HVAC Rated

24,000 BTU mini-split heat pump · J-7S

Fujitsu AOUK024SSAN7

Average cooling efficiency and very good heating efficiency for a 24,000 BTU mini-split heat pump, and certified for cold climates.

Ranks #172 of 430 24,000 BTU mini-splits for cooling efficiency, and costs about $623 a year to run in a mixed climate like Atlanta.

SEER2
22.2 Cooling efficiency over a season
Average · beats 52%
HSPF2
11.3 Heating efficiency over a season
Very good · beats 81%
EER2
15.7 Cooling efficiency on a 95°F day
Excellent · beats 94%
Heat at 5°F
26,200 BTU/h94% of its 47°F output
Excellent · beats 96%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 26,200 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 81% of mini-splits.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications24,000 BTU, R-32
General
BrandFujitsu
Outdoor unit modelAOUK024SSAN7
SeriesJ-7S
TypeMini-split heat pump
Nominal size24,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-32
Connected (smart) capableNo
On the market sinceDecember 10, 2024
Last certifiedApril 17, 2026
Cooling
SEER2Seasonal efficiency, higher is better22.2 (range 16.0-22.2)
EER2Efficiency at 95°F outdoors12.6-15.7
Cooling capacity24,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better9.2-11.3
Capacity at 47°F28,000 BTU/h
Capacity at 17°F17,400-17,800 BTU/h
Capacity at 5°F23,000-26,200 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.06-2.44
ENERGY STAR cold climateYes
Heating output as it gets colder94% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:

Certified matchups3 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
- FUJITSU · cold climate22.215.711.326,200216372779
- FUJITSU · cold climate19.114.210.324,600216372785
- FUJITSU · cold climate16.012.69.223,000216372780
Yearly running cost in 10 large cities$511-$1,526

At each state's average electricity price and the city's typical heating and cooling hours.

Questions4
What is the SEER2 rating of the Fujitsu AOUK024SSAN7?
The Fujitsu AOUK024SSAN7 is rated at up to 22.2 SEER2 and 15.7 EER2 for cooling and up to 11.3 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 3 certified matchups SEER2 ranges from 16.0-22.2.
Is the Fujitsu AOUK024SSAN7 good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 26,200 BTU/h at 5°F with a COP of 2.44, so it is still 2.4 times as efficient as electric resistance heat at that temperature.
How much does the Fujitsu AOUK024SSAN7 cost to run per year?
At its rated efficiency it costs about $511-$1,526 a year in electricity in large U.S. cities, depending on climate and local rates - for example $652 in Phoenix and $1,292 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
What refrigerant does the Fujitsu AOUK024SSAN7 use?
It uses R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $658/yrYou save $645/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Fujitsu AOUK024SSAN7
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$658
Current system, per year
$1,303
You save per year
$645
Payback
14.0 years
Net after 10 years
-$2,551

Cooling $381Heating $278Electricity used: 4,113 kWhSaved vs. a minimum-efficiency heat pump: $351

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 24,000 BTU models

See all 430 24,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of April 17, 2026. How we use the data.