HVAC Rated

18,000 BTU mini-split heat pump · M-Series

AUX ASW-H18E3B2/*R3DI-D2

Very good cooling efficiency and average heating efficiency for a 18,000 BTU mini-split heat pump, and certified for cold climates.

Ranks #32 of 465 18,000 BTU mini-splits for cooling efficiency, and costs about $428 a year to run in a mixed climate like Atlanta.

SEER2
25.0 Cooling efficiency over a season
Very good · beats 83%
HSPF2
10.5 Heating efficiency over a season
Average · beats 61%
EER2
14.0 Cooling efficiency on a 95°F day
Very good · beats 82%
Heat at 5°F
15,000 BTU/h82% of its 47°F output
Very good · beats 83%

A good fit if…

  • You want low cooling bills - its SEER2 beats 83% of mini-splits.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 15,000 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications18,000 BTU, R-32
General
BrandAUX
Also sold asAUFIT
Outdoor unit modelASW-H18E3B2/*R3DI-D2
SeriesM-Series
TypeMini-split heat pump
Nominal size18,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-32
Connected (smart) capableNo
On the market sinceFebruary 8, 2026
Last certifiedAugust 20, 2026
Cooling
SEER2Seasonal efficiency, higher is better25.0 (range 25.0)
EER2Efficiency at 95°F outdoors14.0
Cooling capacity18,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better10.5
Capacity at 47°F18,200 BTU/h
Capacity at 17°F16,400 BTU/h
Capacity at 5°F15,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.25
ENERGY STAR cold climateYes
Heating output as it gets colder82% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with ASW-H18E3B2/*R3DI-D2 at the standard test temperatures, in BTU/h:

Certified matchups2 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
ASW-H18E3B2/*R3DI-D2 · cold climate25.014.010.515,000215218928
ASW-H18E3B2/*R3DI-D2 AUFIT · cold climate25.014.010.515,000217902887
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the AUX ASW-H18E3B2/*R3DI-D2: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

  • AUX ASW-H18E3B2/**R3DI-D2
Yearly running cost in 10 large cities$341-$1,058

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the AUX ASW-H18E3B2/*R3DI-D2?
The AUX ASW-H18E3B2/*R3DI-D2 is rated at up to 25.0 SEER2 and 14.0 EER2 for cooling and up to 10.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
Is the AUX ASW-H18E3B2/*R3DI-D2 good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 15,000 BTU/h at 5°F with a COP of 2.25, so it is still 2.3 times as efficient as electric resistance heat at that temperature.
How much does the AUX ASW-H18E3B2/*R3DI-D2 cost to run per year?
At its rated efficiency it costs about $341-$1,058 a year in electricity in large U.S. cities, depending on climate and local rates - for example $440 in Phoenix and $900 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the AUX ASW-H18E3B2/*R3DI-D2 the same as the AUX ASW-H18E3B2/**R3DI-D2?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the AUX ASW-H18E3B2/*R3DI-D2?
ENERGY STAR lists 2 certified combinations for this outdoor unit. The highest-rated ones use ASW-H18E3B2/*R3DI-D2, AUFIT ASW-H18E3B2/*R3DI-D2.
What refrigerant does the AUX ASW-H18E3B2/*R3DI-D2 use?
It uses R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $448/yrYou save $484/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump AUX ASW-H18E3B2/*R3DI-D2
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$448
Current system, per year
$931
You save per year
$484
Payback
14.5 years
Net after 10 years
-$2,162

Cooling $253Heating $194Electricity used: 2,797 kWhSaved vs. a minimum-efficiency heat pump: $267

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 18,000 BTU models

See all 465 18,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of August 20, 2026. How we use the data.