18,000 BTU mini-split heat pump · CH Series
Cooper&Hunter CH-RES18-230VO
Very good cooling efficiency and excellent heating efficiency for a 18,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #63 of 465 18,000 BTU mini-splits for cooling efficiency, and costs about $368 a year to run in a mixed climate like Atlanta.
- SEER2
- 24.0 Cooling efficiency over a seasonVery good · beats 75%
- HSPF2
- 13.5 Heating efficiency over a seasonExcellent · beats 96%
- EER2
- 13.5 Cooling efficiency on a 95°F dayVery good · beats 74%
- Heat at 5°F
- 14,000 BTU/h72% of its 47°F outputExcellent · beats 90%
A good fit if…
- You want low cooling bills - its SEER2 beats 75% of mini-splits.
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 14,000 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 96% of mini-splits.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | Cooper&Hunter |
| Outdoor unit model | CH-RES18-230VO |
| Series | CH Series |
| Type | Mini-split heat pump |
| Nominal size | 18,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | October 10, 2024 |
| Last certified | May 6, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 24.0 (range 18.5-24.0) |
| EER2Efficiency at 95°F outdoors | 12.1-13.5 |
| Cooling capacity | 16,000-18,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.8-13.5 |
| Capacity at 47°F | 17,000-20,000 BTU/h |
| Capacity at 17°F | 13,200-15,000 BTU/h |
| Capacity at 5°F | 12,800-14,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.05-2.35 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CH-R18MOLVWM-230VI at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| CH-R18MOLVWM-230VI · cold climate | 24.0 | 13.5 | 11.1 | 13,000 | 215864149 |
| CH-RB18MOLVWM-230VI · cold climate | 24.0 | 13.5 | 11.1 | 13,000 | 215864161 |
| CH-RSH16MMC · cold climate | 23.8 | 12.5 | 13.5 | 13,100 | 215864237 |
| CH-PRO18MASTWM-230VI · cold climate | 23.5 | 12.7 | 10.8 | 12,800 | 215864170 |
| CH-RH18MASTWM-230VI · cold climate | 23.5 | 12.7 | 10.8 | 12,800 | 215864186 |
| CH-RSH18MFC · cold climate | 22.3 | 12.5 | 10.4 | 12,800 | 215864238 |
| CH-RSH18MCT1W · cold climate | 22.2 | 12.5 | 12.2 | 13,100 | 215864250 |
| CH-RSH18MCT · cold climate | 20.7 | 12.5 | 11.4 | 12,800 | 215864196 |
| CH-RH18MCT · cold climate | 20.7 | 12.5 | 11.4 | 12,800 | 215864208 |
| CH-RS18MDT-MS · cold climate | 20.0 | 12.5 | 10.5 | 14,000 | 215864227 |
| CH-RS18MAHU · cold climate | 18.5 | 12.1 | 9.8 | 13,000 | 215864131 |
Yearly running cost in 10 large cities
- Phoenix, AZ$422/yr
- Miami, FL$351/yr
- Houston, TX$378/yr
- Atlanta, GA$368/yr
- Los Angeles, CA$355/yr
- New York, NY$861/yr
- Chicago, IL$696/yr
- Denver, CO$576/yr
- Seattle, WA$352/yr
- Minneapolis, MN$711/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Cooper&Hunter CH-RES18-230VO?
- The Cooper&Hunter CH-RES18-230VO is rated at up to 24.0 SEER2 and 13.5 EER2 for cooling and up to 13.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 11 certified matchups SEER2 ranges from 18.5-24.0.
- Is the Cooper&Hunter CH-RES18-230VO good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 14,000 BTU/h at 5°F with a COP of 2.35, so it is still 2.4 times as efficient as electric resistance heat at that temperature.
- How much does the Cooper&Hunter CH-RES18-230VO cost to run per year?
- At its rated efficiency it costs about $351-$861 a year in electricity in large U.S. cities, depending on climate and local rates - for example $422 in Phoenix and $711 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Cooper&Hunter CH-RES18-230VO?
- ENERGY STAR lists 11 certified combinations for this outdoor unit. The highest-rated ones use CH-R18MOLVWM-230VI, CH-RB18MOLVWM-230VI, CH-RSH16MMC.
- What refrigerant does the Cooper&Hunter CH-RES18-230VO use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 18,000 BTU models
- CanAir 4C25SCH18H21 · cold climate24.0 SEER2 · 13.5 HSPF2
- Mainline ML18HP230NEX-O · cold climate24.0 SEER2 · 13.5 HSPF2
- AI AIR CONDITIONING AO24-18N2-M1 · cold climate24.0 SEER2 · 13.5 HSPF2
- MDV MOX430-18HFN10-M1 · cold climate24.0 SEER2 · 13.5 HSPF2
- TOSOT TWH18PR32DO · cold climate24.5 SEER2 · 9.0 HSPF2
- Napoleon NDHAS22BA-18-O · cold climate24.0 SEER2 · 13.5 HSPF2
- TOSOT TWH18AUC25R32A1DO · cold climate24.5 SEER2 · 9.0 HSPF2
- NOVAIR LEA18SZ26-O · cold climate24.0 SEER2 · 13.5 HSPF2
See all 465 18,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 6, 2026. How we use the data.