12,000 BTU mini-split heat pump · Clivia
GREE GWH12AUCXD-D6DNA1B/O
Very good cooling efficiency and below average heating efficiency for a 12,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #151 of 394 12,000 BTU mini-splits for cooling efficiency, and costs about $305 a year to run in a mixed climate like Atlanta.
- SEER2
- 24.5 Cooling efficiency over a seasonVery good · beats 79%
- HSPF2
- 9.5 Heating efficiency over a seasonBelow average · beats 24%
- EER2
- 13.0 Cooling efficiency on a 95°F dayAverage · beats 62%
- Heat at 5°F
- 11,000 BTU/h92% of its 47°F outputBelow average · beats 34%
A good fit if…
- You want low cooling bills - its SEER2 beats 79% of mini-splits.
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 11,000 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- You mainly need heat - its HSPF2 is below average for mini-splits.
Details
Specifications
| General | |
|---|---|
| Brand | GREE |
| Outdoor unit model | GWH12AUCXD-D6DNA1B/O |
| Series | Clivia |
| Type | Mini-split heat pump |
| Nominal size | 12,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-32 |
| Connected (smart) capable | No |
| On the market since | January 12, 2024 |
| Last certified | August 11, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 24.5 (range 23.0-24.5) |
| EER2Efficiency at 95°F outdoors | 13.0 |
| Cooling capacity | 12,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.0-9.5 |
| Capacity at 47°F | 12,000 BTU/h |
| Capacity at 17°F | 7,700-12,000 BTU/h |
| Capacity at 5°F | 10,000-11,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.90-1.95 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with GWH12AUCXD-D6DN***/I at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| GWH12AUCXD-D6DN***/I · cold climate | 24.5 | 13.0 | 9.5 | 11,000 | 213927625 |
| GWH12AGCXD-D6DN***/I · cold climate | 24.5 | 13.0 | 9.5 | 11,000 | 214796624 |
| GWH12AGCXD-D3DN***/I · cold climate | 24.5 | 13.0 | 9.5 | 11,000 | 217548380 |
| GEH(12)AA-D3DN***/I · cold climate | 23.0 | 13.0 | 9.0 | 10,000 | 217178846 |
Yearly running cost in 10 large cities
- Phoenix, AZ$306/yr
- Miami, FL$232/yr
- Houston, TX$275/yr
- Atlanta, GA$305/yr
- Los Angeles, CA$303/yr
- New York, NY$763/yr
- Chicago, IL$626/yr
- Denver, CO$525/yr
- Seattle, WA$327/yr
- Minneapolis, MN$652/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the GREE GWH12AUCXD-D6DNA1B/O?
- The GREE GWH12AUCXD-D6DNA1B/O is rated at up to 24.5 SEER2 and 13.0 EER2 for cooling and up to 9.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 4 certified matchups SEER2 ranges from 23.0-24.5.
- Is the GREE GWH12AUCXD-D6DNA1B/O good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 11,000 BTU/h at 5°F with a COP of 1.95, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
- How much does the GREE GWH12AUCXD-D6DNA1B/O cost to run per year?
- At its rated efficiency it costs about $232-$763 a year in electricity in large U.S. cities, depending on climate and local rates - for example $306 in Phoenix and $652 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the GREE GWH12AUCXD-D6DNA1B/O?
- ENERGY STAR lists 4 certified combinations for this outdoor unit. The highest-rated ones use GWH12AUCXD-D6DN***/I, GWH12AGCXD-D6DN***/I, GWH12AGCXD-D3DN***/I.
- What refrigerant does the GREE GWH12AUCXD-D6DNA1B/O use?
- It uses R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 12,000 BTU models
- Kinghome KW12XQ25S1DO · cold climate24.5 SEER2 · 9.5 HSPF2
- Ouellet OCVX-H12A-O · cold climate24.5 SEER2 · 9.5 HSPF2
- Blueridge BXS4Z12UC0 · cold climate24.5 SEER2 · 9.5 HSPF2
- TOSOT SU-AORAKI12-230/O · cold climate24.5 SEER2 · 9.5 HSPF2
- MRCOOL O-ES-12-HP-C-230B24.6 SEER2 · 10.7 HSPF2
- TOSOT TAVCI7H1R12 · cold climate24.5 SEER2 · 9.5 HSPF2
- MDV MOX230-12HFN1-MV5W-L · cold climate24.6 SEER2 · 10.7 HSPF2
- TOSOT TAVCI7H4R12 · cold climate24.5 SEER2 · 9.5 HSPF2
See all 394 12,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of August 11, 2026. How we use the data.