HVAC Rated

2-ton central heat pump · AHU series

ComfortStar CPR24CD(O)

Average cooling efficiency and very good heating efficiency for a 2-ton central heat pump, and certified for cold climates.

Ranks #218 of 331 2 ton central heat pumps for cooling efficiency, and costs about $710 a year to run in a mixed climate like Atlanta.

SEER2
17.0 Cooling efficiency over a season
Average · beats 49%
HSPF2
9.8 Heating efficiency over a season
Very good · beats 79%
EER2
10.5 Cooling efficiency on a 95°F day
Below average · beats 17%
Heat at 5°F
19,400 BTU/h75% of its 47°F output
Very good · beats 76%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 19,400 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 79% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications2 ton, R-410A
General
BrandComfortStar
Also sold asKepler
Outdoor unit modelCPR24CD(O)
SeriesAHU series
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceJuly 13, 2023
Last certifiedJune 3, 2026
Cooling
SEER2Seasonal efficiency, higher is better17.0 (range 15.7-17.0)
EER2Efficiency at 95°F outdoors10.0-10.5
Cooling capacity24,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better9.2-9.8
Capacity at 47°F25,600-26,000 BTU/h
Capacity at 17°F21,000-22,000 BTU/h
Capacity at 5°F18,500-19,400 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.10-2.20
ENERGY STAR cold climateYes
Heating output as it gets colder75% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with AHU24-SG2 at the standard test temperatures, in BTU/h:

Certified matchups3 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
AHU24-SG2 · cold climate17.010.59.219,400208142953
ACP-24B · cold climate15.710.09.818,500213386512
UACP-24B · cold climate15.710.09.818,500213386524
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the ComfortStar CPR24CD(O): the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$662-$1,674

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the ComfortStar CPR24CD(O)?
The ComfortStar CPR24CD(O) is rated at up to 17.0 SEER2 and 10.5 EER2 for cooling and up to 9.8 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 3 certified matchups SEER2 ranges from 15.7-17.0.
Is the ComfortStar CPR24CD(O) good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 19,400 BTU/h at 5°F with a COP of 2.20, so it is still 2.2 times as efficient as electric resistance heat at that temperature.
How much does the ComfortStar CPR24CD(O) cost to run per year?
At its rated efficiency it costs about $662-$1,674 a year in electricity in large U.S. cities, depending on climate and local rates - for example $803 in Phoenix and $1,388 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the ComfortStar CPR24CD(O) the same as the Kepler AZPNS/24ROD?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the ComfortStar CPR24CD(O)?
ENERGY STAR lists 3 certified combinations for this outdoor unit. The highest-rated ones use AHU24-SG2, ACP-24B, UACP-24B.
What refrigerant does the ComfortStar CPR24CD(O) use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $790/yrYou save $474/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump ComfortStar CPR24CD(O)
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$790
Current system, per year
$1,264
You save per year
$474
Payback
19.0 years
Net after 10 years
-$4,258

Cooling $497Heating $293Electricity used: 4,934 kWhSaved vs. a minimum-efficiency heat pump: $184

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 3, 2026. How we use the data.