HVAC Rated

36,000 BTU mini-split heat pump · CDH Series

Continental NDHAMB-36-O

Below average cooling efficiency and average heating efficiency for a 36,000 BTU mini-split heat pump, and certified for cold climates.

Ranks #107 of 205 36,000 BTU mini-splits for cooling efficiency, and costs about $898 a year to run in a mixed climate like Atlanta.

SEER2
21.2 Cooling efficiency over a season
Below average · beats 35%
HSPF2
10.6 Heating efficiency over a season
Average · beats 64%
EER2
12.5 Cooling efficiency on a 95°F day
Average · beats 44%
Heat at 5°F
38,000 BTU/h103% of its 47°F output
Average · beats 48%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 38,000 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Cooling cost matters most - its SEER2 is below average for mini-splits.

Calculate my running cost

Details

Specifications36,000 BTU, R-454B
General
BrandContinental
Outdoor unit modelNDHAMB-36-O
SeriesCDH Series
TypeMini-split heat pump
Nominal size36,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceMay 15, 2024
Last certifiedMay 6, 2026
Cooling
SEER2Seasonal efficiency, higher is better21.2 (range 19.4-21.2)
EER2Efficiency at 95°F outdoors12.0-12.5
Cooling capacity36,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better10.4-10.6
Capacity at 47°F36,000 BTU/h
Capacity at 17°F38,000 BTU/h
Capacity at 5°F37,000-38,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00
ENERGY STAR cold climateYes
Heating output as it gets colder103% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:

Certified matchups2 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
- CONTINENTAL · cold climate21.212.510.637,000215213730
- CONTINENTAL · cold climate19.412.010.438,000215213729
Yearly running cost in 10 large cities$798-$2,151

At each state's average electricity price and the city's typical heating and cooling hours.

Questions4
What is the SEER2 rating of the Continental NDHAMB-36-O?
The Continental NDHAMB-36-O is rated at up to 21.2 SEER2 and 12.5 EER2 for cooling and up to 10.6 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 2 certified matchups SEER2 ranges from 19.4-21.2.
Is the Continental NDHAMB-36-O good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 38,000 BTU/h at 5°F with a COP of 2.00, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the Continental NDHAMB-36-O cost to run per year?
At its rated efficiency it costs about $798-$2,151 a year in electricity in large U.S. cities, depending on climate and local rates - for example $986 in Phoenix and $1,799 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
What refrigerant does the Continental NDHAMB-36-O use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $980/yrYou save $876/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Continental NDHAMB-36-O
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$980
Current system, per year
$1,856
You save per year
$876
Payback
15.4 years
Net after 10 years
-$4,737

Cooling $598Heating $382Electricity used: 6,124 kWhSaved vs. a minimum-efficiency heat pump: $444

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 36,000 BTU models

See all 205 36,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 6, 2026. How we use the data.