HVAC Rated

1.5-ton central heat pump · F-SERIES PLUS

Friedrich FRP15AZ18AJ2N

Below average cooling and heating efficiency for a 1.5-ton central heat pump, but not rated for cold climates.

Ranks #109 of 170 1.5 ton central heat pumps for cooling efficiency, and costs about $559 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.1 Heating efficiency over a season
Below average · beats 20%
EER2
11.7 Cooling efficiency on a 95°F day
Average · beats 43%
Heat at 5°F
9,500 BTU/h54% of its 47°F output
Very good · beats 76%

A good fit if…

  • You want a choice of indoor units - 42 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications1.5 ton, R-410A
General
BrandFriedrich
Outdoor unit modelFRP15AZ18AJ2N
SeriesF-SERIES PLUS
TypeCentral heat pump
Nominal size1.5 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceFebruary 27, 2023
Last certifiedJune 3, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors11.7
Cooling capacity17,100 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.1
Capacity at 47°F17,100 BTU/h
Capacity at 17°F11,000-12,300 BTU/h
Capacity at 5°F8,100-9,500 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.90-2.20
ENERGY STAR cold climateNo
Heating output as it gets colder54% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FRH2VZ2417STANN at the standard test temperatures, in BTU/h:

Certified matchups42 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
FRH2VZ2417STANN-16.011.78.19,200213382066
TCFZ2417STANMFR802V0503A14UH16.011.78.19,300213841805
TCFZ2417STANMFR951V0403A17M416.011.78.19,300213841771
TCFZ2417STANMFR921V0403A17M416.011.78.19,300213841777
TCFZ2417STANMFR962V0403A17M416.011.78.19,300213841788
TCFZ2417STANMFR801V0503A14DZ16.011.78.19,300213841798
TCFZ2417STANMFR802V0503A14DZ16.011.78.19,300213841803
TCFZ2417STANMFR801V0503A14UH16.011.78.19,300213841802
RCFZ2417STANMFR801V0503A14UH16.011.78.19,300214327611
RCFZ2417STANMFR802V0503A14UH16.011.78.19,300214327613
RCFZ2417STANMFR951V0403A17M416.011.78.19,300214327596
RCFZ2417STANMFR802V0503A14DZ16.011.78.19,300214327612
RCFZ2417STANMFR962V0403A17M416.011.78.19,300214327605
RCFZ2417STANMFR921V0403A17M416.011.78.19,300214327600
RCFZ2417STANMFR801V0503A14DZ16.011.78.19,300214327610
RF2TZ2421STANS-16.011.77.88,300213841793
FRH3VZ2417STACN-16.011.77.88,100214664592
TCFZ2417STANMFR801V0504A17UHU15.211.78.19,400213841807
TCFZ2417STANMFR802V0754A17DZ15.211.78.19,300213841809
TCFZ2417STANMFR951V0603A17M415.211.78.19,400213841767
TCFZ2417STANMFR921V0603A17M415.211.78.19,400213841775
TCFZ2417STANMFR951V0403A17UHU15.211.78.19,500213841781
TCFZ2417STANMFR921V0703A17M415.211.78.19,300213841776
TCFZ2417STANMFR951V0703A17M415.211.78.19,300213841780
TCFZ2417STANMFR951V0603A17UHU15.211.78.19,500213841778
TCFZ2417STANMFR962V0603A17M415.211.78.19,400213841790
TCFZ2417STANMFR801V0754A17DZ15.211.78.19,300213841796
TCFZ2417STANMFR801V0704A17UHU15.211.78.19,300213841795
TCFZ2417STANMFR962V0703A17M415.211.78.19,300213841792
RCFZ2417STANMFR801V0504A17UHU15.211.78.19,400214327614
RCFZ2417STANMFR951V0603A17M415.211.78.19,400214327594
RCFZ2417STANMFR921V0603A17M415.211.78.19,400214327598
RCFZ2417STANMFR962V0703A17M415.211.78.19,300214327607
RCFZ2417STANMFR962V0603A17M415.211.78.19,400214327606
RCFZ2417STANMFR801V0754A17DZ15.211.78.19,300214327609
RCFZ2417STANMFR951V0703A17M415.211.78.19,300214327603
RCFZ2417STANMFR801V0704A17UHU15.211.78.19,300214327608
RCFZ2417STANMFR921V0703A17M415.211.78.19,300214327599
RCFZ2417STANMFR802V0754A17DZ15.211.78.19,300214327615
RCFZ2417STANMFR951V0403A17UHU15.211.78.19,500214327604
RCFZ2417STANMFR951V0603A17UHU15.211.78.19,500214327601
FRH2TZ2417STANN-15.211.77.88,200213087937
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the Friedrich FRP15AZ18AJ2N: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$502-$1,335

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the Friedrich FRP15AZ18AJ2N?
The Friedrich FRP15AZ18AJ2N is rated at up to 16.0 SEER2 and 11.7 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 42 certified matchups SEER2 ranges from 15.2-16.0.
Is the Friedrich FRP15AZ18AJ2N good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 1.5-ton model.
How much does the Friedrich FRP15AZ18AJ2N cost to run per year?
At its rated efficiency it costs about $502-$1,335 a year in electricity in large U.S. cities, depending on climate and local rates - for example $618 in Phoenix and $1,115 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the Friedrich FRP15AZ18AJ2N the same as the Friedrich FWP15AZ18AJ2N?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the Friedrich FRP15AZ18AJ2N?
ENERGY STAR lists 42 certified combinations for this outdoor unit. The highest-rated ones use FRH2VZ2417STANN, TCFZ2417STANM, RCFZ2417STANM.
What refrigerant does the Friedrich FRP15AZ18AJ2N use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $613/yrYou save $269/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Friedrich FRP15AZ18AJ2N
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$613
Current system, per year
$882
You save per year
$269
Payback
24.2 years
Net after 10 years
-$3,809

Cooling $376Heating $236Electricity used: 3,829 kWhSaved vs. a minimum-efficiency heat pump: $64

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 1.5 ton models

See all 170 1.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 3, 2026. How we use the data.