18,000 BTU mini-split heat pump · DIR Series
DIRECT AIR DIRM4-18DA25-1Z
Very good cooling and heating efficiency for a 18,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #111 of 465 18,000 BTU mini-splits for cooling efficiency, and costs about $412 a year to run in a mixed climate like Atlanta.
- SEER2
- 23.5 Cooling efficiency over a seasonVery good · beats 70%
- HSPF2
- 11.4 Heating efficiency over a seasonVery good · beats 82%
- EER2
- 12.7 Cooling efficiency on a 95°F dayAverage · beats 54%
- Heat at 5°F
- 14,200 BTU/h71% of its 47°F outputExcellent · beats 93%
A good fit if…
- You want low cooling bills - its SEER2 beats 70% of mini-splits.
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 14,200 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 82% of mini-splits.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | DIRECT AIR |
| Outdoor unit model | DIRM4-18DA25-1Z |
| Series | DIR Series |
| Type | Mini-split heat pump |
| Nominal size | 18,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | December 1, 2024 |
| Last certified | May 6, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 23.5 (range 20.0-23.5) |
| EER2Efficiency at 95°F outdoors | 12.5-13.3 |
| Cooling capacity | 16,800-18,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 10.4-11.4 |
| Capacity at 47°F | 18,000-20,000 BTU/h |
| Capacity at 17°F | 13,700-15,000 BTU/h |
| Capacity at 5°F | 12,800-14,200 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.05-2.40 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with DIRM4-18HP-WM at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| DIRM4-18HP-WM · cold climate | 23.5 | 12.7 | 10.8 | 12,800 | 216571369 |
| DIRM4-18HP-CF · cold climate | 22.3 | 12.5 | 10.4 | 12,800 | 216571378 |
| DIRM4-18HP-CA · cold climate | 20.7 | 12.5 | 11.4 | 12,800 | 216788523 |
| DIRM4-18HP-DU · cold climate | 20.0 | 13.3 | 11.3 | 14,200 | 217447835 |
Yearly running cost in 10 large cities
- Phoenix, AZ$448/yr
- Miami, FL$360/yr
- Houston, TX$402/yr
- Atlanta, GA$412/yr
- Los Angeles, CA$402/yr
- New York, NY$991/yr
- Chicago, IL$806/yr
- Denver, CO$671/yr
- Seattle, WA$413/yr
- Minneapolis, MN$831/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the DIRECT AIR DIRM4-18DA25-1Z?
- The DIRECT AIR DIRM4-18DA25-1Z is rated at up to 23.5 SEER2 and 12.7 EER2 for cooling and up to 11.4 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 4 certified matchups SEER2 ranges from 20.0-23.5.
- Is the DIRECT AIR DIRM4-18DA25-1Z good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 14,200 BTU/h at 5°F with a COP of 2.40, so it is still 2.4 times as efficient as electric resistance heat at that temperature.
- How much does the DIRECT AIR DIRM4-18DA25-1Z cost to run per year?
- At its rated efficiency it costs about $360-$991 a year in electricity in large U.S. cities, depending on climate and local rates - for example $448 in Phoenix and $831 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the DIRECT AIR DIRM4-18DA25-1Z?
- ENERGY STAR lists 4 certified combinations for this outdoor unit. The highest-rated ones use DIRM4-18HP-WM, DIRM4-18HP-CF, DIRM4-18HP-CA.
- What refrigerant does the DIRECT AIR DIRM4-18DA25-1Z use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 18,000 BTU models
- MOOVAIR MSHEA18C2AN1 · cold climate23.5 SEER2 · 12.2 HSPF2
- Midea MOX430-18HFN10-M1P · cold climate23.5 SEER2 · 11.4 HSPF2
- ECO-AIR EDSO-18E · cold climate23.5 SEER2 · 12.2 HSPF2
- Fujitsu AOUH18LUAS1 · cold climate23.5 SEER2 · 11.2 HSPF2
- Bosch BMS500-AAS018-1CSXRD · cold climate23.5 SEER2 · 12.2 HSPF2
- AC Pro AOX430-18HFN1-MT8W23.5 SEER2 · 10.8 HSPF2
- Star Air Kontrol SAK-18-24MS/220 · cold climate23.7 SEER2 · 10.3 HSPF2
- Bosch BMS500-AAS018-1CSXRC23.5 SEER2 · 10.8 HSPF2
See all 465 18,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 6, 2026. How we use the data.