HVAC Rated

24,000 BTU mini-split heat pump · OTERRA

Daikin RXF24AXVJU

Below average cooling and heating efficiency for a 24,000 BTU mini-split heat pump, but not rated for cold climates.

Ranks #297 of 430 24,000 BTU mini-splits for cooling efficiency, and costs about $639 a year to run in a mixed climate like Atlanta.

SEER2
21.0 Cooling efficiency over a season
Below average · beats 30%
HSPF2
9.1 Heating efficiency over a season
Below average · beats 13%
EER2
12.0 Cooling efficiency on a 95°F day
Below average · beats 25%
Heat at 5°F
10,800 BTU/h46% of its 47°F output
Below average · beats 27%

A good fit if…

  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for mini-splits.
  • You mainly need heat - its HSPF2 is below average for mini-splits.

Calculate my running cost

Details

Specifications24,000 BTU, R-32
General
BrandDaikin
Outdoor unit modelRXF24AXVJU
SeriesOTERRA
TypeMini-split heat pump
Nominal size24,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-32
Connected (smart) capableNo
On the market sinceJanuary 29, 2024
Last certifiedNovember 20, 2025
Cooling
SEER2Seasonal efficiency, higher is better21.0 (range 21.0)
EER2Efficiency at 95°F outdoors12.0
Cooling capacity22,400 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better9.1
Capacity at 47°F23,600 BTU/h
Capacity at 17°F14,600 BTU/h
Capacity at 5°F10,800 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.90
ENERGY STAR cold climateNo
Heating output as it gets colder46% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FTXF24AXVJU at the standard test temperatures, in BTU/h:

Certified matchups1 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
FTXF24AXVJU DAIKIN21.012.09.110,800213895722
Yearly running cost in 10 large cities$505-$1,581

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Daikin RXF24AXVJU?
The Daikin RXF24AXVJU is rated at up to 21.0 SEER2 and 12.0 EER2 for cooling and up to 9.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
Is the Daikin RXF24AXVJU good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 24,000 BTU model.
How much does the Daikin RXF24AXVJU cost to run per year?
At its rated efficiency it costs about $505-$1,581 a year in electricity in large U.S. cities, depending on climate and local rates - for example $654 in Phoenix and $1,346 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Daikin RXF24AXVJU?
ENERGY STAR lists 1 certified combination for this outdoor unit. The highest-rated one uses DAIKIN FTXF24AXVJU.
What refrigerant does the Daikin RXF24AXVJU use?
It uses R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $666/yrYou save $509/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Daikin RXF24AXVJU
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$666
Current system, per year
$1,175
You save per year
$509
Payback
16.7 years
Net after 10 years
-$3,413

Cooling $375Heating $290Electricity used: 4,162 kWhSaved vs. a minimum-efficiency heat pump: $238

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 24,000 BTU models

See all 430 24,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of November 20, 2025. How we use the data.