9,000 BTU mini-split heat pump · Floating Air Select
Friedrich FSHSR09B1B
Below average cooling and heating efficiency for a 9,000 BTU mini-split heat pump, but not rated for cold climates.
Ranks #360 of 395 9,000 BTU mini-splits for cooling efficiency, and costs about $263 a year to run in a mixed climate like Atlanta.
- SEER2
- 20.0 Cooling efficiency over a seasonBelow average · beats 18%
- HSPF2
- 9.0 Heating efficiency over a seasonBelow average · beats 10%
- EER2
- 12.5 Cooling efficiency on a 95°F dayAverage · beats 44%
- Heat at 5°F
- 6,000 BTU/h63% of its 47°F outputAverage · beats 48%
A good fit if…
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- Cooling cost matters most - its SEER2 is below average for mini-splits.
- You mainly need heat - its HSPF2 is below average for mini-splits.
Details
Specifications
| General | |
|---|---|
| Brand | Friedrich |
| Also sold as | Hisense, Innovair, OLMO |
| Outdoor unit model | FSHSR09B1B |
| Series | Floating Air Select |
| Type | Mini-split heat pump |
| Nominal size | 9,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-32 |
| Connected (smart) capable | No |
| On the market since | August 11, 2025 |
| Last certified | January 14, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 20.0 (range 20.0) |
| EER2Efficiency at 95°F outdoors | 12.5 |
| Cooling capacity | 9,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.0 |
| Capacity at 47°F | 9,500 BTU/h |
| Capacity at 17°F | 6,800 BTU/h |
| Capacity at 5°F | 6,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.00 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FAHSW09A1C at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| FAHSW09A1C FRIEDRICH | 20.0 | 12.5 | 9.0 | 6,000 | 217650063 |
Same unit, other model numbers
These model numbers have exactly the same certified ratings and matchups as the Friedrich FSHSR09B1B: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.
Yearly running cost in 10 large cities
- Phoenix, AZ$273/yr
- Miami, FL$213/yr
- Houston, TX$245/yr
- Atlanta, GA$263/yr
- Los Angeles, CA$259/yr
- New York, NY$647/yr
- Chicago, IL$529/yr
- Denver, CO$443/yr
- Seattle, WA$274/yr
- Minneapolis, MN$549/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Friedrich FSHSR09B1B?
- The Friedrich FSHSR09B1B is rated at up to 20.0 SEER2 and 12.5 EER2 for cooling and up to 9.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
- Is the Friedrich FSHSR09B1B good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 9,000 BTU model.
- How much does the Friedrich FSHSR09B1B cost to run per year?
- At its rated efficiency it costs about $213-$647 a year in electricity in large U.S. cities, depending on climate and local rates - for example $273 in Phoenix and $549 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Is the Friedrich FSHSR09B1B the same as the Hisense AO-09U1R25SS?
- Yes, as far as the certified ratings go. ENERGY STAR lists 6 model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
- Which indoor units work with the Friedrich FSHSR09B1B?
- ENERGY STAR lists 1 certified combination for this outdoor unit. The highest-rated one uses FRIEDRICH FAHSW09A1C.
- What refrigerant does the Friedrich FSHSR09B1B use?
- It uses R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 9,000 BTU models
- Daikin RXQ09ASBU20.0 SEER2 · 9.0 HSPF2
- York YRACDJ09WHAA20.0 SEER2 · 9.2 HSPF2
- Hisense AO-09U3R26SS20.0 SEER2 · 9.0 HSPF2
- Hitachi RAC-DJ09WHAA20.0 SEER2 · 9.2 HSPF2
- AUX AH09MHA3DI-20US · cold climate20.0 SEER2 · 8.5 HSPF2
- AUX AH09MHA2DI-20US · cold climate20.0 SEER2 · 9.2 HSPF2
- AUX AJAN09HP115V1CO · cold climate20.0 SEER2 · 8.5 HSPF2
- PolarWave EZ-09Z-HP11520.0 SEER2 · 9.4 HSPF2
See all 395 9,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of January 14, 2026. How we use the data.