9,000 BTU mini-split heat pump · DE-series
Elios DEA09HOS28230E8
Very good cooling and heating efficiency for a 9,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #162 of 395 9,000 BTU mini-splits for cooling efficiency, and costs about $209 a year to run in a mixed climate like Atlanta.
- SEER2
- 25.0 Cooling efficiency over a seasonVery good · beats 83%
- HSPF2
- 12.0 Heating efficiency over a seasonVery good · beats 89%
- EER2
- 15.6 Cooling efficiency on a 95°F dayExcellent · beats 94%
- Heat at 5°F
- 10,800 BTU/h85% of its 47°F outputBelow average · beats 27%
A good fit if…
- You want low cooling bills - its SEER2 beats 83% of mini-splits.
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 10,800 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 89% of mini-splits.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | Elios |
| Outdoor unit model | DEA09HOS28230E8 |
| Series | DE-series |
| Type | Mini-split heat pump |
| Nominal size | 9,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | January 26, 2019 |
| Last certified | May 12, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 25.0 (range 20.2-25.0) |
| EER2Efficiency at 95°F outdoors | 13.0-15.6 |
| Cooling capacity | 9,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 10.3-12.0 |
| Capacity at 47°F | 9,800-11,500 BTU/h |
| Capacity at 17°F | 7,100-10,100 BTU/h |
| Capacity at 5°F | 9,800-10,800 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.59-1.90 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with DE09HIW23230E3 at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| DE09HIW23230E3 ELIOS | 25.0 | 15.6 | 11.0 | 9,800 | 208119828 |
| DUA09HICU230X5 ELIOS · cold climate | 20.5 | 13.0 | 10.3 | 10,000 | 207742439 |
| DUA09HICU230X5 ELIOS · cold climate | 20.5 | 13.0 | 10.3 | 10,000 | 207742439 |
| DUA09HIDU230X5 ELIOS · cold climate | 20.2 | 13.2 | 12.0 | 10,800 | 207742452 |
Yearly running cost in 10 large cities
- Phoenix, AZ$218/yr
- Miami, FL$170/yr
- Houston, TX$195/yr
- Atlanta, GA$209/yr
- Los Angeles, CA$206/yr
- New York, NY$512/yr
- Chicago, IL$418/yr
- Denver, CO$350/yr
- Seattle, WA$217/yr
- Minneapolis, MN$434/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Elios DEA09HOS28230E8?
- The Elios DEA09HOS28230E8 is rated at up to 25.0 SEER2 and 15.6 EER2 for cooling and up to 12.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 4 certified matchups SEER2 ranges from 20.2-25.0.
- Is the Elios DEA09HOS28230E8 good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 10,800 BTU/h at 5°F with a COP of 1.90, so it is still 1.9 times as efficient as electric resistance heat at that temperature.
- How much does the Elios DEA09HOS28230E8 cost to run per year?
- At its rated efficiency it costs about $170-$512 a year in electricity in large U.S. cities, depending on climate and local rates - for example $218 in Phoenix and $434 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Elios DEA09HOS28230E8?
- ENERGY STAR lists 4 certified combinations for this outdoor unit. The highest-rated ones use ELIOS DE09HIW23230E3, ELIOS DUA09HICU230X5, ELIOS DUA09HIDU230X5.
- What refrigerant does the Elios DEA09HOS28230E8 use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 9,000 BTU models
- Midea MO1ES-H09B-1A · cold climate25.4 SEER2 · 10.0 HSPF2
- Goodman MSH093E23MCAA · cold climate25.0 SEER2 · 12.0 HSPF2
- Blueridge BMS925XC · cold climate25.4 SEER2 · 10.0 HSPF2
- Friedrich FPHSR09A3B · cold climate25.0 SEER2 · 11.0 HSPF2
- CanAir 4C25SCH09H11 · cold climate25.4 SEER2 · 10.7 HSPF2
- Friedrich FPHSR09A3D · cold climate25.0 SEER2 · 11.0 HSPF2
- Innovair WIN09H7H51(O) · cold climate25.5 SEER2 · 10.5 HSPF2
- Hisense AO-09U3T25U · cold climate25.0 SEER2 · 11.0 HSPF2
See all 395 9,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 12, 2026. How we use the data.