9,000 BTU mini-split heat pump · ACIQ
DIYCOOL ACIQ-09Z-HP115B
Below average cooling and heating efficiency for a 9,000 BTU mini-split heat pump, but not rated for cold climates.
Ranks #307 of 395 9,000 BTU mini-splits for cooling efficiency, and costs about $266 a year to run in a mixed climate like Atlanta.
- SEER2
- 21.5 Cooling efficiency over a seasonBelow average · beats 39%
- HSPF2
- 9.0 Heating efficiency over a seasonBelow average · beats 10%
- EER2
- 12.5 Cooling efficiency on a 95°F dayAverage · beats 44%
- Heat at 5°F
- 6,000 BTU/h60% of its 47°F outputBelow average · beats 22%
A good fit if…
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- Cooling cost matters most - its SEER2 is below average for mini-splits.
- You mainly need heat - its HSPF2 is below average for mini-splits.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | DIYCOOL |
| Also sold as | ACIQ, 1HVAC, PolarWave, STEALTH |
| Outdoor unit model | ACIQ-09Z-HP115B |
| Series | ACIQ |
| Type | Mini-split heat pump |
| Nominal size | 9,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | October 1, 2022 |
| Last certified | May 12, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 21.5 (range 21.5) |
| EER2Efficiency at 95°F outdoors | 12.5 |
| Cooling capacity | 9,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.0 |
| Capacity at 47°F | 10,000 BTU/h |
| Capacity at 17°F | 6,800 BTU/h |
| Capacity at 5°F | 6,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.89 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with ACIQ-09W-HP115B at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| ACIQ-09W-HP115B ACIQ | 21.5 | 12.5 | 9.0 | 6,000 | 207825526 |
| ACIQ-09W-HP115B 1HVAC | 21.5 | 12.5 | 9.0 | 6,000 | 207825507 |
| ACIQ-09W-HP115B | 21.5 | 12.5 | 9.0 | 6,000 | 207825545 |
| ACIQ-09W-HP115B PolarWave | 21.5 | 12.5 | 9.0 | 6,000 | 212316066 |
| ACIQ-09W-HP115B STEALTH | 21.5 | 12.5 | 9.0 | 6,000 | 212316152 |
| ACIQ-09W-HP115B | 21.5 | 12.5 | 9.0 | 6,000 | 207825545 |
Yearly running cost in 10 large cities
- Phoenix, AZ$264/yr
- Miami, FL$199/yr
- Houston, TX$237/yr
- Atlanta, GA$266/yr
- Los Angeles, CA$265/yr
- New York, NY$668/yr
- Chicago, IL$549/yr
- Denver, CO$461/yr
- Seattle, WA$287/yr
- Minneapolis, MN$573/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the DIYCOOL ACIQ-09Z-HP115B?
- The DIYCOOL ACIQ-09Z-HP115B is rated at up to 21.5 SEER2 and 12.5 EER2 for cooling and up to 9.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
- Is the DIYCOOL ACIQ-09Z-HP115B good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 9,000 BTU model.
- How much does the DIYCOOL ACIQ-09Z-HP115B cost to run per year?
- At its rated efficiency it costs about $199-$668 a year in electricity in large U.S. cities, depending on climate and local rates - for example $264 in Phoenix and $573 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the DIYCOOL ACIQ-09Z-HP115B?
- ENERGY STAR lists 6 certified combinations for this outdoor unit. The highest-rated ones use ACIQ ACIQ-09W-HP115B, 1HVAC ACIQ-09W-HP115B, ACIQ-09W-HP115B.
- What refrigerant does the DIYCOOL ACIQ-09Z-HP115B use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 9,000 BTU models
- CanAir 4C22SCH09H11 · cold climate21.5 SEER2 · 9.0 HSPF2
- Mainline ML09HP115GEN-O · cold climate21.5 SEER2 · 9.0 HSPF2
- AproDr AAG22-09H1B · cold climate21.5 SEER2 · 9.0 HSPF2
- Midea MO1BS-H09B-1A · cold climate21.5 SEER2 · 9.0 HSPF2
- AC Pro AOX230-09HFN1-BS5W21.5 SEER2 · 9.0 HSPF2
- MRCOOL A-09-HP-C-115C21.5 SEER2 · 9.0 HSPF2
- 1HVAC ACIQ-09Z-HP115C21.5 SEER2 · 9.0 HSPF2
- MRCOOL A-09-HP-C-115D-O21.5 SEER2 · 9.0 HSPF2
See all 395 9,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 12, 2026. How we use the data.