2.5-ton central heat pump · 15 SEER2 HP
Bryant GH5SAN530**AA
Below average cooling and heating efficiency for a 2.5-ton central heat pump, but not rated for cold climates.
Ranks #173 of 199 2.5 ton central heat pumps for cooling efficiency, and costs about $963 a year to run in a mixed climate like Atlanta.
- SEER2
- 15.2 Cooling efficiency over a seasonBelow average · beats 6%
- HSPF2
- 8.1 Heating efficiency over a seasonBelow average · beats 20%
- EER2
- 12.0 Cooling efficiency on a 95°F dayAverage · beats 64%
- Heat at 5°F
- 13,900 BTU/h48% of its 47°F outputVery good · beats 83%
A good fit if…
- You want a choice of indoor units - 13 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- Cooling cost matters most - its SEER2 is below average for central heat pumps.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- Comfort and noise matter - a single-stage compressor runs only full-on or off.
Details
Specifications
| General | |
|---|---|
| Brand | Bryant |
| Also sold as | Carrier |
| Outdoor unit model | GH5SAN530**AA |
| Series | 15 SEER2 HP |
| Type | Central heat pump |
| Nominal size | 2.5 ton |
| CompressorVariable-speed units run longer at low power | Single stage |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | January 1, 2024 |
| Last certified | February 11, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 15.2 (range 15.2) |
| EER2Efficiency at 95°F outdoors | 12.0-12.5 |
| Cooling capacity | 27,600-30,200 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-8.1 |
| Capacity at 47°F | 28,000-29,000 BTU/h |
| Capacity at 17°F | 17,200-17,800 BTU/h |
| Capacity at 5°F | 13,500-13,900 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.96-2.26 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FMA5X36**AL at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| FMA5X36**AL | - | 15.2 | 12.0 | 8.1 | 13,900 | 214424197 |
| FMA5X36**AL | - | 15.2 | 12.0 | 8.1 | 13,900 | 214424200 |
| FMA5X30**AL | - | 15.2 | 12.5 | 8.1 | 13,900 | 214424165 |
| FMA5X30**AL | - | 15.2 | 12.5 | 8.1 | 13,900 | 214424168 |
| CVAVA4224XMA | 58SU*B080M21**20 | 15.2 | 12.0 | 7.8 | 13,500 | 214136791 |
| CVAVA4224XMA | 83*SB60080M21*** | 15.2 | 12.0 | 7.8 | 13,500 | 214136794 |
| FJ5AN*C42L | - | 15.2 | 12.0 | 7.8 | 13,500 | 214179470 |
| FJ5AN*C42L | - | 15.2 | 12.0 | 7.8 | 13,500 | 214179475 |
| PF5MN*C42L | - | 15.2 | 12.0 | 7.8 | 13,500 | 214179476 |
| F55AA*C42L | - | 15.2 | 12.0 | 7.8 | 13,500 | 216463892 |
| F55AA*C42L | - | 15.2 | 12.0 | 7.8 | 13,500 | 216463895 |
| CVAVA4224XMA | 58S(B,C)*B110M24**20 | 15.2 | 12.0 | 7.8 | 13,500 | 214136566 |
| CVAVA4224XMA | 8(0,1)*SB60110M24*** | 15.2 | 12.0 | 7.8 | 13,500 | 214136569 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,087/yr
- Miami, FL$895/yr
- Houston, TX$973/yr
- Atlanta, GA$963/yr
- Los Angeles, CA$932/yr
- New York, NY$2,275/yr
- Chicago, IL$1,842/yr
- Denver, CO$1,527/yr
- Seattle, WA$935/yr
- Minneapolis, MN$1,888/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Bryant GH5SAN530**AA?
- The Bryant GH5SAN530**AA is rated at up to 15.2 SEER2 and 12.0 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
- Is the Bryant GH5SAN530**AA good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2.5-ton model.
- How much does the Bryant GH5SAN530**AA cost to run per year?
- At its rated efficiency it costs about $895-$2,275 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,087 in Phoenix and $1,888 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Bryant GH5SAN530**AA?
- ENERGY STAR lists 13 certified combinations for this outdoor unit. The highest-rated ones use FMA5X36**AL, FMA5X30**AL, CVAVA4224XMA.
- What refrigerant does the Bryant GH5SAN530**AA use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 2.5 ton models
- Arcoaire N5H5S30*K*AAA15.2 SEER2 · 8.1 HSPF2
- Carrier 27SCA530A**3015.2 SEER2 · 8.1 HSPF2
- Arcoaire H5H6S30*K*AAA15.2 SEER2 · 8.1 HSPF2
- Comfortmaker C5H6S30*K*AAA15.2 SEER2 · 8.1 HSPF2
- Ameristar E4HL5036A1000A · cold climate15.2 SEER2 · 8.1 HSPF2
- EVCON RHP15030B2115.2 SEER2 · 8.1 HSPF2
- Ameristar E4HL5030A1000A · cold climate15.2 SEER2 · 8.1 HSPF2
- Grandaire W5H5S30*K*AAA15.2 SEER2 · 8.1 HSPF2
See all 199 2.5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of February 11, 2026. How we use the data.