24,000 BTU mini-split heat pump · 4DH SERIES
Armstrong Air 4DHP2S24M-1P
Very good cooling efficiency and average heating efficiency for a 24,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #37 of 430 24,000 BTU mini-splits for cooling efficiency, and costs about $596 a year to run in a mixed climate like Atlanta.
- SEER2
- 24.6 Cooling efficiency over a seasonVery good · beats 80%
- HSPF2
- 10.0 Heating efficiency over a seasonAverage · beats 43%
- EER2
- 13.4 Cooling efficiency on a 95°F dayVery good · beats 72%
- Heat at 5°F
- 18,500 BTU/h74% of its 47°F outputBelow average · beats 27%
A good fit if…
- You want low cooling bills - its SEER2 beats 80% of mini-splits.
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 18,500 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
- You want a choice of indoor units - 19 certified pairings.
Think twice if…
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | Armstrong Air |
| Also sold as | Concord, ALLIED, Ducane, AIREASE |
| Outdoor unit model | 4DHP2S24M-1P |
| Series | 4DH SERIES |
| Type | Mini-split heat pump |
| Nominal size | 24,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | January 1, 2022 |
| Last certified | June 29, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 24.6 (range 21.3-24.6) |
| EER2Efficiency at 95°F outdoors | 12.5-13.4 |
| Cooling capacity | 24,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.7-10.0 |
| Capacity at 47°F | 24,000-25,000 BTU/h |
| Capacity at 17°F | 20,400-21,600 BTU/h |
| Capacity at 5°F | 18,000-18,500 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.90 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| - DUCANE · cold climate | 24.6 | 13.4 | 10.0 | 18,500 | 208106845 |
| - · cold climate | 24.6 | 13.4 | 10.0 | 18,500 | 208106815 |
| - Allied · cold climate | 24.6 | 13.4 | 10.0 | 18,500 | 208106785 |
| - CONCORD · cold climate | 24.6 | 13.4 | 10.0 | 18,500 | 208106830 |
| - · cold climate | 24.6 | 13.4 | 10.0 | 18,500 | 208106815 |
| - AirEase · cold climate | 24.6 | 13.4 | 10.0 | 18,500 | 208106800 |
| - CONCORD · cold climate | 23.0 | 13.0 | 9.9 | 18,200 | 208106832 |
| - Allied · cold climate | 23.0 | 13.0 | 9.9 | 18,200 | 208106787 |
| - · cold climate | 23.0 | 13.0 | 9.9 | 18,200 | 208106817 |
| - DUCANE · cold climate | 23.0 | 13.0 | 9.9 | 18,200 | 208106847 |
| - AirEase · cold climate | 23.0 | 13.0 | 9.9 | 18,200 | 208106802 |
| - DUCANE · cold climate | 21.3 | 12.5 | 9.7 | 18,000 | 208106846 |
| - CONCORD · cold climate | 21.3 | 12.5 | 9.7 | 18,000 | 208106831 |
| - AirEase · cold climate | 21.3 | 12.5 | 9.7 | 18,000 | 208106801 |
| - CONCORD · cold climate | 21.3 | 12.5 | 9.7 | 18,000 | 208106831 |
| - · cold climate | 21.3 | 12.5 | 9.7 | 18,000 | 208106816 |
| - Allied · cold climate | 21.3 | 12.5 | 9.7 | 18,000 | 208106786 |
| - Allied · cold climate | 21.3 | 12.5 | 9.7 | 18,000 | 208106786 |
| - · cold climate | 21.3 | 12.5 | 9.7 | 18,000 | 208106816 |
Yearly running cost in 10 large cities
- Phoenix, AZ$604/yr
- Miami, FL$462/yr
- Houston, TX$543/yr
- Atlanta, GA$596/yr
- Los Angeles, CA$590/yr
- New York, NY$1,481/yr
- Chicago, IL$1,213/yr
- Denver, CO$1,018/yr
- Seattle, WA$632/yr
- Minneapolis, MN$1,263/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Armstrong Air 4DHP2S24M-1P?
- The Armstrong Air 4DHP2S24M-1P is rated at up to 24.6 SEER2 and 13.4 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 19 certified matchups SEER2 ranges from 21.3-24.6.
- Is the Armstrong Air 4DHP2S24M-1P good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 18,500 BTU/h at 5°F with a COP of 1.90, so it is still 1.9 times as efficient as electric resistance heat at that temperature.
- How much does the Armstrong Air 4DHP2S24M-1P cost to run per year?
- At its rated efficiency it costs about $462-$1,481 a year in electricity in large U.S. cities, depending on climate and local rates - for example $604 in Phoenix and $1,263 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- What refrigerant does the Armstrong Air 4DHP2S24M-1P use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 24,000 BTU models
- Mitsubishi Electric PUZ-A24NHA824.7 SEER2 · 9.3 HSPF2
- Lennox MPC024S4M-1P · cold climate24.6 SEER2 · 10.0 HSPF2
- Mitsubishi Electric PUZ-A24NHA724.7 SEER2 · 9.3 HSPF2
- MDV M3OJ-24HFN1-M · cold climate24.6 SEER2 · 10.0 HSPF2
- Midea MO4EX-H27B-2B · cold climate25.0 SEER2 · 9.5 HSPF2
- Midea 38MGHBQ24CA3 · cold climate24.6 SEER2 · 10.0 HSPF2
- Midea 37MGRAQ24DA3 · cold climate25.0 SEER2 · 9.5 HSPF2
- Midea MMCMHAQ24CA3 · cold climate24.6 SEER2 · 10.0 HSPF2
See all 430 24,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 29, 2026. How we use the data.