48,000 BTU mini-split heat pump · ACIQ
ACIQ ACIQ-48ZPL-HP230B
Below average cooling efficiency and very good heating efficiency for a 48,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #136 of 146 48,000 BTU mini-splits for cooling efficiency, and costs about $1,271 a year to run in a mixed climate like Atlanta.
- SEER2
- 17.0 Cooling efficiency over a seasonBelow average · beats 2%
- HSPF2
- 12.0 Heating efficiency over a seasonVery good · beats 89%
- EER2
- 14.0 Cooling efficiency on a 95°F dayVery good · beats 82%
- Heat at 5°F
- 50,000 BTU/h96% of its 47°F outputAverage · beats 59%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 50,000 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 89% of mini-splits.
- You want steady temperatures and quiet running - the compressor varies its speed.
- You want a choice of indoor units - 15 certified pairings.
Think twice if…
- Cooling cost matters most - its SEER2 is below average for mini-splits.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | ACIQ |
| Also sold as | DIYCOOL, 1HVAC, PolarWave, STEALTH |
| Outdoor unit model | ACIQ-48ZPL-HP230B |
| Series | ACIQ |
| Type | Mini-split heat pump |
| Nominal size | 48,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | October 1, 2022 |
| Last certified | May 28, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 17.0 (range 16.8-17.0) |
| EER2Efficiency at 95°F outdoors | 8.2-14.0 |
| Cooling capacity | 48,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.8-12.0 |
| Capacity at 47°F | 51,000-53,000 BTU/h |
| Capacity at 17°F | 35,000-50,000 BTU/h |
| Capacity at 5°F | 48,000-50,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.80-2.02 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with ACIQ-48CD-HH-MB at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| ACIQ-48CD-HH-MB 1HVAC | 17.0 | 14.0 | 12.0 | 50,000 | 210857302 |
| ACIQ-48CD-HH-MB STEALTH | 17.0 | 14.0 | 12.0 | 50,000 | 212316192 |
| ACIQ-48CD-HH-MB DIYCOOL | 17.0 | 14.0 | 12.0 | 50,000 | 210857342 |
| ACIQ-48CD-HH-MB | 17.0 | 14.0 | 12.0 | 50,000 | 210857322 |
| ACIQ-48CD-HH-MB PolarWave | 17.0 | 14.0 | 12.0 | 50,000 | 212316106 |
| ACIQ-48FM-HH-MB · cold climate | 17.0 | 8.2 | 9.8 | 49,000 | 210857325 |
| ACIQ-48FM-HH-MB DIYCOOL · cold climate | 17.0 | 8.2 | 9.8 | 49,000 | 210857345 |
| ACIQ-48FM-HH-MB 1HVAC · cold climate | 17.0 | 8.2 | 9.8 | 49,000 | 210857305 |
| ACIQ-48FM-HH-MB PolarWave · cold climate | 17.0 | 8.2 | 9.8 | 49,000 | 212316109 |
| ACIQ-48FM-HH-MB STEALTH · cold climate | 17.0 | 8.2 | 9.8 | 49,000 | 212316195 |
| ACIQ-48CC-HH-MB DIYCOOL · cold climate | 16.8 | 8.3 | 10.7 | 48,000 | 210857340 |
| ACIQ-48CC-HH-MB · cold climate | 16.8 | 8.3 | 10.7 | 48,000 | 210857320 |
| ACIQ-48CC-HH-MB 1HVAC · cold climate | 16.8 | 8.3 | 10.7 | 48,000 | 210857300 |
| ACIQ-48CC-HH-MB PolarWave · cold climate | 16.8 | 8.3 | 10.7 | 48,000 | 212316104 |
| ACIQ-48CC-HH-MB STEALTH · cold climate | 16.8 | 8.3 | 10.7 | 48,000 | 212316190 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,536/yr
- Miami, FL$1,317/yr
- Houston, TX$1,374/yr
- Atlanta, GA$1,271/yr
- Los Angeles, CA$1,211/yr
- New York, NY$2,893/yr
- Chicago, IL$2,320/yr
- Denver, CO$1,906/yr
- Seattle, WA$1,154/yr
- Minneapolis, MN$2,350/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the ACIQ ACIQ-48ZPL-HP230B?
- The ACIQ ACIQ-48ZPL-HP230B is rated at up to 17.0 SEER2 and 14.0 EER2 for cooling and up to 12.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 15 certified matchups SEER2 ranges from 16.8-17.0.
- Is the ACIQ ACIQ-48ZPL-HP230B good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 50,000 BTU/h at 5°F with a COP of 2.02, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
- How much does the ACIQ ACIQ-48ZPL-HP230B cost to run per year?
- At its rated efficiency it costs about $1,154-$2,893 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,536 in Phoenix and $2,350 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the ACIQ ACIQ-48ZPL-HP230B?
- ENERGY STAR lists 15 certified combinations for this outdoor unit. The highest-rated ones use 1HVAC ACIQ-48CD-HH-MB, STEALTH ACIQ-48CD-HH-MB, DIYCOOL ACIQ-48CD-HH-MB.
- What refrigerant does the ACIQ ACIQ-48ZPL-HP230B use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 48,000 BTU models
- Mitsubishi Electric RUZ-AK48NLHZ · cold climate17.1 SEER2 · 8.9 HSPF2
- Lennox MLB048S4S-1P · cold climate17.0 SEER2 · 12.0 HSPF2
- Star Air Kontrol SAK-48-DT2/220V · cold climate17.1 SEER2 · 9.8 HSPF2
- Lennox MLB048S4S-2P · cold climate17.0 SEER2 · 12.0 HSPF2
- GE Appliances 1G4248ED2BE · cold climate18.0 SEER2 · 10.0 HSPF2
- MDV MOE30U-48HFN1-M-[X](GA) · cold climate17.0 SEER2 · 12.0 HSPF2
- Sea Breeze CSZ60H525ZMO · cold climate18.0 SEER2 · 10.7 HSPF2
- MDV MOE30U-48HFN1-M-[X](GA)-L · cold climate17.0 SEER2 · 12.0 HSPF2
See all 146 48,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 28, 2026. How we use the data.