HVAC Rated

9,000 BTU mini-split heat pump · DLC-series

Arcoaire DLCSRBH09AAK

Excellent cooling and heating efficiency for a 9,000 BTU mini-split heat pump, and certified for cold climates.

Ranks #37 of 395 9,000 BTU mini-splits for cooling efficiency, and costs about $208 a year to run in a mixed climate like Atlanta.

SEER2
28.1 Cooling efficiency over a season
Excellent · beats 97%
HSPF2
12.4 Heating efficiency over a season
Excellent · beats 93%
EER2
16.2 Cooling efficiency on a 95°F day
Excellent · beats 97%
Heat at 5°F
11,000 BTU/h88% of its 47°F output
Average · beats 48%

A good fit if…

  • You want low cooling bills - its SEER2 beats 97% of mini-splits.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 11,000 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 93% of mini-splits.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications9,000 BTU, R-410A
General
BrandArcoaire
Also sold asComfortmaker, Airquest, Smart Comfort, Heil, Day & Night, Tempstar, Midea, Keeprite, Kenmore, LPS Legacy, Viessmann, Carrier, Bryant
Outdoor unit modelDLCSRBH09AAK
SeriesDLC-series
TypeMini-split heat pump
Nominal size9,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceJanuary 1, 2018
Last certifiedJune 23, 2026
Cooling
SEER2Seasonal efficiency, higher is better28.1 (range 20.2-28.1)
EER2Efficiency at 95°F outdoors13.0-16.2
Cooling capacity9,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better10.0-12.4
Capacity at 47°F9,800-12,000 BTU/h
Capacity at 17°F8,600-10,100 BTU/h
Capacity at 5°F10,000-11,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.80-2.00
ENERGY STAR cold climateYes
Heating output as it gets colder88% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with DLFSHCH09XAK at the standard test temperatures, in BTU/h:

Certified matchups99 indoor units

The same outdoor unit scores differently with each indoor unit. The 60 highest-rated of 99 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
DLFSHCH09XAK COMFORTMAKER · cold climate28.116.211.510,600208447625
DLFSHCH09XAK ARCOAIRE · cold climate28.116.211.510,600208447617
DLFSHCH09XAK AIRQUEST · cold climate28.116.211.510,600208447689
DLFSHCH09XAK SMART COMFORT · cold climate28.116.211.510,600208447681
DLFSHCH09XAK TEMPSTAR · cold climate28.116.211.510,600208447673
DLFSHCH09XAK MIDEA · cold climate28.116.211.510,600208447665
DLFSHCH09XAK KENMORE · cold climate28.116.211.510,600208447657
DLFSHCH09XAK KEEPRITE · cold climate28.116.211.510,600208447649
DLFSHCH09XAK HEIL · cold climate28.116.211.510,600208447641
DLFSHCH09XAK DAY & NIGHT · cold climate28.116.211.510,600208447633
DLFSHCH09XAK LPS Legacy · cold climate28.116.211.510,600211756602
DLFSHCH09XAK Viessmann · cold climate28.116.211.510,600215569842
DHMAHBQ09XA3 ARCOAIRE · cold climate28.116.211.510,600216091461
DHMAHBQ09XA3 COMFORTMAKER · cold climate28.116.211.510,600216091463
DHMAHBQ09XA3 DAY & NIGHT · cold climate28.116.211.510,600216091464
DHMAHBQ09XA3 HEIL · cold climate28.116.211.510,600216091466
DHMAHBQ09XA3 KEEPRITE · cold climate28.116.211.510,600216091468
DHMAHBQ09XA3 MIDEA · cold climate28.116.211.510,600216091471
DHMAHBQ09XA3 TEMPSTAR · cold climate28.116.211.510,600216091473
DHMAHBQ09XA3 SMART COMFORT · cold climate28.116.211.510,600216091474
DHMAHBQ09XA3 AIRQUEST · cold climate28.116.211.510,600216091475
DHMAHBQ09XA3 CARRIER · cold climate28.116.211.510,600216091579
DHMAHBQ09XA3 BRYANT · cold climate28.116.211.510,600216091580
DLFSHCH09XAK SMART COMFORT · cold climate28.116.211.510,600208447681
DLFSHBH09XAK HEIL · cold climate26.415.811.611,000206361884
DLFSHBH09XAK DAY & NIGHT · cold climate26.415.811.611,000206361879
DLFSHBH09XAK COMFORTMAKER · cold climate26.415.811.611,000206361874
DLFSHBH09XAK COMFORTMAKER · cold climate26.415.811.611,000206361874
DLFSHBH09XAK ARCOAIRE · cold climate26.415.811.611,000206361869
DLFSHBH09XAK AIRQUEST · cold climate26.415.811.611,000206361914
DLFSHBH09XAK SMART COMFORT · cold climate26.415.811.611,000206361909
DLFSHBH09XAK TEMPSTAR · cold climate26.415.811.611,000206361904
DLFSHBH09XAK MIDEA · cold climate26.415.811.611,000206361899
DLFSHBH09XAK KENMORE · cold climate26.415.811.611,000206361894
DLFSHBH09XAK KEEPRITE · cold climate26.415.811.611,000206361889
DLFSHBH09XAK LPS Legacy · cold climate26.415.811.611,000211756563
DLFSHBH09XAK Viessmann · cold climate26.415.811.611,000215569797
DLFSHBH09XAK ARCOAIRE · cold climate26.415.811.611,000206361869
DLFCCAH09XAK ARCOAIRE · cold climate24.013.012.410,500209270247
DLFSOAH09XAK AIRQUEST · cold climate24.013.012.410,500210857461
DLFSOAH09XAK SMART COMFORT · cold climate24.013.012.410,500210857457
DLFSOAH09XAK TEMPSTAR · cold climate24.013.012.410,500210857453
DLFSOAH09XAK MIDEA · cold climate24.013.012.410,500210857449
DLFSOAH09XAK KENMORE · cold climate24.013.012.410,500210857445
DLFSOAH09XAK KEEPRITE · cold climate24.013.012.410,500210857441
DLFSOAH09XAK HEIL · cold climate24.013.012.410,500210857437
DLFSOAH09XAK DAY & NIGHT · cold climate24.013.012.410,500210857433
DLFSOAH09XAK COMFORTMAKER · cold climate24.013.012.410,500210857429
DLFSOAH09XAK ARCOAIRE · cold climate24.013.012.410,500210857425
DLFCCAH09XAK AIRQUEST · cold climate24.013.012.410,500209270283
DLFCCAH09XAK SMART COMFORT · cold climate24.013.012.410,500209270279
DLFCCAH09XAK TEMPSTAR · cold climate24.013.012.410,500209270275
DLFCCAH09XAK MIDEA · cold climate24.013.012.410,500209270271
DLFCCAH09XAK KENMORE · cold climate24.013.012.410,500209270267
DLFCCAH09XAK KEEPRITE · cold climate24.013.012.410,500209270263
DLFCCAH09XAK HEIL · cold climate24.013.012.410,500209270259
DLFCCAH09XAK DAY & NIGHT · cold climate24.013.012.410,500209270255
DLFCCAH09XAK COMFORTMAKER · cold climate24.013.012.410,500209270251
DLFCCAH09XAK LPS Legacy · cold climate24.013.012.410,500211756596
DLFSOAH09XAK LPS Legacy · cold climate24.013.012.410,500211756592
Yearly running cost in 10 large cities$152-$526

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Arcoaire DLCSRBH09AAK?
The Arcoaire DLCSRBH09AAK is rated at up to 28.1 SEER2 and 16.2 EER2 for cooling and up to 12.4 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 99 certified matchups SEER2 ranges from 20.2-28.1.
Is the Arcoaire DLCSRBH09AAK good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 11,000 BTU/h at 5°F with a COP of 2.00, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the Arcoaire DLCSRBH09AAK cost to run per year?
At its rated efficiency it costs about $152-$526 a year in electricity in large U.S. cities, depending on climate and local rates - for example $204 in Phoenix and $452 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Arcoaire DLCSRBH09AAK?
ENERGY STAR lists 99 certified combinations for this outdoor unit. The highest-rated ones use COMFORTMAKER DLFSHCH09XAK, ARCOAIRE DLFSHCH09XAK, AIRQUEST DLFSHCH09XAK.
What refrigerant does the Arcoaire DLCSRBH09AAK use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $211/yrYou save $284/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Arcoaire DLCSRBH09AAK
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$211
Current system, per year
$495
You save per year
$284
Payback
12.3 years
Net after 10 years
-$660

Cooling $113Heating $98Electricity used: 1,320 kWhSaved vs. a minimum-efficiency heat pump: $173

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 9,000 BTU models

See all 395 9,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 23, 2026. How we use the data.