60,000 BTU mini-split heat pump · CH series

Cooper&Hunter CH-NHPR60LCU-230VO

Below average cooling efficiency and average heating efficiency for a 60,000 BTU mini-split heat pump, and certified for cold climates.

Ranks #39 of 44 60,000 BTU mini-splits for cooling efficiency, and costs about $1,598 a year to run in a mixed climate like Atlanta.

SEER2
17.3 Cooling efficiency over a season
Below average · beats 2%
HSPF2
10.2 Heating efficiency over a season
Average · beats 53%
EER2
9.0 Cooling efficiency on a 95°F day
Below average · beats 1%
Heat at 5°F
56,500 BTU/h94% of its 47°F output
Below average · beats 36%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 56,500 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Cooling cost matters most - its SEER2 is below average for mini-splits.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications60,000 BTU, R-410A
General
BrandCooper&Hunter
Outdoor unit modelCH-NHPR60LCU-230VO
SeriesCH series
TypeMini-split heat pump
Nominal size60,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceJanuary 1, 2022
Last certifiedApril 22, 2026
Cooling
SEER2Seasonal efficiency, higher is better17.3 (range 15.5-17.3)
EER2Efficiency at 95°F outdoors9.0-9.4
Cooling capacity55,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better9.2-10.2
Capacity at 47°F57,000-60,000 BTU/h
Capacity at 17°F40,000-41,000 BTU/h
Capacity at 5°F53,000-56,500 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.96-1.97
ENERGY STAR cold climateYes
Heating output as it gets colder94% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CH-60LCFC/I at the standard test temperatures, in BTU/h:

Certified matchups6 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
CH-60LCFC/I · cold climate17.39.010.256,500211246027
CH-60LCFC-W · cold climate17.39.010.256,500213265595
CH-60LCDTU/I · cold climate15.89.49.553,000211246028
CH-60LCDT-W · cold climate15.89.49.553,000213265585
CH-60AHU · cold climate15.59.09.253,500211246029
CH-60AHU-W · cold climate15.59.09.253,500213265612
Yearly running cost in 10 large cities$1,491-$3,769

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Cooper&Hunter CH-NHPR60LCU-230VO?
The Cooper&Hunter CH-NHPR60LCU-230VO is rated at up to 17.3 SEER2 and 9.0 EER2 for cooling and up to 10.2 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 6 certified matchups SEER2 ranges from 15.5-17.3.
Is the Cooper&Hunter CH-NHPR60LCU-230VO good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 56,500 BTU/h at 5°F with a COP of 1.97, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the Cooper&Hunter CH-NHPR60LCU-230VO cost to run per year?
At its rated efficiency it costs about $1,491-$3,769 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,808 in Phoenix and $3,126 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Cooper&Hunter CH-NHPR60LCU-230VO?
ENERGY STAR lists 6 certified combinations for this outdoor unit. The highest-rated ones use CH-60LCFC/I, CH-60LCFC-W, CH-60LCDTU/I.
What refrigerant does the Cooper&Hunter CH-NHPR60LCU-230VO use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,778/yrYou save $1,140/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Cooper&Hunter CH-NHPR60LCU-230VO
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,778
Current system, per year
$2,918
You save per year
$1,140
Payback
18.0 years
Net after 10 years
-$9,101

Cooling $1,119Heating $659Electricity used: 11,112 kWhSaved vs. a minimum-efficiency heat pump: $472

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.