1.5-ton central heat pump · 7SHP15V Series
Ducane 7SHP15V18P-**A
Average cooling and heating efficiency for a 1.5-ton central heat pump, and certified for cold climates.
Ranks #70 of 170 1.5 ton central heat pumps for cooling efficiency, and costs about $559 a year to run in a mixed climate like Atlanta.
- SEER2
- 17.2 Cooling efficiency over a seasonAverage · beats 54%
- HSPF2
- 8.8 Heating efficiency over a seasonAverage · beats 49%
- EER2
- 10.6 Cooling efficiency on a 95°F dayBelow average · beats 19%
- Heat at 5°F
- 14,000 BTU/h74% of its 47°F outputBelow average · beats 39%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 14,000 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
- You want a choice of indoor units - 185 certified pairings.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | Ducane |
| Also sold as | Concord, ALLIED |
| Outdoor unit model | 7SHP15V18P-**A |
| Series | 7SHP15V Series |
| Type | Central heat pump |
| Nominal size | 1.5 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | February 6, 2026 |
| Last certified | July 16, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 17.2 (range 15.2-17.2) |
| EER2Efficiency at 95°F outdoors | 10.2-11.0 |
| Cooling capacity | 17,900-18,900 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.1-8.8 |
| Capacity at 47°F | 18,000-18,600 BTU/h |
| Capacity at 17°F | 15,000-15,600 BTU/h |
| Capacity at 5°F | 12,600-14,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.80-2.00 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 7EH30AX-**+TDR at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 185 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| 7EH30AX-**+TDR · cold climate | 80G2UH045AE12* | 17.2 | 10.6 | 8.8 | 13,700 | 218615518 |
| 7EH30AX-**+TDR · cold climate | 80G2UH045AE12* | 17.2 | 10.6 | 8.8 | 13,700 | 218619577 |
| 7EH30AX-**+TDR · cold climate | 80G2UH045AE12* | 17.2 | 10.6 | 8.8 | 13,700 | 218620337 |
| 7E[C,U]24BX-**+TDR · cold climate | 92G1UH030BE12* | 17.1 | 10.2 | 8.5 | 14,000 | 218615661 |
| 7E[C,U]24BX-**+TDR · cold climate | 92G1UH030BE12* | 17.1 | 10.2 | 8.5 | 14,000 | 218619720 |
| 7E[C,U]24BX-**+TDR · cold climate | 92G1UH030BE12* | 17.1 | 10.2 | 8.5 | 14,000 | 218620480 |
| 7EH24BX-**+TDR · cold climate | 80G2UH090BE12* | 16.8 | 10.6 | 8.4 | 13,900 | 218615672 |
| 7EH24BX-**+TDR · cold climate | 80G2UH090BE12* | 16.8 | 10.6 | 8.4 | 13,900 | 218619731 |
| 7EH24BX-**+TDR · cold climate | 80G2UH090BE12* | 16.8 | 10.6 | 8.4 | 13,900 | 218620491 |
| 7EH30BX-**+TDR · cold climate | 80G2UH090BE12* | 16.7 | 10.6 | 8.4 | 13,900 | 218615679 |
| 7EH30BX-**+TDR · cold climate | 80G2UH090BE12* | 16.7 | 10.6 | 8.4 | 13,900 | 218619738 |
| 7EH30BX-**+TDR · cold climate | 80G2UH090BE12* | 16.7 | 10.6 | 8.4 | 13,900 | 218620498 |
| 7EH30AX-**+TDR · cold climate | 80G2UH070AE12L* | 16.5 | 10.5 | 8.6 | 13,800 | 218615678 |
| 7EH30AX-**+TDR · cold climate | 80G2UH070AE12* | 16.5 | 10.5 | 8.6 | 13,800 | 218615519 |
| 7EH30AX-**+TDR · cold climate | 80G2UH070AE12L* | 16.5 | 10.5 | 8.6 | 13,800 | 218619737 |
| 7EH30AX-**+TDR · cold climate | 80G2UH070AE12* | 16.5 | 10.5 | 8.6 | 13,800 | 218619578 |
| 7EH30AX-**+TDR · cold climate | 80G2UH070AE12* | 16.5 | 10.5 | 8.6 | 13,800 | 218620338 |
| 7EH30AX-**+TDR · cold climate | 80G2UH070AE12L* | 16.5 | 10.5 | 8.6 | 13,800 | 218620497 |
| 7EH24BX-**+TDR · cold climate | 92G1UH030BE12* | 16.5 | 10.4 | 8.4 | 13,900 | 218615675 |
| 7EH24BX-**+TDR · cold climate | 92G1UH030BE12* | 16.5 | 10.4 | 8.4 | 13,900 | 218619734 |
| 7EH24BX-**+TDR · cold climate | 92G1UH030BE12* | 16.5 | 10.4 | 8.4 | 13,900 | 218620494 |
| 7AH1AV24PX- · cold climate | - | 16.2 | 10.7 | 8.7 | 13,400 | 218615126 |
| 7AH1AV24PX- · cold climate | - | 16.2 | 10.7 | 8.7 | 13,400 | 218615083 |
| 7AH1AV24PX- · cold climate | - | 16.2 | 10.7 | 8.7 | 13,400 | 218615040 |
| 7EH30AX-**+TDR · cold climate | 80G1UH045AE12L* | 16.2 | 10.6 | 8.6 | 13,800 | 218615521 |
| 7EH30AX-**+TDR · cold climate | 80G1UH045AE12* | 16.2 | 10.6 | 8.6 | 13,800 | 218615520 |
| 7EH30AX-**+TDR · cold climate | 80G1UH045AE12L* | 16.2 | 10.6 | 8.6 | 13,800 | 218619580 |
| 7EH30AX-**+TDR · cold climate | 80G1UH045AE12* | 16.2 | 10.6 | 8.6 | 13,800 | 218619579 |
| 7EH30AX-**+TDR · cold climate | 80G1UH045AE12L* | 16.2 | 10.6 | 8.6 | 13,800 | 218620340 |
| 7EH30AX-**+TDR · cold climate | 80G1UH045AE12* | 16.2 | 10.6 | 8.6 | 13,800 | 218620339 |
| 7AH1AV18PX-230- · cold climate | - | 16.2 | 11.0 | 8.5 | 12,600 | 218083038 |
| 7AH1AV18PX-230- · cold climate | - | 16.2 | 11.0 | 8.5 | 12,600 | 218083037 |
| 7AH1AV18PX-230- · cold climate | - | 16.2 | 11.0 | 8.5 | 12,600 | 218083036 |
| 7AH1AV18PX- · cold climate | - | 16.2 | 11.0 | 8.5 | 12,600 | 218615953 |
| 7AH1AV18PX- · cold climate | - | 16.2 | 11.0 | 8.5 | 12,600 | 218615946 |
| 7EH24AX-**+TDR · cold climate | 80G2UH045AE12* | 16.2 | 10.4 | 8.4 | 13,900 | 218615508 |
| 7EH24AX-**+TDR · cold climate | 80G2UH045AE12* | 16.2 | 10.4 | 8.4 | 13,900 | 218619567 |
| 7EH24AX-**+TDR · cold climate | 80G2UH045AE12* | 16.2 | 10.4 | 8.4 | 13,900 | 218620327 |
| 7AH1RE24DX- · cold climate | - | 16.1 | 10.5 | 8.8 | 13,600 | 218615124 |
| 7AH1RE18DX- · cold climate | - | 16.1 | 10.5 | 8.8 | 13,600 | 218615123 |
| 7AH1RE24DX- · cold climate | - | 16.1 | 10.5 | 8.8 | 13,600 | 218615081 |
| 7AH1RE18DX- · cold climate | - | 16.1 | 10.5 | 8.8 | 13,600 | 218615080 |
| 7AH1RE24DX- · cold climate | - | 16.1 | 10.5 | 8.8 | 13,600 | 218615038 |
| 7AH1RE18DX- · cold climate | - | 16.1 | 10.5 | 8.8 | 13,600 | 218615037 |
| 7AH1AE24PX- · cold climate | - | 16.1 | 10.6 | 8.7 | 13,500 | 218615125 |
| 7AH1AE24PX- · cold climate | - | 16.1 | 10.6 | 8.7 | 13,500 | 218615082 |
| 7AH1AE24PX- · cold climate | - | 16.1 | 10.6 | 8.7 | 13,500 | 218615039 |
| 7EH30BX-**+TDR · cold climate | 92G1UH070BE12* | 16.0 | 10.5 | 8.3 | 13,900 | 218615684 |
| 7EH24BX-**+TDR · cold climate | 92G1UH070BE12* | 16.0 | 10.5 | 8.3 | 13,900 | 218615677 |
| 7EH30BX-**+TDR · cold climate | 92G1UH070BE12* | 16.0 | 10.5 | 8.3 | 13,900 | 218619743 |
| 7EH24BX-**+TDR · cold climate | 92G1UH070BE12* | 16.0 | 10.5 | 8.3 | 13,900 | 218619736 |
| 7EH30BX-**+TDR · cold climate | 92G1UH070BE12* | 16.0 | 10.5 | 8.3 | 13,900 | 218620503 |
| 7EH24BX-**+TDR · cold climate | 92G1UH070BE12* | 16.0 | 10.5 | 8.3 | 13,900 | 218620496 |
| 7E[C,U]30AX-**+TDR · cold climate | 80G2UH070AE12L* | 16.0 | 10.4 | 8.2 | 13,900 | 218615664 |
| 7E[C,U]30AX-**+TDR · cold climate | 80G2UH070AE12* | 16.0 | 10.4 | 8.2 | 13,900 | 218615499 |
| 7E[C,U]30AX-**+TDR · cold climate | 80G2UH070AE12L* | 16.0 | 10.4 | 8.2 | 13,900 | 218619723 |
| 7E[C,U]30AX-**+TDR · cold climate | 80G2UH070AE12* | 16.0 | 10.4 | 8.2 | 13,900 | 218619558 |
| 7E[C,U]30AX-**+TDR · cold climate | 80G2UH070AE12L* | 16.0 | 10.4 | 8.2 | 13,900 | 218620483 |
| 7E[C,U]30AX-**+TDR · cold climate | 80G2UH070AE12* | 16.0 | 10.4 | 8.2 | 13,900 | 218620318 |
| 7EH30BX-**+TDR · cold climate | 92G1UH045BE12* | 15.9 | 10.4 | 8.3 | 13,900 | 218615683 |
Yearly running cost in 10 large cities
- Phoenix, AZ$620/yr
- Miami, FL$505/yr
- Houston, TX$556/yr
- Atlanta, GA$559/yr
- Los Angeles, CA$543/yr
- New York, NY$1,332/yr
- Chicago, IL$1,081/yr
- Denver, CO$898/yr
- Seattle, WA$551/yr
- Minneapolis, MN$1,111/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Ducane 7SHP15V18P-**A?
- The Ducane 7SHP15V18P-**A is rated at up to 17.2 SEER2 and 10.6 EER2 for cooling and up to 8.8 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 185 certified matchups SEER2 ranges from 15.2-17.2.
- Is the Ducane 7SHP15V18P-**A good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 14,000 BTU/h at 5°F with a COP of 2.00, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
- How much does the Ducane 7SHP15V18P-**A cost to run per year?
- At its rated efficiency it costs about $505-$1,332 a year in electricity in large U.S. cities, depending on climate and local rates - for example $620 in Phoenix and $1,111 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Ducane 7SHP15V18P-**A?
- ENERGY STAR lists 185 certified combinations for this outdoor unit. The highest-rated ones use 7EH30AX-**+TDR, 7E[C,U]24BX-**+TDR, 7EH24BX-**+TDR.
- What refrigerant does the Ducane 7SHP15V18P-**A use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 1.5 ton models
- MRCOOL DIYH-18-HP-C-230C25 · cold climate17.5 SEER2 · 10.0 HSPF2
- Lennox ML15KSPV-018-230A · cold climate17.2 SEER2 · 8.8 HSPF2
- Midea MDV-V18WMN10T · cold climate17.5 SEER2 · 10.0 HSPF2
- AC Pro AOX430U-18HFN1-M · cold climate17.0 SEER2 · 9.5 HSPF2
- TOSOT TUD18-12W2/NHE-D(U) · cold climate18.0 SEER2 · 9.0 HSPF2
- TCL H18TDHXPC · cold climate17.0 SEER2 · 9.5 HSPF2
- TOSOT TU18-R32WEDU · cold climate18.0 SEER2 · 9.0 HSPF2
- Jetson HP-18ODU-001 · cold climate17.0 SEER2 · 9.3 HSPF2
See all 170 1.5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 16, 2026. How we use the data.