HVAC Rated

4-ton central heat pump · 2-STAGE 18 SEER HP

Bryant 248TAN048**AA

Average cooling efficiency and below average heating efficiency for a 4-ton central heat pump, but not rated for cold climates.

Ranks #99 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,498 a year to run in a mixed climate like Atlanta.

SEER2
18.0 Cooling efficiency over a season
Average · beats 66%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
13.0 Cooling efficiency on a 95°F day
Very good · beats 89%
Heat at 5°F
26,600 BTU/h50% of its 47°F output
Excellent · beats 90%

A good fit if…

  • You want a choice of indoor units - 417 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications4 ton, R-454B
General
BrandBryant
Outdoor unit model248TAN048**AA
Series2-STAGE 18 SEER HP
TypeCentral heat pump
Nominal size4 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceNovember 4, 2024
Last certifiedSeptember 16, 2026
Cooling
SEER2Seasonal efficiency, higher is better18.0 (range 15.2-18.0)
EER2Efficiency at 95°F outdoors11.7-13.5
Cooling capacity45,500-50,500 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.5
Capacity at 47°F48,500-52,500 BTU/h
Capacity at 17°F30,000-32,600 BTU/h
Capacity at 5°F23,800-26,600 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.06-2.32
ENERGY STAR cold climateNo
Heating output as it gets colder50% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FT5BD6021X at the standard test temperatures, in BTU/h:

Certified matchups417 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 417 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
FT5BD6021X-18.013.08.525,800218695441
FT5ANBD60L-18.013.58.124,600215560707
FG5ANBD60L-18.013.58.124,600215560708
PF5TNBD60L-18.013.58.124,600215560709
CVAVA6121XMA82*SB66110V21***17.512.58.524,800215625025
CVAVA6121XMA83*SB60080M21***17.513.08.524,400215625057
CVAVA6121XMA83*SB60100M21***17.512.58.525,000215625076
CVAVA6121XMA88*TB60090C21***17.512.08.525,200215625109
CVAVA6121XMA88*TB60110C21***17.512.58.525,000215625123
CVAVA6124XMA935SB66100M21***17.512.58.525,000215625657
CVAVA6121XMA926TC66100V21***17.512.58.524,600215625369
CVAVA6124XMA82*SB66110V21***17.512.58.525,000215625395
CVAVA6124XMA82*SB66135V24***17.512.58.525,200215625408
CVAVA6124XMA88*TB66135C24***17.512.58.524,800215625468
CVAVA6124XMA82*TB66110V21***17.512.58.524,800215625498
CVAVA6124XMA82*TB66135V24***17.512.58.525,000215625516
CVAVA6124XMA926TC66100V21***17.512.58.524,800215625749
CVAVA6121XMA927TA66100V21***17.512.58.524,600215722399
CVAVA6124XMA927TA66100V21***17.512.58.524,800215722516
CVAMA4921XMA83*SB60080M21***17.512.58.124,400215623310
CVAMA6021XMA926TC66100V21***17.512.58.124,400215624034
CVAMA6021XMA83*SB60080M21***17.512.58.124,400215623708
CVAVA4924XMA83*SB60080M21***17.512.58.124,600215624466
CVAVA6021XMA926TC66100V21***17.512.58.124,400215624999
CVAVA6121XMA83*SB48060M17***17.512.08.125,000215625038
CVAVA6121XMA82*TB66110V21***17.512.58.124,600215625153
CVAVA6121XMA935SB66100M21***17.512.58.124,400215625291
FT5BD4821X-17.512.58.125,400218695424
CVAMA6021XMA927TA66100V21***17.512.58.024,400215722093
CVAVA6021XMA927TA66100V21***17.512.58.024,400215722296
CVAVA6121XMA83*CB60080C21***17.512.58.024,800215722309
CVAVA6124XMA83*CB60080C21***17.512.58.024,600215722412
CVAVA4924XMA926TC66100V21***17.012.08.524,800215624705
CVAVA6121XMA82*SB60090V21***17.012.58.524,800215625012
CVAVA6121XMA82*TB60090V21***17.012.58.524,800215625137
CVAVA6124XMA83*SB60100M21***17.012.58.525,000215625421
CVAVA6124XMA926SB66120V24***17.012.08.525,200215625606
CVAVA6121XMA935SB60100M21***17.012.58.524,800215625272
CVAVA6121XMA986TD60080C21***17.012.58.525,200215625305
CVAVA6124XMA82*SB60090V21***17.012.58.525,000215625382
CVAVA6124XMA88*TB60090C21***17.012.58.525,000215625454
CVAVA6124XMA82*TB60090V21***17.012.58.525,000215625482
CVAVA6124XMA926TC60080V21***17.012.08.525,600215625713
CVAMA4821XMA83*SB60080M21***17.012.08.124,000215622953
CVAMA4921XMA82*SB60090V21***17.012.08.125,000215623265
CVAMA4921XMA82*SB66110V21***17.012.58.124,600215623278
CVAMA4921XMA83*SB48060M17***17.012.08.125,000215623291
CVAMA4921XMA83*SB60100M21***17.012.08.124,800215623329
CVAMA4921XMA88*TB60090C21***17.012.08.125,200215623362
CVAMA4921XMA88*TB60110C21***17.012.08.125,000215623376
CVAMA4921XMA82*TB60090V21***17.012.08.125,000215623390
CVAMA4921XMA82*TB66110V21***17.012.58.124,800215623406
CVAMA4921XMA987MC66100C21***17.012.08.125,200215623480
CVAMA4921XMA935SB60100M21***17.012.08.125,200215623539
CVAMA4921XMA935SB66100M21***17.012.58.124,800215623558
CVAMA4921XMA986TD66100C21***17.012.08.125,200215623586
CVAVA4821XMA83*SB60080M21***17.012.08.124,000215624093
CVAMA4921XMA926TC66100V21***17.012.58.124,400215623636
CVAMA6021XMA83*CA60100C21***17.012.08.125,200215623649
CVAMA6021XMA82*SB60090V21***17.012.08.124,600215623663
Yearly running cost in 10 large cities$1,258-$3,646

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Bryant 248TAN048**AA?
The Bryant 248TAN048**AA is rated at up to 18.0 SEER2 and 13.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 417 certified matchups SEER2 ranges from 15.2-18.0.
Is the Bryant 248TAN048**AA good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 4-ton model.
How much does the Bryant 248TAN048**AA cost to run per year?
At its rated efficiency it costs about $1,258-$3,646 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,589 in Phoenix and $3,076 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Bryant 248TAN048**AA?
ENERGY STAR lists 417 certified combinations for this outdoor unit. The highest-rated ones use FT5BD6021X, FT5ANBD60L, FG5ANBD60L.
What refrigerant does the Bryant 248TAN048**AA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,597/yrYou save $910/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Bryant 248TAN048**AA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,597
Current system, per year
$2,508
You save per year
$910
Payback
19.8 years
Net after 10 years
-$8,898

Cooling $939Heating $659Electricity used: 9,984 kWhSaved vs. a minimum-efficiency heat pump: $331

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 4 ton models

See all 319 4 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 16, 2026. How we use the data.