HVAC Rated

18,000 BTU mini-split heat pump · C series

ComfortStar CZP18CD(O)

Average cooling and heating efficiency for a 18,000 BTU mini-split heat pump, but not rated for cold climates.

Ranks #137 of 465 18,000 BTU mini-splits for cooling efficiency, and costs about $463 a year to run in a mixed climate like Atlanta.

SEER2
23.0 Cooling efficiency over a season
Average · beats 62%
HSPF2
10.7 Heating efficiency over a season
Average · beats 68%
EER2
12.5 Cooling efficiency on a 95°F day
Average · beats 44%
Heat at 5°F
13,100 BTU/h65% of its 47°F output
Excellent · beats 93%

A good fit if…

  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications18,000 BTU, R-410A
General
BrandComfortStar
Outdoor unit modelCZP18CD(O)
SeriesC series
TypeMini-split heat pump
Nominal size18,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceFebruary 2, 2020
Last certifiedMay 12, 2026
Cooling
SEER2Seasonal efficiency, higher is better23.0 (range 20.0-23.0)
EER2Efficiency at 95°F outdoors12.5
Cooling capacity16,000-18,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better10.0-10.7
Capacity at 47°F19,000-20,000 BTU/h
Capacity at 17°F12,000-12,800 BTU/h
Capacity at 5°F12,700-13,100 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.08-2.40
ENERGY STAR cold climateNo
Heating output as it gets colder65% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FPA-18 at the standard test temperatures, in BTU/h:

Certified matchups6 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
FPA-18 COMFORTSTAR23.012.510.013,000207658955
FPA-18 COMFORTSTAR23.012.510.013,000207658955
T1W18P COMFORTSTAR21.812.510.713,100214594915
TPA-18C COMFORTSTAR20.512.510.512,700207658945
TPA-18 COMFORTSTAR20.512.510.512,700207765975
CPA-18B COMFORTSTAR20.012.510.613,000207658932
Yearly running cost in 10 large cities$370-$1,143

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the ComfortStar CZP18CD(O)?
The ComfortStar CZP18CD(O) is rated at up to 23.0 SEER2 and 12.5 EER2 for cooling and up to 10.7 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 6 certified matchups SEER2 ranges from 20.0-23.0.
Is the ComfortStar CZP18CD(O) good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 18,000 BTU model.
How much does the ComfortStar CZP18CD(O) cost to run per year?
At its rated efficiency it costs about $370-$1,143 a year in electricity in large U.S. cities, depending on climate and local rates - for example $478 in Phoenix and $971 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the ComfortStar CZP18CD(O)?
ENERGY STAR lists 6 certified combinations for this outdoor unit. The highest-rated ones use COMFORTSTAR FPA-18, COMFORTSTAR T1W18P, COMFORTSTAR TPA-18C.
What refrigerant does the ComfortStar CZP18CD(O) use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $485/yrYou save $476/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump ComfortStar CZP18CD(O)
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$485
Current system, per year
$961
You save per year
$476
Payback
14.7 years
Net after 10 years
-$2,240

Cooling $275Heating $209Electricity used: 3,030 kWhSaved vs. a minimum-efficiency heat pump: $257

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 18,000 BTU models

See all 465 18,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 12, 2026. How we use the data.