6,000 BTU mini-split heat pump · CH Series
Cooper&Hunter CH-RHP06F9-230VO
Very good cooling efficiency and excellent heating efficiency for a 6,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #25 of 42 6,000 BTU mini-splits for cooling efficiency, and costs about $125 a year to run in a mixed climate like Atlanta.
- SEER2
- 25.5 Cooling efficiency over a seasonVery good · beats 88%
- HSPF2
- 14.8 Heating efficiency over a seasonExcellent · beats 99%
- EER2
- 18.0 Cooling efficiency on a 95°F dayExcellent · beats 99%
- Heat at 5°F
- 8,100 BTU/h110% of its 47°F outputExcellent · beats 93%
A good fit if…
- You want low cooling bills - its SEER2 beats 88% of mini-splits.
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 8,100 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 99% of mini-splits.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | Cooper&Hunter |
| Outdoor unit model | CH-RHP06F9-230VO |
| Series | CH Series |
| Type | Mini-split heat pump |
| Nominal size | 6,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | October 12, 2024 |
| Last certified | May 6, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 25.5 (range 21.4-25.5) |
| EER2Efficiency at 95°F outdoors | 14.4-18.0 |
| Cooling capacity | 6,000-6,500 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 12.0-14.8 |
| Capacity at 47°F | 7,000-8,000 BTU/h |
| Capacity at 17°F | 7,000-8,700 BTU/h |
| Capacity at 5°F | 7,500-8,100 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.30-2.40 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CH-PRO06MASTWM-230VI at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| CH-PRO06MASTWM-230VI · cold climate | 25.5 | 18.0 | 14.8 | 7,700 | 215864172 |
| CH-RH06MASTWM-230VI · cold climate | 25.5 | 18.0 | 14.8 | 7,700 | 215864178 |
| CH-R06MOLVWM-230VI · cold climate | 25.3 | 16.0 | 14.6 | 7,500 | 215864151 |
| CH-RB06MOLVWM-230VI · cold climate | 25.3 | 16.0 | 14.6 | 7,500 | 215864163 |
| CH-RSH06-12MCT1W · cold climate | 22.0 | 15.0 | 12.0 | 8,100 | 215864251 |
| CH-RS06MDT-MS · cold climate | 21.4 | 14.4 | 13.8 | 7,800 | 215864212 |
| CH-RS06-12MDT- MS · cold climate | 21.4 | 14.4 | 13.8 | 7,800 | 215864215 |
Yearly running cost in 10 large cities
- Phoenix, AZ$137/yr
- Miami, FL$111/yr
- Houston, TX$123/yr
- Atlanta, GA$125/yr
- Los Angeles, CA$121/yr
- New York, NY$298/yr
- Chicago, IL$242/yr
- Denver, CO$201/yr
- Seattle, WA$124/yr
- Minneapolis, MN$249/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Cooper&Hunter CH-RHP06F9-230VO?
- The Cooper&Hunter CH-RHP06F9-230VO is rated at up to 25.5 SEER2 and 18.0 EER2 for cooling and up to 14.8 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 7 certified matchups SEER2 ranges from 21.4-25.5.
- Is the Cooper&Hunter CH-RHP06F9-230VO good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 8,100 BTU/h at 5°F with a COP of 2.40, so it is still 2.4 times as efficient as electric resistance heat at that temperature.
- How much does the Cooper&Hunter CH-RHP06F9-230VO cost to run per year?
- At its rated efficiency it costs about $111-$298 a year in electricity in large U.S. cities, depending on climate and local rates - for example $137 in Phoenix and $249 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Cooper&Hunter CH-RHP06F9-230VO?
- ENERGY STAR lists 7 certified combinations for this outdoor unit. The highest-rated ones use CH-PRO06MASTWM-230VI, CH-RH06MASTWM-230VI, CH-R06MOLVWM-230VI.
- What refrigerant does the Cooper&Hunter CH-RHP06F9-230VO use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 6,000 BTU models
- Comfort-Aire A-VHP06SA-1 · cold climate25.5 SEER2 · 14.8 HSPF2
- Innovair MOS06H2BH0A · cold climate25.5 SEER2 · 14.8 HSPF2
- Blueridge BXS5A06UC0 · cold climate25.5 SEER2 · 14.8 HSPF2
- KERR A-KHP06SA-1 · cold climate25.5 SEER2 · 14.8 HSPF2
- MDV MOX230-06HFN10-M1 · cold climate25.7 SEER2 · 12.8 HSPF2
- Midea MO1HS-H06B-2A · cold climate25.5 SEER2 · 14.8 HSPF2
- MDV MOX230-06HFN10-M1X · cold climate25.7 SEER2 · 14.8 HSPF2
- NOVAIR LEA06SZ36-O · cold climate25.5 SEER2 · 14.8 HSPF2
See all 42 6,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 6, 2026. How we use the data.