HVAC Rated

4-ton central heat pump · K-SERIES

Friedrich FRP19AY48AJVC

Very good cooling and heating efficiency for a 4-ton central heat pump, but not rated for cold climates.

Ranks #40 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,223 a year to run in a mixed climate like Atlanta.

SEER2
19.0 Cooling efficiency over a season
Very good · beats 85%
HSPF2
10.0 Heating efficiency over a season
Very good · beats 84%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
42,000 BTU/h92% of its 47°F output
Very good · beats 76%

A good fit if…

  • You want low cooling bills - its SEER2 beats 85% of central heat pumps.
  • It will heat most of the year - its HSPF2 beats 84% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 28 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.

Calculate my running cost

Details

Specifications4 ton, R-454B
General
BrandFriedrich
Outdoor unit modelFRP19AY48AJVC
SeriesK-SERIES
TypeCentral heat pump
Nominal size4 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableYes
On the market sinceSeptember 12, 2024
Last certifiedSeptember 16, 2026
Cooling
SEER2Seasonal efficiency, higher is better19.0 (range 18.0-19.0)
EER2Efficiency at 95°F outdoors11.7-12.0
Cooling capacity45,500 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.5-10.0
Capacity at 47°F45,500 BTU/h
Capacity at 17°F42,000-43,000 BTU/h
Capacity at 5°F34,800-42,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.10-2.20
ENERGY STAR cold climateNo
Heating output as it gets colder92% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FRHMVY4821SEACA at the standard test temperatures, in BTU/h:

Certified matchups28 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
FRHMVY4821SEACA-19.012.010.042,000215584441
TCFY4821SEAAMFR802V0754A17UH19.012.010.042,000216551796
TCFY4821SEAAMFR802V0755A21DZ19.012.010.041,500216551798
TCFY4821SEAAMFR802V1005A21DZ19.012.010.041,500216551801
TCFY4821SEAAMFR802V1005A21UH19.012.010.041,500216551803
TCFY4821SEAAMFR802V0754A17DZ19.011.710.042,000216551806
TCFY4821SEAAMFR802V0755A21UH19.012.010.042,000216551808
TCFY4821SEAAMFR97MV1005A21DH19.012.010.042,000216551813
TCFY4821SEAAMFR98MV0855A21UP19.012.010.042,000216551816
TCFY4821SEAAMFR962V0855A21M419.011.710.042,000216551819
TCFY4821SEAAMFR98MV1005A21UP19.011.710.042,000216551821
TCFY4821SEAAMFR97MV0855A21DH19.012.010.042,000216551824
RCFY4821SEAAMFR802V0754A17UH19.012.010.042,000216551827
RCFY4821SEAAMFR802V0755A21DZ19.012.010.041,500216551829
RCFY4821SEAAMFR802V1005A21DZ19.012.010.041,500216551849
RCFY4821SEAAMFR802V1005A21UH19.012.010.041,500216551851
RCFY4821SEAAMFR802V0754A17DZ19.011.710.042,000216551864
RCFY4821SEAAMFR802V0755A21UH19.012.010.042,000216551869
RCFY4821SEAAMFR97MV1005A21DH19.012.010.042,000216551879
RCFY4821SEAAMFR98MV0855A21UP19.012.010.042,000216551884
RCFY4821SEAAMFR98MV1005A21UP19.011.710.042,000216551894
RCFY4821SEAAMFR962V0855A21M419.011.710.042,000216551889
RCFY4821SEAAMFR97MV0855A21DH19.012.010.042,000216551903
RCFY4821SEAAMFR972V0855A21UPS19.012.08.534,800218728686
RCFY4821SEAAMFR972V0705A21UPS19.012.08.534,800218728685
TCFY4821SEAAMFR962V0705A21M418.012.010.042,000216551811
RCFY4821SEAAMFR962V0705A21M418.012.010.042,000216551874
RCFY4821SEAAMFR972V1005A21UPS18.012.08.535,000218728687
Yearly running cost in 10 large cities$1,124-$2,900

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Friedrich FRP19AY48AJVC?
The Friedrich FRP19AY48AJVC is rated at up to 19.0 SEER2 and 12.0 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 28 certified matchups SEER2 ranges from 18.0-19.0.
Is the Friedrich FRP19AY48AJVC good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 4-ton model.
How much does the Friedrich FRP19AY48AJVC cost to run per year?
At its rated efficiency it costs about $1,124-$2,900 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,371 in Phoenix and $2,412 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Friedrich FRP19AY48AJVC?
ENERGY STAR lists 28 certified combinations for this outdoor unit. The highest-rated ones use FRHMVY4821SEACA, TCFY4821SEAAM, RCFY4821SEAAM.
What refrigerant does the Friedrich FRP19AY48AJVC use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,353/yrYou save $994/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Friedrich FRP19AY48AJVC
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,353
Current system, per year
$2,346
You save per year
$994
Payback
17.1 years
Net after 10 years
-$7,065

Cooling $843Heating $510Electricity used: 8,453 kWhSaved vs. a minimum-efficiency heat pump: $447

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 4 ton models

See all 319 4 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 16, 2026. How we use the data.