4-ton central heat pump · HSA14 Series
Comfort-Aire HSA1448S1-**A
Below average cooling and heating efficiency for a 4-ton central heat pump, but not rated for cold climates.
Ranks #314 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,582 a year to run in a mixed climate like Atlanta.
- SEER2
- 15.2 Cooling efficiency over a seasonBelow average · beats 6%
- HSPF2
- 8.0 Heating efficiency over a seasonBelow average · beats 12%
- EER2
- 12.8 Cooling efficiency on a 95°F dayVery good · beats 85%
- Heat at 5°F
- 24,200 BTU/h51% of its 47°F outputAverage · beats 67%
A good fit if…
- You want a choice of indoor units - 14 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- Cooling cost matters most - its SEER2 is below average for central heat pumps.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- Comfort and noise matter - a single-stage compressor runs only full-on or off.
Details
Specifications
| General | |
|---|---|
| Brand | Comfort-Aire |
| Also sold as | Century |
| Outdoor unit model | HSA1448S1-**A |
| Series | HSA14 Series |
| Type | Central heat pump |
| Nominal size | 4 ton |
| CompressorVariable-speed units run longer at low power | Single stage |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | October 1, 2024 |
| Last certified | October 27, 2025 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 15.2 (range 15.2) |
| EER2Efficiency at 95°F outdoors | 12.8 |
| Cooling capacity | 48,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-8.0 |
| Capacity at 47°F | 46,000-47,000 BTU/h |
| Capacity at 17°F | 29,800-30,200 BTU/h |
| Capacity at 5°F | 23,800-24,200 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.12-2.14 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 7E[C,U]60CX-**+TDR at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| 7E[C,U]60CX-**+TDR | GUH80C090C5MP* | 15.2 | 12.8 | 8.0 | 24,200 | 216372740 |
| 7E[C,U]60CX-**+TDR | GUH80C110C5MP* | 15.2 | 12.8 | 8.0 | 24,000 | 216372741 |
| 7E[C,U]60CX-**+TDR | GUH92C090C4MP* | 15.2 | 12.8 | 8.0 | 24,200 | 216372742 |
| 7E[C,U]60CX-**+TDR | GUH92C110C4MP* | 15.2 | 12.8 | 8.0 | 23,800 | 216372743 |
| 7E[C,U]60CX-**+TDR | GUH92C110C5MP* | 15.2 | 12.8 | 8.0 | 24,000 | 216372744 |
| 7E[C,U]60CX-**+TDR | GUH96C090C4MP* | 15.2 | 12.8 | 8.0 | 24,200 | 216372745 |
| 7E[C,U]60CX-**+TDR | GUH80C110C5MP* | 15.2 | 12.8 | 8.0 | 24,000 | 216372635 |
| 7E[C,U]60CX-**+TDR | GUH92C110C4MP* | 15.2 | 12.8 | 8.0 | 23,800 | 216372637 |
| 7E[C,U]60CX-**+TDR | GUH92C110C5MP* | 15.2 | 12.8 | 8.0 | 24,000 | 216372638 |
| 7E[C,U]60CX-**+TDR | GUH96C090C4MP* | 15.2 | 12.8 | 8.0 | 24,200 | 216372639 |
| 7E[C,U]60CX-**+TDR | GUH80C090C5MP* | 15.2 | 12.8 | 8.0 | 24,200 | 216372634 |
| 7E[C,U]60CX-**+TDR | GUH92C090C4MP* | 15.2 | 12.8 | 8.0 | 24,200 | 216372636 |
| 7E[C,U]49CX-**+TDR | GUH92C110C4MP* | 15.2 | 12.8 | 7.8 | 24,000 | 216372739 |
| 7E[C,U]49CX-**+TDR | GUH92C110C4MP* | 15.2 | 12.8 | 7.8 | 24,000 | 216372633 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,793/yr
- Miami, FL$1,480/yr
- Houston, TX$1,606/yr
- Atlanta, GA$1,582/yr
- Los Angeles, CA$1,530/yr
- New York, NY$3,728/yr
- Chicago, IL$3,017/yr
- Denver, CO$2,500/yr
- Seattle, WA$1,530/yr
- Minneapolis, MN$3,090/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Comfort-Aire HSA1448S1-**A?
- The Comfort-Aire HSA1448S1-**A is rated at up to 15.2 SEER2 and 12.8 EER2 for cooling and up to 8.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
- Is the Comfort-Aire HSA1448S1-**A good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 4-ton model.
- How much does the Comfort-Aire HSA1448S1-**A cost to run per year?
- At its rated efficiency it costs about $1,480-$3,728 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,793 in Phoenix and $3,090 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Comfort-Aire HSA1448S1-**A?
- ENERGY STAR lists 14 certified combinations for this outdoor unit. The highest-rated ones use 7E[C,U]60CX-**+TDR, 7E[C,U]49CX-**+TDR.
- What refrigerant does the Comfort-Aire HSA1448S1-**A use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 4 ton models
- TCL THH60HAI2NAF2U23 · cold climate15.2 SEER2 · 8.1 HSPF2
- Daikin DH5SEA4810A15.2 SEER2 · 7.8 HSPF2
- Sure SP15AZ48AJ2N · cold climate15.2 SEER2 · 8.1 HSPF2
- Friedrich FRP14AY48AJ2N15.2 SEER2 · 7.8 HSPF2
- Samsung AC048FCUDCG · cold climate15.2 SEER2 · 8.1 HSPF2
- Fujitsu FOP1548TJAYNA15.2 SEER2 · 7.8 HSPF2
- Rheem WP15AZ48AJ2N · cold climate15.2 SEER2 · 8.1 HSPF2
- Ruud RP14AY48AJ2N15.2 SEER2 · 7.8 HSPF2
See all 319 4 ton central heat pumps, ranked