48,000 BTU mini-split heat pump · A-VHP Series
Comfort-Aire A-VHP556A-1
Average cooling and heating efficiency for a 48,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #43 of 146 48,000 BTU mini-splits for cooling efficiency, and costs about $1,311 a year to run in a mixed climate like Atlanta.
- SEER2
- 22.2 Cooling efficiency over a seasonAverage · beats 52%
- HSPF2
- 10.7 Heating efficiency over a seasonAverage · beats 68%
- EER2
- 12.0 Cooling efficiency on a 95°F dayBelow average · beats 25%
- Heat at 5°F
- 48,000 BTU/h85% of its 47°F outputAverage · beats 67%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 48,000 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | Comfort-Aire |
| Also sold as | Century |
| Outdoor unit model | A-VHP556A-1 |
| Series | A-VHP Series |
| Type | Mini-split heat pump |
| Nominal size | 48,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | November 11, 2024 |
| Last certified | May 28, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 22.2 (range 20.0-22.2) |
| EER2Efficiency at 95°F outdoors | 11.7-12.0 |
| Cooling capacity | 51,000-53,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 10.5-10.7 |
| Capacity at 47°F | 55,000 BTU/h |
| Capacity at 17°F | 47,000-50,000 BTU/h |
| Capacity at 5°F | 47,000-48,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.00-2.10 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| - COMFORT-AIRE · cold climate | 22.2 | 12.0 | 10.5 | 47,000 | 216097136 |
| - Comfort Aire · cold climate | 22.2 | 12.0 | 10.5 | 47,000 | 217101923 |
| - CENTURY · cold climate | 22.2 | 12.0 | 10.5 | 47,000 | 218425171 |
| - COMFORT-AIRE · cold climate | 21.1 | 11.9 | 10.6 | 47,500 | 216097138 |
| - Comfort Aire · cold climate | 21.1 | 11.9 | 10.6 | 47,500 | 217101925 |
| - CENTURY · cold climate | 21.1 | 11.9 | 10.6 | 47,500 | 218425173 |
| - COMFORT-AIRE · cold climate | 20.0 | 11.7 | 10.7 | 48,000 | 216097137 |
| - Comfort Aire · cold climate | 20.0 | 11.7 | 10.7 | 48,000 | 217101924 |
| - CENTURY · cold climate | 20.0 | 11.7 | 10.7 | 48,000 | 218425172 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,394/yr
- Miami, FL$1,104/yr
- Houston, TX$1,251/yr
- Atlanta, GA$1,311/yr
- Los Angeles, CA$1,286/yr
- New York, NY$3,189/yr
- Chicago, IL$2,600/yr
- Denver, CO$2,170/yr
- Seattle, WA$1,340/yr
- Minneapolis, MN$2,689/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Comfort-Aire A-VHP556A-1?
- The Comfort-Aire A-VHP556A-1 is rated at up to 22.2 SEER2 and 12.0 EER2 for cooling and up to 10.7 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 9 certified matchups SEER2 ranges from 20.0-22.2.
- Is the Comfort-Aire A-VHP556A-1 good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 48,000 BTU/h at 5°F with a COP of 2.10, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
- How much does the Comfort-Aire A-VHP556A-1 cost to run per year?
- At its rated efficiency it costs about $1,104-$3,189 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,394 in Phoenix and $2,689 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- What refrigerant does the Comfort-Aire A-VHP556A-1 use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 48,000 BTU models
- MDV M6OE31-53HFN10-M1X · cold climate22.3 SEER2 · 10.7 HSPF2
- MDV M6OE31-53HFN10-M1X-D · cold climate22.2 SEER2 · 10.7 HSPF2
- Bryant 37MGHAQ55FA3 · cold climate22.3 SEER2 · 10.7 HSPF2
- Midea MO6HX-H60B-2A · cold climate22.2 SEER2 · 10.7 HSPF2
- Arcoaire D5CMHAH55FAK · cold climate22.3 SEER2 · 10.7 HSPF2
- MRCOOL DIY-MULTI6-55HP230D-O · cold climate22.0 SEER2 · 10.6 HSPF2
- TOSHIBA CARRIER MCY-MAP0487HS-UL22.6 SEER2 · 10.3 HSPF2
- GREE GMV-V48WL/C-T(U) · cold climate22.0 SEER2 · 9.2 HSPF2
See all 146 48,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 28, 2026. How we use the data.