Under 1.5-ton packaged heat pump · AIO P Series
Ephoca APE10N3H2
Average cooling efficiency and very good heating efficiency for a under 1.5-ton packaged heat pump, and certified for cold climates.
Ranks #2 of 9 Under 1.5 ton packaged heat pumps for cooling efficiency, and costs about $286 a year to run in a mixed climate like Atlanta.
- SEER2
- 15.8 Cooling efficiency over a seasonAverage · beats 64%
- HSPF2
- 8.6 Heating efficiency over a seasonVery good · beats 80%
- EER2
- 11.2 Cooling efficiency on a 95°F dayBelow average · beats 34%
- Heat at 5°F
- 5,600 BTU/h62% of its 47°F outputBelow average · beats 22%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 5,600 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 80% of packaged heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | Ephoca |
| Also sold as | Innova Srl, Innova |
| Outdoor unit model | APE10N3H2 |
| Series | AIO P Series |
| Type | Packaged heat pump |
| Nominal size | Under 1.5 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-32 |
| Connected (smart) capable | Yes |
| On the market since | August 11, 2025 |
| Last certified | June 4, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 15.8 (range 15.8) |
| EER2Efficiency at 95°F outdoors | 11.2 |
| Cooling capacity | 9,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.6 |
| Capacity at 47°F | 9,000 BTU/h |
| Capacity at 17°F | 7,600 BTU/h |
| Capacity at 5°F | 5,600 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.76 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| - · cold climate | 15.8 | 11.2 | 8.6 | 5,600 | 217607137 |
| - · cold climate | 15.8 | 11.2 | 8.6 | 5,600 | 218326926 |
| - · cold climate | 15.8 | 11.2 | 8.6 | 5,600 | 218329910 |
Same unit, other model numbers
These model numbers have exactly the same certified ratings and matchups as the Ephoca APE10N3H2: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.
- Ephoca APE10N4H2
- Ephoca APE10R3H2
- Ephoca APE10R4H2
- Ephoca APK10N3H2
- Ephoca APK10N4H2
- Ephoca APK10R3H2
- Ephoca APK10R4H2
- Ephoca APP10N3H1
- Ephoca APP10N3H2
- Ephoca APP10N4H1
- Ephoca APP10N4H2
- Ephoca APP10R3H1
- Ephoca APP10R3H2
- Ephoca APP10R4H1
- Ephoca APP10R4H2
- Ephoca APE10*3*2
- Ephoca APK10*3*2
- Ephoca APP10*3*1
- Ephoca APP10*3*2
Yearly running cost in 10 large cities
- Phoenix, AZ$325/yr
- Miami, FL$268/yr
- Houston, TX$291/yr
- Atlanta, GA$286/yr
- Los Angeles, CA$277/yr
- New York, NY$675/yr
- Chicago, IL$546/yr
- Denver, CO$453/yr
- Seattle, WA$277/yr
- Minneapolis, MN$560/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Ephoca APE10N3H2?
- The Ephoca APE10N3H2 is rated at up to 15.8 SEER2 and 11.2 EER2 for cooling and up to 8.6 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
- Is the Ephoca APE10N3H2 good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 5,600 BTU/h at 5°F with a COP of 1.76, so it is still 1.8 times as efficient as electric resistance heat at that temperature.
- How much does the Ephoca APE10N3H2 cost to run per year?
- At its rated efficiency it costs about $268-$675 a year in electricity in large U.S. cities, depending on climate and local rates - for example $325 in Phoenix and $560 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Is the Ephoca APE10N3H2 the same as the Ephoca APE10N4H2?
- Yes, as far as the certified ratings go. ENERGY STAR lists 20 model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
- What refrigerant does the Ephoca APE10N3H2 use?
- It uses R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar Under 1.5 ton models
- Multi MFG 12SPV0-HP-X-D · cold climate17.1 SEER2 · 8.6 HSPF2
- Innova APE10N3H1-3 · cold climate15.8 SEER2 · 8.6 HSPF2
- Innova Srl C3NS15IC3UC · cold climate15.8 SEER2 · 8.6 HSPF2
- Multi MFG 9SPV0-HP-X-D · cold climate15.2 SEER2 · 8.9 HSPF2
- Ephoca AVK19N3H2 · cold climate15.4 SEER2 · 9.2 HSPF2
- Ephoca AVE09N3H2 · cold climate15.4 SEER2 · 9.9 HSPF2
- Ephoca ADE09N3H2 · cold climate15.3 SEER2 · 9.2 HSPF2
- Ephoca AWE09N3H2 · cold climate15.2 SEER2 · 8.6 HSPF2
See all 9 Under 1.5 ton packaged heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 4, 2026. How we use the data.