ACIQ ACIQ-12ZS-HP115C?
The ACIQ ACIQ-12ZS-HP115C is rated at up to 23.2 SEER2 and 12.5 EER2 for cooling and up to 10.4 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
Is the ACIQ ACIQ-12ZS-HP115C good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 12,000 BTU model.
How much does the ACIQ ACIQ-12ZS-HP115C cost to run per year?
At its rated efficiency it costs about $244-$714 a year in electricity in large U.S. cities, depending on climate and local rates - for example $309 in Phoenix and $603 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the ACIQ ACIQ-12ZS-HP115C?
ENERGY STAR lists 3 certified combinations for this outdoor unit. The highest-rated ones use ACIQ-12WS-HP115C, 1HVAC ACIQ-12WS-HP115C, ACIQ-12W-BL-115-MD.
What refrigerant does the ACIQ ACIQ-12ZS-HP115C use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $311/yrYou save $307/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump ACIQ ACIQ-12ZS-HP115C
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$311
Current system, per year
$619
You save per year
$307
Payback
14.6 years
Net after 10 years
-$1,425

Cooling $182Heating $129Electricity used: 1,946 kWhSaved vs. a minimum-efficiency heat pump: $163

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 12,000 BTU models

See all 394 12,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 1, 2026. How we use the data.