24,000 BTU mini-split heat pump · XS4
Blueridge BXS6Z24UC0
Excellent cooling efficiency and average heating efficiency for a 24,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #2 of 430 24,000 BTU mini-splits for cooling efficiency, and costs about $557 a year to run in a mixed climate like Atlanta.
- SEER2
- 27.0 Cooling efficiency over a seasonExcellent · beats 94%
- HSPF2
- 10.0 Heating efficiency over a seasonAverage · beats 43%
- EER2
- 14.0 Cooling efficiency on a 95°F dayVery good · beats 80%
- Heat at 5°F
- 24,000 BTU/h100% of its 47°F outputBelow average · beats 9%
A good fit if…
- You want low cooling bills - its SEER2 beats 94% of mini-splits.
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 24,000 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | Blueridge |
| Also sold as | GREE, Kinghome, ECO AC, Willis, Ouellet |
| Outdoor unit model | BXS6Z24UC0 |
| Series | XS4 |
| Type | Mini-split heat pump |
| Nominal size | 24,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-32 |
| Connected (smart) capable | No |
| On the market since | May 13, 2025 |
| Last certified | November 20, 2025 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 27.0 (range 27.0) |
| EER2Efficiency at 95°F outdoors | 14.0 |
| Cooling capacity | 22,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 10.0 |
| Capacity at 47°F | 24,000 BTU/h |
| Capacity at 17°F | 23,000 BTU/h |
| Capacity at 5°F | 24,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.80 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with BXS6Z24WM0 at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| BXS6Z24WM0 BLUERIDGE · cold climate | 27.0 | 14.0 | 10.0 | 24,000 | 217448548 |
Same unit, other model numbers
These model numbers have exactly the same certified ratings and matchups as the Blueridge BXS6Z24UC0: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.
Yearly running cost in 10 large cities
- Phoenix, AZ$532/yr
- Miami, FL$389/yr
- Houston, TX$479/yr
- Atlanta, GA$557/yr
- Los Angeles, CA$559/yr
- New York, NY$1,422/yr
- Chicago, IL$1,171/yr
- Denver, CO$988/yr
- Seattle, WA$618/yr
- Minneapolis, MN$1,228/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Blueridge BXS6Z24UC0?
- The Blueridge BXS6Z24UC0 is rated at up to 27.0 SEER2 and 14.0 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
- Is the Blueridge BXS6Z24UC0 good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 24,000 BTU/h at 5°F with a COP of 1.80, so it is still 1.8 times as efficient as electric resistance heat at that temperature.
- How much does the Blueridge BXS6Z24UC0 cost to run per year?
- At its rated efficiency it costs about $389-$1,422 a year in electricity in large U.S. cities, depending on climate and local rates - for example $532 in Phoenix and $1,228 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Is the Blueridge BXS6Z24UC0 the same as the GREE GS24HP230V1RYO?
- Yes, as far as the certified ratings go. ENERGY STAR lists 7 model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
- Which indoor units work with the Blueridge BXS6Z24UC0?
- ENERGY STAR lists 1 certified combination for this outdoor unit. The highest-rated one uses BLUERIDGE BXS6Z24WM0.
- What refrigerant does the Blueridge BXS6Z24UC0 use?
- It uses R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 24,000 BTU models
- SLIMAIR SHC24VH2AG · cold climate27.5 SEER2 · 14.5 HSPF2
- TOSOT TW24HAY32A1DO · cold climate27.0 SEER2 · 10.0 HSPF2
- TOSOT TW24WH29D6DO · cold climate27.0 SEER2 · 10.0 HSPF2
- TOSOT TWH24AD32AO · cold climate27.0 SEER2 · 10.0 HSPF2
- TOSOT TWH24AR32AO · cold climate27.0 SEER2 · 10.0 HSPF2
- DELLA 048-TPH-MODU-1D4 · cold climate26.5 SEER2 · 10.5 HSPF2
- NOVAIR LEA27-MZ-LCT- 454-O · cold climate26.5 SEER2 · 10.5 HSPF2
- NOVAIR LEA28MZ-4P-454-O · cold climate26.5 SEER2 · 10.5 HSPF2
See all 430 24,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of November 20, 2025. How we use the data.