Friedrich FWP15AZ36AJ2N

Below average cooling and heating efficiency for a 3-ton central heat pump, but not rated for cold climates.

Ranks #278 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,141 a year to run in a mixed climate like Atlanta.

SEER2
15.2 Cooling efficiency over a season
Below average · beats 6%
HSPF2
8.1 Heating efficiency over a season
Below average · beats 20%
EER2
11.7 Cooling efficiency on a 95°F day
Average · beats 43%
Heat at 5°F
19,900 BTU/h56% of its 47°F output
Very good · beats 88%

A good fit if…

  • You want a choice of indoor units - 38 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications3 ton, R-410A
General
BrandFriedrich
Outdoor unit modelFWP15AZ36AJ2N
SeriesF-SERIES PLUS
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceFebruary 24, 2023
Last certifiedJune 3, 2026
Cooling
SEER2Seasonal efficiency, higher is better15.2 (range 15.2)
EER2Efficiency at 95°F outdoors11.7
Cooling capacity34,000-34,200 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.1
Capacity at 47°F34,000-34,200 BTU/h
Capacity at 17°F22,400-24,800 BTU/h
Capacity at 5°F17,500-19,900 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00-2.30
ENERGY STAR cold climateNo
Heating output as it gets colder56% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FRH2VZ3621STANN at the standard test temperatures, in BTU/h:

Certified matchups38 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
FRH2VZ3621STANN-15.211.78.119,300213382071
FRH2VZ3617STANN-15.211.78.119,400213382072
TCFZ3621STANMFR802V1004A17UH15.211.78.119,800213841480
TCFZ3621STANMFR802V1005A21UH15.211.78.119,800213841518
TCFZ3621STANMFR801V0755A21UH15.211.78.119,700213841490
TCFZ3621STANMFR802V0755A21UH15.211.78.119,700213841499
TCFZ3621STANMFR801V0754A17UH15.211.78.119,700213841493
TCFZ3621STANMFR802V1005A21UHN15.211.78.119,800213841501
TCFZ3621STANMFR802V0754A17UH15.211.78.119,700213841457
TCFZ3621STANMFR801V1005A21UHU15.211.78.119,800213841503
TCFZ3617STANMFR801V1004A17UH15.211.78.119,900213841508
TCFZ3621STANMFR802V0755A21DZ15.211.78.119,700213841513
TCFZ3621STANMFR801V1005A21UHS15.211.78.119,700213841512
TCFZ3621STANMFR801V0755A21DZ15.211.78.119,700213841516
TCFZ3617STANMFR802V0754A17UH15.211.78.119,700213841451
TCFZ3617STANMFR801V0754A17UH15.211.78.119,700213841458
TCFZ3621STANMFR801V1005A21DZ15.211.78.119,700213841460
TCFZ3621STANMFR801V1005A21UHN15.211.78.119,700213841452
TCFZ3617STANMFR802V1004A17UH15.211.78.119,800213841468
RCFZ3621STANMFR802V1005A21UH15.211.78.119,800214328095
RCFZ3621STANMFR802V0755A21UH15.211.78.119,700214328082
RCFZ3617STANMFR802V0754A17UH15.211.78.119,700214328062
RCFZ3621STANMFR802V1004A17UH15.211.78.119,800214328074
RCFZ3621STANMFR801V1005A21UHN15.211.78.119,700214328063
RCFZ3621STANMFR801V0755A21DZ15.211.78.119,700214328093
RCFZ3621STANMFR802V1005A21UHN15.211.78.119,800214328084
RCFZ3621STANMFR801V1005A21UHS15.211.78.119,700214328091
RCFZ3621STANMFR801V1005A21DZ15.211.78.119,700214328067
RCFZ3617STANMFR801V1004A17UH15.211.78.119,900214328087
RCFZ3621STANMFR802V0755A21DZ15.211.78.119,700214328092
RCFZ3617STANMFR801V0754A17UH15.211.78.119,700214328066
RCFZ3621STANMFR801V0754A17UH15.211.78.119,700214328079
RCFZ3621STANMFR801V0755A21UH15.211.78.119,700214328077
RCFZ3617STANMFR802V1004A17UH15.211.78.119,800214328069
RCFZ3621STANMFR801V1005A21UHU15.211.78.119,800214328086
RCFZ3621STANMFR802V0754A17UH15.211.78.119,700214328065
FRH2TZ3617STANN-15.211.77.819,400213087951
FRH3VZ3617STACN-15.211.77.817,500214664605
Yearly running cost in 10 large cities$1,055-$2,698

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Friedrich FWP15AZ36AJ2N?
The Friedrich FWP15AZ36AJ2N is rated at up to 15.2 SEER2 and 11.7 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
Is the Friedrich FWP15AZ36AJ2N good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3-ton model.
How much does the Friedrich FWP15AZ36AJ2N cost to run per year?
At its rated efficiency it costs about $1,055-$2,698 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,284 in Phoenix and $2,241 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Friedrich FWP15AZ36AJ2N?
ENERGY STAR lists 38 certified combinations for this outdoor unit. The highest-rated ones use FRH2VZ3621STANN, FRH2VZ3617STANN, TCFZ3621STANM.
What refrigerant does the Friedrich FWP15AZ36AJ2N use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,265/yrYou save $499/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Friedrich FWP15AZ36AJ2N
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,265
Current system, per year
$1,763
You save per year
$499
Payback
26.1 years
Net after 10 years
-$8,015

Cooling $792Heating $473Electricity used: 7,906 kWhSaved vs. a minimum-efficiency heat pump: $88

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 3, 2026. How we use the data.