48,000 BTU mini-split heat pump · 45M Series
Carrier 37MBHAQ58AA3
Below average cooling efficiency and average heating efficiency for a 48,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #126 of 146 48,000 BTU mini-splits for cooling efficiency, and costs about $1,514 a year to run in a mixed climate like Atlanta.
- SEER2
- 18.1 Cooling efficiency over a seasonBelow average · beats 5%
- HSPF2
- 10.7 Heating efficiency over a seasonAverage · beats 68%
- EER2
- 9.0 Cooling efficiency on a 95°F dayBelow average · beats 1%
- Heat at 5°F
- 54,000 BTU/h90% of its 47°F outputAverage · beats 67%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 54,000 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
- You want a choice of indoor units - 15 certified pairings.
Think twice if…
- Cooling cost matters most - its SEER2 is below average for mini-splits.
Details
Specifications
| General | |
|---|---|
| Brand | Carrier |
| Also sold as | Bryant, Payne, WeatherMaker, Midea |
| Outdoor unit model | 37MBHAQ58AA3 |
| Series | 45M Series |
| Type | Mini-split heat pump |
| Nominal size | 48,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | November 15, 2018 |
| Last certified | March 13, 2025 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 18.1 (range 15.4-18.1) |
| EER2Efficiency at 95°F outdoors | 9.0-10.2 |
| Cooling capacity | 54,000-55,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.2-10.7 |
| Capacity at 47°F | 59,000-60,000 BTU/h |
| Capacity at 17°F | 41,000-45,000 BTU/h |
| Capacity at 5°F | 53,000-54,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.91-2.10 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 45MCFAQ58XA3 at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| 45MCFAQ58XA3 CARRIER · cold climate | 18.1 | 9.0 | 10.7 | 54,000 | 215323848 |
| 45MCFAQ58XA3 BRYANT · cold climate | 18.1 | 9.0 | 10.7 | 54,000 | 215323909 |
| 45MCFAQ58XA3 PAYNE · cold climate | 18.1 | 9.0 | 10.7 | 54,000 | 215323970 |
| 45MCFAQ58XA3 Weathermaker · cold climate | 18.1 | 9.0 | 10.7 | 54,000 | 215324031 |
| 45MCFAQ58XA3 MIDEA · cold climate | 18.1 | 9.0 | 10.7 | 54,000 | 215324092 |
| 45MBDAQ58XH3 CARRIER · cold climate | 15.9 | 10.2 | 10.4 | 53,500 | 215323849 |
| 45MBDAQ58XH3 BRYANT · cold climate | 15.9 | 10.2 | 10.4 | 53,500 | 215323910 |
| 45MBDAQ58XH3 PAYNE · cold climate | 15.9 | 10.2 | 10.4 | 53,500 | 215323971 |
| 45MBDAQ58XH3 Weathermaker · cold climate | 15.9 | 10.2 | 10.4 | 53,500 | 215324032 |
| 45MBDAQ58XH3 MIDEA · cold climate | 15.9 | 10.2 | 10.4 | 53,500 | 215324093 |
| 45MBAAQ60XA3 · cold climate | 15.4 | 10.0 | 9.2 | 53,000 | 215318771 |
| 45MBAAQ60XA3 · cold climate | 15.4 | 10.0 | 9.2 | 53,000 | 215318799 |
| 45MBAAQ60XA3 · cold climate | 15.4 | 10.0 | 9.2 | 53,000 | 215318855 |
| 45MBAAQ60XA3 · cold climate | 15.4 | 10.0 | 9.2 | 53,000 | 215318883 |
| 45MBAAQ60XA3 · cold climate | 15.4 | 10.0 | 9.2 | 53,000 | 215318827 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,703/yr
- Miami, FL$1,399/yr
- Houston, TX$1,526/yr
- Atlanta, GA$1,514/yr
- Los Angeles, CA$1,467/yr
- New York, NY$3,582/yr
- Chicago, IL$2,901/yr
- Denver, CO$2,406/yr
- Seattle, WA$1,474/yr
- Minneapolis, MN$2,975/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Carrier 37MBHAQ58AA3?
- The Carrier 37MBHAQ58AA3 is rated at up to 18.1 SEER2 and 9.0 EER2 for cooling and up to 10.7 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 15 certified matchups SEER2 ranges from 15.4-18.1.
- Is the Carrier 37MBHAQ58AA3 good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 54,000 BTU/h at 5°F with a COP of 2.10, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
- How much does the Carrier 37MBHAQ58AA3 cost to run per year?
- At its rated efficiency it costs about $1,399-$3,582 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,703 in Phoenix and $2,975 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Carrier 37MBHAQ58AA3?
- ENERGY STAR lists 15 certified combinations for this outdoor unit. The highest-rated ones use CARRIER 45MCFAQ58XA3, BRYANT 45MCFAQ58XA3, PAYNE 45MCFAQ58XA3.
- What refrigerant does the Carrier 37MBHAQ58AA3 use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 48,000 BTU models
- Arcoaire D5CLHAH58AAK · cold climate18.1 SEER2 · 10.7 HSPF2
- MDV MOE30-60HFN10-M2X · cold climate18.1 SEER2 · 10.7 HSPF2
- Fujitsu AOUH48KUAS1 · cold climate18.2 SEER2 · 10.2 HSPF2
- Mitsubishi Electric SUZ-AK48NLHZ · cold climate18.1 SEER2 · 8.5 HSPF2
- LG KUSUB601A · cold climate18.5 SEER2 · 9.0 HSPF2
- ECO-AIR EDSO-48H · cold climate18.0 SEER2 · 11.0 HSPF2
- LG KUSUB481A · cold climate18.5 SEER2 · 9.0 HSPF2
- Mainline ML60HP230LCMH-O · cold climate18.0 SEER2 · 10.7 HSPF2
See all 146 48,000 BTU mini-splits, ranked