HVAC Rated

2.5-ton central heat pump · TDi Pro

ECOER EODA19H-2436AA

Excellent cooling efficiency and very good heating efficiency for a 2.5-ton central heat pump, and certified for cold climates.

Ranks #4 of 199 2.5 ton central heat pumps for cooling efficiency, and costs about $863 a year to run in a mixed climate like Atlanta.

SEER2
20.5 Cooling efficiency over a season
Excellent · beats 96%
HSPF2
9.5 Heating efficiency over a season
Very good · beats 70%
EER2
13.0 Cooling efficiency on a 95°F day
Very good · beats 89%
Heat at 5°F
25,200 BTU/h82% of its 47°F output
Average · beats 58%

A good fit if…

  • You want low cooling bills - its SEER2 beats 96% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 25,200 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 70% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications2.5 ton, R-410A
General
BrandECOER
Also sold asYISO
Outdoor unit modelEODA19H-2436AA
SeriesTDi Pro
TypeCentral heat pump
Nominal size2.5 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceApril 10, 2024
Last certifiedAugust 5, 2026
Cooling
SEER2Seasonal efficiency, higher is better20.5 (range 15.2-20.5)
EER2Efficiency at 95°F outdoors10.8-13.0
Cooling capacity22,800-34,200 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.3-9.5
Capacity at 47°F23,000-36,000 BTU/h
Capacity at 17°F21,000-28,000 BTU/h
Capacity at 5°F18,600-25,200 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.90-2.10
ENERGY STAR cold climateYes
Heating output as it gets colder82% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with EAHATN-24BA at the standard test temperatures, in BTU/h:

Certified matchups35 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
EAHATN-24BA · cold climate-20.513.09.519,600214660539
EAHDEN-24AB · cold climate-20.513.09.519,600216558237
EAHATN-36BA · cold climate-19.512.09.525,200214660540
EAHDEN-36AB · cold climate-19.512.09.525,200216558238
EAHAEC-24 · cold climate-19.212.29.219,000215447638
GNC4248CPT · cold climateMGH96M080C4A18.511.79.024,400214660556
GNC2430BPT · cold climateMGH96M060B3A18.512.09.019,400214660552
GNC2430APT · cold climateMGH96M060B3A18.512.09.019,200214660551
GNC2430BPT · cold climateMGH96M080B3A18.512.09.019,400214660550
GNC2430APT · cold climateMGH96M080B3A18.512.09.019,200214660549
GNC2430APT · cold climateFG7TC-060D-V24B*18.512.09.019,200215447628
GNC2430BPT · cold climateFG7TC-060D-V24B*18.512.09.019,400215447629
GNC4248CPTFG7TC-100D-V35C*18.511.79.022,400215447631
GNC4248CPTFG7TC-080D-V35C*18.511.79.022,400215447632
EAHAEC-36 · cold climate-18.211.79.524,600215447639
GNC3036BPT · cold climateMGH96M060B3A18.011.09.024,400214660554
GNC3036BPT · cold climateMGH96M080B3A18.011.09.024,400214660553
GNC3036BPT · cold climateFG7TC-060D-V24B*18.011.09.024,400215447630
SNC36CPT · cold climateFG7TC-080D-V35C*18.011.09.024,400217477692
SNC36CPT · cold climateMGH96M080C4A18.011.09.024,400217477694
GNC4248CPT · cold climateMGH96M100C5A17.511.78.824,400214660555
GNC2430BPT · cold climateFG7SA-072C-T24B*17.512.08.519,400214838769
GNC2430BPT · cold climateFG7SA-090C-T24B*17.512.08.519,400214838770
GNC2430APT · cold climateFG7SA-054C-T23A*17.512.08.519,200214838768
GNC4248CPTFG7SA-090C-T35C*17.011.78.522,400214838774
GNC4248CPTFG7SA-108C-T35C*17.011.78.322,400214838773
GNC3036BPT · cold climateFG7SA-090C-T24B*16.511.08.524,400214838771
GNC3036BPT · cold climateFG7SA-072C-T24B*16.511.08.524,400214838772
SNC36CPT · cold climate-16.011.09.023,600217477691
GNC2430BPT · cold climate-16.011.28.818,600216706470
GNC3036BPT · cold climate-16.011.08.823,600216706471
GNC2430APT · cold climate-16.011.28.618,600216706469
GNC3036BPT+DK · cold climate-15.210.88.823,600214660545
GNC2430BPT+DK · cold climate-15.211.78.818,600214660544
GNC2430APT+DK · cold climate-15.211.78.618,600214660543
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the ECOER EODA19H-2436AA: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$670-$2,146

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the ECOER EODA19H-2436AA?
The ECOER EODA19H-2436AA is rated at up to 20.5 SEER2 and 13.0 EER2 for cooling and up to 9.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 35 certified matchups SEER2 ranges from 15.2-20.5.
Is the ECOER EODA19H-2436AA good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 25,200 BTU/h at 5°F with a COP of 2.10, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
How much does the ECOER EODA19H-2436AA cost to run per year?
At its rated efficiency it costs about $670-$2,146 a year in electricity in large U.S. cities, depending on climate and local rates - for example $875 in Phoenix and $1,831 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the ECOER EODA19H-2436AA the same as the YISO YOHA2-36AA?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the ECOER EODA19H-2436AA?
ENERGY STAR lists 35 certified combinations for this outdoor unit. The highest-rated ones use EAHATN-24BA, EAHDEN-24AB, EAHATN-36BA.
What refrigerant does the ECOER EODA19H-2436AA use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $894/yrYou save $677/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump ECOER EODA19H-2436AA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$894
Current system, per year
$1,571
You save per year
$677
Payback
16.3 years
Net after 10 years
-$4,235

Cooling $498Heating $396Electricity used: 5,588 kWhSaved vs. a minimum-efficiency heat pump: $322

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2.5 ton models

See all 199 2.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of August 5, 2026. How we use the data.