18,000 BTU mini-split heat pump · 4DH SERIES
Concord 4DHP2S18M-1P
Average cooling and heating efficiency for a 18,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #162 of 465 18,000 BTU mini-splits for cooling efficiency, and costs about $454 a year to run in a mixed climate like Atlanta.
- SEER2
- 22.9 Cooling efficiency over a seasonAverage · beats 58%
- HSPF2
- 10.5 Heating efficiency over a seasonAverage · beats 61%
- EER2
- 13.9 Cooling efficiency on a 95°F dayVery good · beats 79%
- Heat at 5°F
- 13,300 BTU/h66% of its 47°F outputAverage · beats 48%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 13,300 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
- You want a choice of indoor units - 18 certified pairings.
Think twice if…
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | Concord |
| Also sold as | ALLIED, Ducane, Armstrong Air, AIREASE |
| Outdoor unit model | 4DHP2S18M-1P |
| Series | 4DH SERIES |
| Type | Mini-split heat pump |
| Nominal size | 18,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | January 1, 2022 |
| Last certified | June 29, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 22.9 (range 19.0-22.9) |
| EER2Efficiency at 95°F outdoors | 12.0-13.9 |
| Cooling capacity | 18,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.8-10.5 |
| Capacity at 47°F | 19,000 BTU/h |
| Capacity at 17°F | 14,300-14,800 BTU/h |
| Capacity at 5°F | 12,600-13,300 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.00 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| - DUCANE | 22.9 | 13.9 | 10.5 | 12,600 | 208106842 |
| - Armstrong Air | 22.9 | 13.9 | 10.5 | 12,600 | 208106812 |
| - CONCORD | 22.9 | 13.9 | 10.5 | 12,600 | 208106827 |
| - CONCORD | 22.9 | 13.9 | 10.5 | 12,600 | 208106827 |
| - AirEase | 22.9 | 13.9 | 10.5 | 12,600 | 208106797 |
| - Allied | 22.9 | 13.9 | 10.5 | 12,600 | 208106782 |
| - Allied | 22.9 | 13.9 | 10.5 | 12,600 | 208106782 |
| - Allied | 21.0 | 13.0 | 10.2 | 12,900 | 208106784 |
| - CONCORD | 21.0 | 13.0 | 10.2 | 12,900 | 208106829 |
| - DUCANE | 21.0 | 13.0 | 10.2 | 12,900 | 208106844 |
| - AirEase | 21.0 | 13.0 | 10.2 | 12,900 | 208106799 |
| - Armstrong Air | 21.0 | 13.0 | 10.2 | 12,900 | 208106814 |
| - Armstrong Air · cold climate | 19.0 | 12.0 | 9.8 | 13,300 | 208106813 |
| - DUCANE · cold climate | 19.0 | 12.0 | 9.8 | 13,300 | 208106843 |
| - AirEase · cold climate | 19.0 | 12.0 | 9.8 | 13,300 | 208106798 |
| - Allied · cold climate | 19.0 | 12.0 | 9.8 | 13,300 | 208106783 |
| - CONCORD · cold climate | 19.0 | 12.0 | 9.8 | 13,300 | 208106828 |
| - CONCORD · cold climate | 19.0 | 12.0 | 9.8 | 13,300 | 208106828 |
Yearly running cost in 10 large cities
- Phoenix, AZ$474/yr
- Miami, FL$371/yr
- Houston, TX$426/yr
- Atlanta, GA$454/yr
- Los Angeles, CA$447/yr
- New York, NY$1,113/yr
- Chicago, IL$909/yr
- Denver, CO$760/yr
- Seattle, WA$471/yr
- Minneapolis, MN$943/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Concord 4DHP2S18M-1P?
- The Concord 4DHP2S18M-1P is rated at up to 22.9 SEER2 and 13.9 EER2 for cooling and up to 10.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 18 certified matchups SEER2 ranges from 19.0-22.9.
- Is the Concord 4DHP2S18M-1P good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 13,300 BTU/h at 5°F with a COP of 2.00, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
- How much does the Concord 4DHP2S18M-1P cost to run per year?
- At its rated efficiency it costs about $371-$1,113 a year in electricity in large U.S. cities, depending on climate and local rates - for example $474 in Phoenix and $943 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- What refrigerant does the Concord 4DHP2S18M-1P use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 18,000 BTU models
- Bosch BMS500-AAM018-1CSXRC · cold climate22.9 SEER2 · 10.5 HSPF2
- Cooper&Hunter CH-18MES-230VO · cold climate22.9 SEER2 · 10.5 HSPF2
- Mitsubishi Electric SUZ-KA18NA222.9 SEER2 · 10.7 HSPF2
- DIRECT AIR DIRM-18DA25-2Z · cold climate22.9 SEER2 · 10.5 HSPF2
- Trane / Mitsubishi Electric NTXSKS18A11222.9 SEER2 · 11.2 HSPF2
- DIYCOOL ES-18Z-M2B · cold climate22.9 SEER2 · 10.5 HSPF2
- ECO AC EHH-O18KBA · cold climate23.0 SEER2 · 8.5 HSPF2
- Lennox MPC018S4M-1P · cold climate22.9 SEER2 · 10.5 HSPF2
See all 465 18,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 29, 2026. How we use the data.