60,000 BTU mini-split heat pump · ACIQ
DIYCOOL ACIQ-55Z-HH-M5B
Average cooling efficiency and below average heating efficiency for a 60,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #13 of 44 60,000 BTU mini-splits for cooling efficiency, and costs about $1,449 a year to run in a mixed climate like Atlanta.
- SEER2
- 22.0 Cooling efficiency over a seasonAverage · beats 48%
- HSPF2
- 9.5 Heating efficiency over a seasonBelow average · beats 24%
- EER2
- 10.5 Cooling efficiency on a 95°F dayBelow average · beats 6%
- Heat at 5°F
- 46,000 BTU/h84% of its 47°F outputBelow average · beats 27%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 46,000 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
- You want a choice of indoor units - 15 certified pairings.
Think twice if…
- You mainly need heat - its HSPF2 is below average for mini-splits.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | DIYCOOL |
| Also sold as | ACIQ, 1HVAC, PolarWave, STEALTH |
| Outdoor unit model | ACIQ-55Z-HH-M5B |
| Series | ACIQ |
| Type | Mini-split heat pump |
| Nominal size | 60,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | October 1, 2022 |
| Last certified | June 25, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 22.0 (range 18.8-22.0) |
| EER2Efficiency at 95°F outdoors | 10.5 |
| Cooling capacity | 55,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.3-9.5 |
| Capacity at 47°F | 55,000 BTU/h |
| Capacity at 17°F | 34,400-35,200 BTU/h |
| Capacity at 5°F | 46,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.90 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| - ACIQ · cold climate | 22.0 | 10.5 | 9.5 | 46,000 | 210857380 |
| - · cold climate | 22.0 | 10.5 | 9.5 | 46,000 | 210857398 |
| - 1HVAC · cold climate | 22.0 | 10.5 | 9.5 | 46,000 | 210857362 |
| - PolarWave · cold climate | 22.0 | 10.5 | 9.5 | 46,000 | 212316117 |
| - STEALTH · cold climate | 22.0 | 10.5 | 9.5 | 46,000 | 212316203 |
| - PolarWave · cold climate | 20.4 | 10.5 | 9.4 | 46,000 | 212316119 |
| - STEALTH · cold climate | 20.4 | 10.5 | 9.4 | 46,000 | 212316205 |
| - ACIQ · cold climate | 20.4 | 10.5 | 9.4 | 46,000 | 210857382 |
| - · cold climate | 20.4 | 10.5 | 9.4 | 46,000 | 210857400 |
| - 1HVAC · cold climate | 20.4 | 10.5 | 9.4 | 46,000 | 210857364 |
| - · cold climate | 18.8 | 10.5 | 9.3 | 46,000 | 210857399 |
| - 1HVAC · cold climate | 18.8 | 10.5 | 9.3 | 46,000 | 210857363 |
| - ACIQ · cold climate | 18.8 | 10.5 | 9.3 | 46,000 | 210857381 |
| - PolarWave · cold climate | 18.8 | 10.5 | 9.3 | 46,000 | 212316118 |
| - STEALTH · cold climate | 18.8 | 10.5 | 9.3 | 46,000 | 212316204 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,511/yr
- Miami, FL$1,181/yr
- Houston, TX$1,357/yr
- Atlanta, GA$1,449/yr
- Los Angeles, CA$1,428/yr
- New York, NY$3,558/yr
- Chicago, IL$2,907/yr
- Denver, CO$2,431/yr
- Seattle, WA$1,505/yr
- Minneapolis, MN$3,015/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the DIYCOOL ACIQ-55Z-HH-M5B?
- The DIYCOOL ACIQ-55Z-HH-M5B is rated at up to 22.0 SEER2 and 10.5 EER2 for cooling and up to 9.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 15 certified matchups SEER2 ranges from 18.8-22.0.
- Is the DIYCOOL ACIQ-55Z-HH-M5B good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 46,000 BTU/h at 5°F with a COP of 1.90, so it is still 1.9 times as efficient as electric resistance heat at that temperature.
- How much does the DIYCOOL ACIQ-55Z-HH-M5B cost to run per year?
- At its rated efficiency it costs about $1,181-$3,558 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,511 in Phoenix and $3,015 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- What refrigerant does the DIYCOOL ACIQ-55Z-HH-M5B use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 60,000 BTU models
- Cooper&Hunter CH-HPR55M-230VO · cold climate22.0 SEER2 · 9.5 HSPF2
- MDV M5OA-55HFN1-M-[X](2) · cold climate22.0 SEER2 · 9.5 HSPF2
- Comfort-Aire A-VMH55PV-1 · cold climate22.0 SEER2 · 9.5 HSPF2
- Hitachi HVAHP060C23S21.8 SEER2 · 9.8 HSPF2
- Fujitsu AOUK060MSAN7 · cold climate22.2 SEER2 · 9.5 HSPF2
- GE Appliances MWHQ060NC2AA · cold climate21.0 SEER2 · 11.0 HSPF2
- TOSOT TMV-V60WL/NHC-T(U) · cold climate22.5 SEER2 · 9.2 HSPF2
- GREE MUL60HP230V1R32AO21.0 SEER2 · 10.0 HSPF2
See all 44 60,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 25, 2026. How we use the data.