HVAC Rated

9,000 BTU mini-split heat pump · Endure

GE Appliances ASH109URDSE

Excellent cooling and heating efficiency for a 9,000 BTU mini-split heat pump, but not rated for cold climates.

Ranks #14 of 395 9,000 BTU mini-splits for cooling efficiency, and costs about $177 a year to run in a mixed climate like Atlanta.

SEER2
30.0 Cooling efficiency over a season
Excellent · beats 99%
HSPF2
14.0 Heating efficiency over a season
Excellent · beats 98%
EER2
16.0 Cooling efficiency on a 95°F day
Excellent · beats 96%
Heat at 5°F
5,900 BTU/h59% of its 47°F output
Below average · beats 9%

A good fit if…

  • You want low cooling bills - its SEER2 beats 99% of mini-splits.
  • It will heat most of the year - its HSPF2 beats 98% of mini-splits.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications9,000 BTU, R-410A
General
BrandGE Appliances
Also sold asHaier
Outdoor unit modelASH109URDSE
SeriesEndure
TypeMini-split heat pump
Nominal size9,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceApril 15, 2021
Last certifiedSeptember 1, 2026
Cooling
SEER2Seasonal efficiency, higher is better30.0 (range 30.0)
EER2Efficiency at 95°F outdoors16.0
Cooling capacity9,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better14.0
Capacity at 47°F10,000 BTU/h
Capacity at 17°F6,500 BTU/h
Capacity at 5°F5,900 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.80
ENERGY STAR cold climateNo
Heating output as it gets colder59% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with ASYW09URDWD at the standard test temperatures, in BTU/h:

Certified matchups1 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
ASYW09URDWD30.016.014.05,900206842132
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the GE Appliances ASH109URDSE: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$142-$437

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the GE Appliances ASH109URDSE?
The GE Appliances ASH109URDSE is rated at up to 30.0 SEER2 and 16.0 EER2 for cooling and up to 14.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
Is the GE Appliances ASH109URDSE good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 9,000 BTU model.
How much does the GE Appliances ASH109URDSE cost to run per year?
At its rated efficiency it costs about $142-$437 a year in electricity in large U.S. cities, depending on climate and local rates - for example $183 in Phoenix and $371 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the GE Appliances ASH109URDSE the same as the Haier 1U09EH2VHE?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the GE Appliances ASH109URDSE?
ENERGY STAR lists 1 certified combination for this outdoor unit. The highest-rated one uses ASYW09URDWD.
What refrigerant does the GE Appliances ASH109URDSE use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $186/yrYou save $295/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump GE Appliances ASH109URDSE
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$186
Current system, per year
$480
You save per year
$295
Payback
11.9 years
Net after 10 years
-$552

Cooling $106Heating $80Electricity used: 1,160 kWhSaved vs. a minimum-efficiency heat pump: $185

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 9,000 BTU models

See all 395 9,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 1, 2026. How we use the data.