3-ton central heat pump · DRU Series

DuraSTAR DRU1H36S2A

Average cooling efficiency and excellent heating efficiency for a 3-ton central heat pump, and certified for cold climates.

Ranks #134 of 302 3 ton central heat pumps for cooling efficiency, and costs about $985 a year to run in a mixed climate like Atlanta.

SEER2
17.4 Cooling efficiency over a season
Average · beats 55%
HSPF2
10.3 Heating efficiency over a season
Excellent · beats 92%
EER2
11.7 Cooling efficiency on a 95°F day
Average · beats 43%
Heat at 5°F
39,000 BTU/h105% of its 47°F output
Below average · beats 20%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 39,000 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 92% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 47 certified pairings.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications3 ton, R-454B
General
BrandDuraSTAR
Outdoor unit modelDRU1H36S2A
SeriesDRU Series
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceDecember 8, 2020
Last certifiedMarch 11, 2026
Cooling
SEER2Seasonal efficiency, higher is better17.4 (range 15.2-17.4)
EER2Efficiency at 95°F outdoors10.1-11.7
Cooling capacity34,000-36,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.4-10.3
Capacity at 47°F35,000-38,000 BTU/h
Capacity at 17°F27,000-31,800 BTU/h
Capacity at 5°F31,000-39,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.75-1.90
ENERGY STAR cold climateYes
Heating output as it gets colder105% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with DRUM3036S2A at the standard test temperatures, in BTU/h:

Certified matchups47 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
DRUM3036S2A · cold climate-17.411.710.339,000215374887
DRUF3622S2A · cold climate-16.811.29.634,600217465409
DRUC3621S2A · cold climateRL18100C20MPS116.811.49.634,000218072091
DRUC3621S2A · cold climateRL18100C16MPS116.711.49.534,000218072090
DRUC3621S2A · cold climateRL18080C16MPS116.710.99.534,000218072089
DRUC3617S2A · cold climateRL18080B12MPS116.410.69.434,000218072088
DRUC3621S2A · cold climateRG19080C16MPS116.310.79.234,000218072034
DRUC3617S2A · cold climateMGV96U060B3C16.310.89.233,000218071742
DRUC3621S2A · cold climateS9V2C100U5VS***16.211.09.333,000218071885
DRUC3621S2A · cold climateS9V2C100D5VS***16.211.09.333,000218071884
DRUC3621S2A · cold climateML296UH110XV60C*16.111.09.533,000218072313
DRUC3621S2A · cold climateS9V2C080U5VS***16.010.99.433,000218071883
DRUC3621S2A · cold climateMGV96U080C4C16.011.09.333,000218071744
DRUC3617S2A · cold climateMGV96U080B3C16.010.79.133,000218071743
DRUC3621S2A · cold climateRG19100C20MPS115.911.19.234,000218072037
DRUC3614S2A · cold climateRL18040A12MPS115.910.28.532,000218072086
DRUC3617S2A · cold climate-15.810.79.436,000217493437
DRUC3621S2A · cold climate-15.810.79.436,000217493439
DRUC3621S2A · cold climateRG19080C20MPS115.810.79.434,000218072035
DRUC3621S2A · cold climateML196UH090XE36C*15.810.79.233,000218072308
DRUC3621S2A · cold climateS9X2C080U5PSB**15.610.69.333,000218071978
DRUC3621S2A · cold climateS9X1C080U5PSB**15.610.69.333,000218071892
DRUC3621S2A · cold climateML193UH090XE36C*15.610.79.233,000218072304
DRUC3617S2A · cold climateS9V2B080U4VS***15.510.49.233,000218071718
DRUC3621S2A · cold climateML296UH090XV48B*15.510.79.133,000218072312
DRUC3621S2A · cold climateML296UH090XV48C*15.510.79.133,000218072404
DRUC3614S2A · cold climateRG19060A10MPS115.510.18.432,000218072033
DRUC3621S2A · cold climateRG19100C16MPS115.411.09.234,000218072036
DRUC3617S2A · cold climateML193DF070XE36B*15.410.59.133,000218072301
DRUC3617S2A · cold climateML196UH070XE36B*15.410.58.731,000218072306
DRUC3617S2A · cold climateRG19080B12MPS115.310.69.635,000218071725
DRUC3617S2A · cold climateRG19060B12MPS115.310.69.534,000218071723
DRUC3621S2A · cold climateML193DF090XE48C*15.310.79.333,000218072395
DRUC3621S2A · cold climateML193DF090XE48B*15.310.79.333,000218072303
DRUC3621S2A · cold climateML296DF090XV60C*15.310.69.233,000218072311
DRUC3621S2A · cold climateML196DF090XE48C*15.310.89.132,000218072400
DRUC3621S2A · cold climateML196DF090XE48B*15.310.89.132,000218072307
DRUC3617S2A · cold climateML193UH070XE36B*15.310.49.033,000218072302
DRUC3617S2A · cold climateS9V2B040U3VS***15.310.38.933,000218071715
DRUC3621S2A · cold climateML196UH090XE48C*15.210.79.333,000218072402
DRUC3621S2A · cold climateML193UH090XE48C*15.210.79.333,000218072397
DRUC3621S2A · cold climateML196UH090XE48B*15.210.79.333,000218072309
DRUC3621S2A · cold climateML193UH090XE48B*15.210.79.333,000218072305
DRUC3621S2A · cold climateMGV96U100C5C15.211.09.334,000218071745
DRUC3617S2A · cold climateS9V2B060D3VS***15.210.39.033,000218071717
DRUC3617S2A · cold climateS9V2B060U4VS***15.210.39.033,000218071716
DRUC3617S2A · cold climateML296DF070XV48B*15.210.38.933,000218072310
Yearly running cost in 10 large cities$925-$2,283

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the DuraSTAR DRU1H36S2A?
The DuraSTAR DRU1H36S2A is rated at up to 17.4 SEER2 and 11.7 EER2 for cooling and up to 10.3 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 47 certified matchups SEER2 ranges from 15.2-17.4.
Is the DuraSTAR DRU1H36S2A good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 39,000 BTU/h at 5°F with a COP of 1.90, so it is still 1.9 times as efficient as electric resistance heat at that temperature.
How much does the DuraSTAR DRU1H36S2A cost to run per year?
At its rated efficiency it costs about $925-$2,283 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,151 in Phoenix and $1,875 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the DuraSTAR DRU1H36S2A?
ENERGY STAR lists 47 certified combinations for this outdoor unit. The highest-rated ones use DRUM3036S2A, DRUF3622S2A, DRUC3621S2A.
What refrigerant does the DuraSTAR DRU1H36S2A use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,120/yrYou save $737/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump DuraSTAR DRU1H36S2A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,120
Current system, per year
$1,856
You save per year
$737
Payback
18.3 years
Net after 10 years
-$6,135

Cooling $728Heating $391Electricity used: 6,998 kWhSaved vs. a minimum-efficiency heat pump: $304

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of March 11, 2026. How we use the data.