4-ton central heat pump · G Series
GREE WLUD48W2/NHG-D(U)
Excellent cooling efficiency and very good heating efficiency for a 4-ton central heat pump, but not rated for cold climates.
Ranks #13 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,308 a year to run in a mixed climate like Atlanta.
- SEER2
- 20.0 Cooling efficiency over a seasonExcellent · beats 94%
- HSPF2
- 9.5 Heating efficiency over a seasonVery good · beats 70%
- EER2
- 11.7 Cooling efficiency on a 95°F dayAverage · beats 43%
- Heat at 5°F
- 36,000 BTU/h75% of its 47°F outputVery good · beats 71%
A good fit if…
- You want low cooling bills - its SEER2 beats 94% of central heat pumps.
- It will heat most of the year - its HSPF2 beats 70% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
Details
Specifications
| General | |
|---|---|
| Brand | GREE |
| Also sold as | Kinghome |
| Outdoor unit model | WLUD48W2/NHG-D(U) |
| Series | G Series |
| Type | Central heat pump |
| Nominal size | 4 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-32 |
| Connected (smart) capable | No |
| On the market since | December 18, 2024 |
| Last certified | July 17, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 20.0 (range 20.0) |
| EER2Efficiency at 95°F outdoors | 11.7 |
| Cooling capacity | 48,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.5 |
| Capacity at 47°F | 48,000 BTU/h |
| Capacity at 17°F | 38,500 BTU/h |
| Capacity at 5°F | 36,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.18 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with WLUD48AH2/G-D(U) at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| WLUD48AH2/G-D(U) | 20.0 | 11.7 | 9.5 | 36,000 | 218426819 |
Same unit, other model numbers
These model numbers have exactly the same certified ratings and matchups as the GREE WLUD48W2/NHG-D(U): the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.
- Kinghome KD48UXO
Yearly running cost in 10 large cities
- Phoenix, AZ$1,412/yr
- Miami, FL$1,130/yr
- Houston, TX$1,266/yr
- Atlanta, GA$1,308/yr
- Los Angeles, CA$1,278/yr
- New York, NY$3,158/yr
- Chicago, IL$2,570/yr
- Denver, CO$2,142/yr
- Seattle, WA$1,320/yr
- Minneapolis, MN$2,653/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the GREE WLUD48W2/NHG-D(U)?
- The GREE WLUD48W2/NHG-D(U) is rated at up to 20.0 SEER2 and 11.7 EER2 for cooling and up to 9.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
- Is the GREE WLUD48W2/NHG-D(U) good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 4-ton model.
- How much does the GREE WLUD48W2/NHG-D(U) cost to run per year?
- At its rated efficiency it costs about $1,130-$3,158 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,412 in Phoenix and $2,653 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Is the GREE WLUD48W2/NHG-D(U) the same as the Kinghome KD48UXO?
- Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
- Which indoor units work with the GREE WLUD48W2/NHG-D(U)?
- ENERGY STAR lists 1 certified combination for this outdoor unit. The highest-rated one uses WLUD48AH2/G-D(U).
- What refrigerant does the GREE WLUD48W2/NHG-D(U) use?
- It uses R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 4 ton models
- TOSOT TU60W-GDU20.0 SEER2 · 9.5 HSPF2
- Midea MDV-V48WMN10T · cold climate20.0 SEER2 · 10.1 HSPF2
- Trane 4TWV0X48A120.0 SEER2 · 8.7 HSPF2
- SAMYOU VUH48-VA6BA(O) · cold climate20.0 SEER2 · 11.0 HSPF2
- SAMYOU VUH60-VA6BA(0) · cold climate19.6 SEER2 · 10.8 HSPF2
- Trane/American Standard 5HCL9048A1000A · cold climate20.2 SEER2 · 8.7 HSPF2
- Bosch BOHA-60MTB-M18S · cold climate19.5 SEER2 · 10.1 HSPF2
- Armstrong Air A7CP21V60P-**A · cold climate20.5 SEER2 · 9.0 HSPF2
See all 319 4 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 17, 2026. How we use the data.