18,000 BTU mini-split heat pump · A-Series
AUX AM2-H18/2DR3A
Average cooling and heating efficiency for a 18,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #217 of 465 18,000 BTU mini-splits for cooling efficiency, and costs about $456 a year to run in a mixed climate like Atlanta.
- SEER2
- 22.0 Cooling efficiency over a seasonAverage · beats 48%
- HSPF2
- 10.0 Heating efficiency over a seasonAverage · beats 43%
- EER2
- 12.3 Cooling efficiency on a 95°F dayBelow average · beats 35%
- Heat at 5°F
- 14,500 BTU/h81% of its 47°F outputAverage · beats 48%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 14,500 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | AUX |
| Also sold as | DELLA, COSTWAY, Premium Levella, HAVELLS |
| Outdoor unit model | AM2-H18/2DR3A |
| Series | A-Series |
| Type | Mini-split heat pump |
| Nominal size | 18,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-32 |
| Connected (smart) capable | No |
| On the market since | May 30, 2024 |
| Last certified | June 25, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 22.0 (range 22.0) |
| EER2Efficiency at 95°F outdoors | 12.3 |
| Cooling capacity | 17,700 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 10.0 |
| Capacity at 47°F | 18,000 BTU/h |
| Capacity at 17°F | 14,700 BTU/h |
| Capacity at 5°F | 14,500 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.00 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| - · cold climate | 22.0 | 12.3 | 10.0 | 14,500 | 214097935 |
Same unit, other model numbers
These model numbers have exactly the same certified ratings and matchups as the AUX AM2-H18/2DR3A: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.
- DELLA 048-MS-18K-MODU
- COSTWAY FP10839US-WH
- Premium Levella PIAWMZ1882280AB
- HAVELLS GSSHAX7641
Yearly running cost in 10 large cities
- Phoenix, AZ$482/yr
- Miami, FL$380/yr
- Houston, TX$432/yr
- Atlanta, GA$456/yr
- Los Angeles, CA$448/yr
- New York, NY$1,113/yr
- Chicago, IL$908/yr
- Denver, CO$758/yr
- Seattle, WA$469/yr
- Minneapolis, MN$940/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the AUX AM2-H18/2DR3A?
- The AUX AM2-H18/2DR3A is rated at up to 22.0 SEER2 and 12.3 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
- Is the AUX AM2-H18/2DR3A good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 14,500 BTU/h at 5°F with a COP of 2.00, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
- How much does the AUX AM2-H18/2DR3A cost to run per year?
- At its rated efficiency it costs about $380-$1,113 a year in electricity in large U.S. cities, depending on climate and local rates - for example $482 in Phoenix and $940 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Is the AUX AM2-H18/2DR3A the same as the DELLA 048-MS-18K-MODU?
- Yes, as far as the certified ratings go. ENERGY STAR lists 5 model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
- What refrigerant does the AUX AM2-H18/2DR3A use?
- It uses R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 18,000 BTU models
- American Standard 4TXK3818A10NU · cold climate22.0 SEER2 · 10.0 HSPF2
- Panasonic CU-3E19RBU-5 · cold climate22.0 SEER2 · 10.1 HSPF2
- Blueridge BMKH1824/O · cold climate22.0 SEER2 · 10.0 HSPF2
- Mitsubishi Electric MUFZ-KJ18NAHZ22.0 SEER2 · 10.3 HSPF2
- Hisense AMW2-18U3TJA · cold climate22.0 SEER2 · 10.0 HSPF2
- Mitsubishi Electric SUZ-KA18NAH22.0 SEER2 · 10.4 HSPF2
- Hitachi RAS-2.0PNNBDH1 · cold climate22.0 SEER2 · 10.0 HSPF2
- Fujitsu AOUH18KWAS2 · cold climate22.0 SEER2 · 10.5 HSPF2
See all 465 18,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 25, 2026. How we use the data.