HVAC Rated

4-ton central heat pump · BHP17L SERIES

Blueridge BHP17L48P-**A

Below average cooling and heating efficiency for a 4-ton central heat pump, but not rated for cold climates.

Ranks #272 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,502 a year to run in a mixed climate like Atlanta.

SEER2
15.6 Cooling efficiency over a season
Below average · beats 17%
HSPF2
8.3 Heating efficiency over a season
Below average · beats 30%
EER2
12.5 Cooling efficiency on a 95°F day
Very good · beats 80%
Heat at 5°F
25,600 BTU/h57% of its 47°F output
Excellent · beats 94%

A good fit if…

  • You want a choice of indoor units - 85 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications4 ton, R-410A
General
BrandBlueridge
Outdoor unit modelBHP17L48P-**A
SeriesBHP17L SERIES
TypeCentral heat pump
Nominal size4 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceOctober 1, 2022
Last certifiedOctober 27, 2025
Cooling
SEER2Seasonal efficiency, higher is better15.6 (range 15.2-15.6)
EER2Efficiency at 95°F outdoors12.5-13.0
Cooling capacity46,000-48,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.0-8.3
Capacity at 47°F44,500-47,000 BTU/h
Capacity at 17°F30,000-31,600 BTU/h
Capacity at 5°F24,200-25,600 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.18-2.38
ENERGY STAR cold climateNo
Heating output as it gets colder57% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with BH1P51C*+TDR+TXV at the standard test temperatures, in BTU/h:

Certified matchups85 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 85 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
BH1P51C*+TDR+TXVBG801UH090CE2015.612.58.325,200211737251
BC751HCT-0*+TDRBG801UH090CE2015.612.58.325,200214713591
BC4X60C+TDRBG801UH090CE2015.613.08.125,200210441406
BC4X49C+TDRBG801UH090CE2015.613.08.125,000210441395
BC1P49C+TDR+TXVBG801UH090CE2015.613.08.125,000210325142
BC1P60C+TDR+TXVBG801UH090CE2015.613.08.125,200210325165
BC760CCT-0*+TDRBG801UH090CE2015.613.08.125,200214713628
BC749CCT-0*+TDRBG801UH090CE2015.613.08.125,000214713612
BC1P60C+TDR+TXVBG921UH110CE2015.412.58.325,400210325170
BC4X60C+TDRBG801UH110CE2015.412.58.325,400210441407
BC4X60C+TDRBG921UH110CE2015.412.58.325,400210441410
BC4X60C+TDRBG802UH110CV2015.412.58.325,400210441413
BC1P60C+TDR+TXVBG801UH110CE2015.412.58.325,400210325168
BC1P60C+TDR+TXVBG802UH110CV2015.412.58.325,400210325180
BH1P51C*+TDR+TXVBG961UH110CE2015.412.58.325,400211737293
BH1P51C*+TDR+TXVBG921UH110CE1615.412.58.325,600211737277
BC760CCT-0*+TDRBG801UH110CE2015.412.58.325,400214713629
BC751HCT-0*+TDRBG921UH110CE1615.412.58.325,600214713594
BC751HCT-0*+TDRBG961UH110CE2015.412.58.325,400214713596
BC760CCT-0*+TDRBG921UH110CE2015.412.58.325,400214713632
BC760CCT-0*+TDRBG802UH110CV2015.412.58.325,400214713635
BC1P49C+TDR+TXVBG921UH110CE2015.412.58.125,000210325144
BC1P48B+TDR+TXVBG801UH090CE2015.412.58.124,400210325120
BC1P48C+TDR+TXVBG801UH090CE2015.412.58.124,400210441364
BC4X48C+TDRBG921UH110CE2015.412.58.124,400210441388
BC4X48C+TDRBG801UH090CE2015.412.58.124,400210441384
BC4X49C+TDRBG921UH110CE2015.412.58.125,000210441399
BC4X60C+TDRBG961UH110CE2015.412.58.125,200210441412
BC4X60C+TDRBG921UH110CE1615.412.58.125,200210441409
BC4X60C+TDRBG961UH090CE1615.412.58.125,400210441411
BC1P48C+TDR+TXVBG921UH110CE2015.412.58.124,400210441368
BC1P48B+TDR+TXVBG921UH110CE2015.412.58.124,400210325122
BC1P60C+TDR+TXVBG921UH110CE1615.412.58.125,200210325174
BC1P60C+TDR+TXVBG961UH090CE1615.412.58.125,400210325176
BC1P60C+TDR+TXVBG961UH110CE2015.412.58.125,200210325167
BC749CCT-0*+TDRBG921UH110CE2015.412.58.125,000214713616
BC748CCT-0*+TDRBG801UH090CE2015.412.58.124,400214713604
BC748CCT-0*+TDRBG921UH110CE2015.412.58.124,400214713608
BC760CCT-0*+TDRBG921UH110CE1615.412.58.125,200214713631
BC760CCT-0*+TDRBG961UH090CE1615.412.58.125,400214713633
BC760CCT-0*+TDRBG961UH110CE2015.412.58.125,200214713634
BE5V48MA4X-15.212.58.324,200210325110
BH1P51C*+TDR+TXVBG921UH090CE1615.212.58.325,600211737269
BH1P51C*+TDR+TXVBG801UH110CE2015.212.58.325,600211737260
BH1P51C*+TDR+TXVBG802UH110CV2015.212.58.325,600211737308
BH1P51C*+TDR+TXVBG921UH110CE2015.212.58.325,600211737285
BC751HCT-0*+TDRBG801UH110CE2015.212.58.325,600214713592
BC751HCT-0*+TDRBG921UH090CE1615.212.58.325,600214713593
BC751HCT-0*+TDRBG921UH110CE2015.212.58.325,600214713595
BC751HCT-0*+TDRBG802UH110CV2015.212.58.325,600214713597
BAH7V48PT-0-15.212.58.324,200214866135
BC1P48B+TDR+TXVBG801UH090BE1615.212.58.124,200210325112
BC1P49C+TDR+TXVBG801UH110CE2015.212.58.125,600210325147
BC1P49C+TDR+TXVBG921UH110CE1615.212.58.125,400210325151
BC1P49C+TDR+TXVBG961UH110CE2015.212.58.125,400210325145
BC4X48C+TDRBG961UH110CE2015.212.58.124,200210441390
BC1P48C+TDR+TXVBG921UH110CE1615.212.58.124,400210441367
BC4X49C+TDRBG961UH110CE2015.212.58.125,400210441401
BC4X49C+TDRBG802UH110CV2015.212.58.125,600210441402
BC4X49C+TDRBG801UH110CE2015.212.58.125,600210441396
Yearly running cost in 10 large cities$1,431-$3,509

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Blueridge BHP17L48P-**A?
The Blueridge BHP17L48P-**A is rated at up to 15.6 SEER2 and 12.5 EER2 for cooling and up to 8.3 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 85 certified matchups SEER2 ranges from 15.2-15.6.
Is the Blueridge BHP17L48P-**A good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 4-ton model.
How much does the Blueridge BHP17L48P-**A cost to run per year?
At its rated efficiency it costs about $1,431-$3,509 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,728 in Phoenix and $2,895 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Blueridge BHP17L48P-**A?
ENERGY STAR lists 85 certified combinations for this outdoor unit. The highest-rated ones use BH1P51C*+TDR+TXV, BC751HCT-0*+TDR, BC4X60C+TDR.
What refrigerant does the Blueridge BHP17L48P-**A use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,690/yrYou save $736/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Blueridge BHP17L48P-**A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,690
Current system, per year
$2,426
You save per year
$736
Payback
24.5 years
Net after 10 years
-$10,644

Cooling $1,083Heating $607Electricity used: 10,564 kWhSaved vs. a minimum-efficiency heat pump: $163

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 4 ton models

See all 319 4 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 27, 2025. How we use the data.