1.5-ton central heat pump · Bronze 15
American Standard N5HP5018A1
Below average cooling and heating efficiency for a 1.5-ton central heat pump, but not rated for cold climates.
Ranks #157 of 170 1.5 ton central heat pumps for cooling efficiency, and costs about $591 a year to run in a mixed climate like Atlanta.
- SEER2
- 15.2 Cooling efficiency over a seasonBelow average · beats 6%
- HSPF2
- 8.0 Heating efficiency over a seasonBelow average · beats 12%
- EER2
- 12.0 Cooling efficiency on a 95°F dayAverage · beats 64%
- Heat at 5°F
- 8,900 BTU/h53% of its 47°F outputAverage · beats 64%
A good fit if…
- You want a certified 1.5-ton central heat pump at a typical efficiency level.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- Cooling cost matters most - its SEER2 is below average for central heat pumps.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- Comfort and noise matter - a single-stage compressor runs only full-on or off.
Details
Specifications
| General | |
|---|---|
| Brand | American Standard |
| Also sold as | Trane |
| Outdoor unit model | N5HP5018A1 |
| Series | Bronze 15 |
| Type | Central heat pump |
| Nominal size | 1.5 ton |
| CompressorVariable-speed units run longer at low power | Single stage |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | May 26, 2026 |
| Last certified | June 29, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 15.2 (range 15.2) |
| EER2Efficiency at 95°F outdoors | 12.0 |
| Cooling capacity | 18,300-18,500 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.0 |
| Capacity at 47°F | 16,800-17,000 BTU/h |
| Capacity at 17°F | 11,500-11,600 BTU/h |
| Capacity at 5°F | 8,900 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.09-2.11 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 5TXCB006AS3+TSTAT at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| 5TXCB006AS3+TSTAT | A952V060BD3SB | 15.2 | 12.0 | 8.0 | 8,900 | 218470660 |
| 5TXCB006AS3+TSTAT | A952V040BD3SB | 15.2 | 12.0 | 8.0 | 8,900 | 218470659 |
| 5PX*B006AS3+TSTAT | A952V040BD3SB | 15.2 | 12.0 | 8.0 | 8,900 | 218470650 |
| 5PX*B006AS3+TSTAT | A952V060BD3SB | 15.2 | 12.0 | 8.0 | 8,900 | 218470649 |
| 5TXCB006AS3+TSTAT | A952V060BD3SB | 15.2 | 12.0 | 8.0 | 8,900 | 218469958 |
| 5TXCB006AS3+TSTAT | A952V040BD3SB | 15.2 | 12.0 | 8.0 | 8,900 | 218469957 |
| 5PX*B006AS3+TSTAT | A952V040BD3SB | 15.2 | 12.0 | 8.0 | 8,900 | 218469947 |
| 5PX*B006AS3+TSTAT | A952V060BD3SB | 15.2 | 12.0 | 8.0 | 8,900 | 218469946 |
Yearly running cost in 10 large cities
- Phoenix, AZ$682/yr
- Miami, FL$570/yr
- Houston, TX$611/yr
- Atlanta, GA$591/yr
- Los Angeles, CA$569/yr
- New York, NY$1,378/yr
- Chicago, IL$1,112/yr
- Denver, CO$920/yr
- Seattle, WA$561/yr
- Minneapolis, MN$1,136/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the American Standard N5HP5018A1?
- The American Standard N5HP5018A1 is rated at up to 15.2 SEER2 and 12.0 EER2 for cooling and up to 8.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
- Is the American Standard N5HP5018A1 good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 1.5-ton model.
- How much does the American Standard N5HP5018A1 cost to run per year?
- At its rated efficiency it costs about $561-$1,378 a year in electricity in large U.S. cities, depending on climate and local rates - for example $682 in Phoenix and $1,136 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the American Standard N5HP5018A1?
- ENERGY STAR lists 8 certified combinations for this outdoor unit. The highest-rated ones use 5TXCB006AS3+TSTAT, 5PX*B006AS3+TSTAT.
- What refrigerant does the American Standard N5HP5018A1 use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 1.5 ton models
- Thermal Zone TZP15AZ18AJ2N · cold climate15.2 SEER2 · 8.1 HSPF2
- GE NS17H18SA4-15.2 SEER2 · 8.0 HSPF2
- RunTru A5HP5018A115.2 SEER2 · 8.1 HSPF2
- AC Pro SPHP-M-1018BB15.2 SEER2 · 7.8 HSPF2
- Rheem WP15AY18AJ2N · cold climate15.2 SEER2 · 8.1 HSPF2
- Airquest N4H5S18*K*AAA15.2 SEER2 · 7.8 HSPF2
- Mainline MPP15AZ18AJ2N · cold climate15.2 SEER2 · 8.1 HSPF2
- Arcoaire R4H5S18*K*AAA15.2 SEER2 · 7.8 HSPF2
See all 170 1.5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 29, 2026. How we use the data.