5-ton packaged heat pump · DHH
Daikin DHH0601********A
Very good cooling efficiency and average heating efficiency for a 5-ton packaged heat pump, but not rated for cold climates.
Ranks #12 of 29 5 ton packaged heat pumps for cooling efficiency, and costs about $1,987 a year to run in a mixed climate like Atlanta.
- SEER2
- 16.4 Cooling efficiency over a seasonVery good · beats 72%
- HSPF2
- 7.7 Heating efficiency over a seasonAverage · beats 56%
- EER2
- 12.2 Cooling efficiency on a 95°F dayExcellent · beats 96%
- Heat at 5°F
- 27,000 BTU/h46% of its 47°F outputVery good · beats 73%
A good fit if…
- You want low cooling bills - its SEER2 beats 72% of packaged heat pumps.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
Details
Specifications
| General | |
|---|---|
| Brand | Daikin |
| Outdoor unit model | DHH0601********A |
| Series | DHH |
| Type | Packaged heat pump |
| Nominal size | 5 ton |
| CompressorVariable-speed units run longer at low power | Two-stage |
| Refrigerant | R-32 |
| Connected (smart) capable | No |
| On the market since | November 25, 2024 |
| Last certified | February 11, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 16.4 (range 16.4) |
| EER2Efficiency at 95°F outdoors | 12.2 |
| Cooling capacity | 60,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.7 |
| Capacity at 47°F | 59,000 BTU/h |
| Capacity at 17°F | 35,000 BTU/h |
| Capacity at 5°F | 27,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.00 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| - | 16.4 | 12.2 | 7.7 | 27,000 | 216018413 |
Yearly running cost in 10 large cities
- Phoenix, AZ$2,149/yr
- Miami, FL$1,722/yr
- Houston, TX$1,927/yr
- Atlanta, GA$1,987/yr
- Los Angeles, CA$1,942/yr
- New York, NY$4,793/yr
- Chicago, IL$3,900/yr
- Denver, CO$3,250/yr
- Seattle, WA$2,002/yr
- Minneapolis, MN$4,025/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Daikin DHH0601********A?
- The Daikin DHH0601********A is rated at up to 16.4 SEER2 and 12.2 EER2 for cooling and up to 7.7 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
- Is the Daikin DHH0601********A good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 5-ton model.
- How much does the Daikin DHH0601********A cost to run per year?
- At its rated efficiency it costs about $1,722-$4,793 a year in electricity in large U.S. cities, depending on climate and local rates - for example $2,149 in Phoenix and $4,025 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- What refrigerant does the Daikin DHH0601********A use?
- It uses R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 5 ton models
- Hisense AR-60U3R25U · cold climate17.0 SEER2 · 8.1 HSPF2
- Bosch BPHA-60RCB-M16S · cold climate16.0 SEER2 · 8.5 HSPF2
- MRCOOL MDPH180604 · cold climate17.0 SEER2 · 8.3 HSPF2
- York PL5E60N00D21 · cold climate16.0 SEER2 · 8.5 HSPF2
- 1HVAC ACIQ-PHH1760000K000V · cold climate17.0 SEER2 · 8.3 HSPF2
- Carrier 50NR-B60---3015.5 SEER2 · 7.7 HSPF2
- Innovair TPV60H2XA · cold climate17.0 SEER2 · 8.8 HSPF2
- Heil PHB560000K000B15.5 SEER2 · 7.7 HSPF2
See all 29 5 ton packaged heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of February 11, 2026. How we use the data.