2-ton central heat pump · Connect 2026
Haier QS15H24HA5
Average cooling and heating efficiency for a 2-ton central heat pump, and certified for cold climates.
Ranks #196 of 331 2 ton central heat pumps for cooling efficiency, and costs about $702 a year to run in a mixed climate like Atlanta.
- SEER2
- 17.5 Cooling efficiency over a seasonAverage · beats 58%
- HSPF2
- 8.9 Heating efficiency over a seasonAverage · beats 50%
- EER2
- 9.3 Cooling efficiency on a 95°F dayBelow average · beats 4%
- Heat at 5°F
- 18,900 BTU/h75% of its 47°F outputBelow average · beats 20%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 18,900 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
- You want a choice of indoor units - 113 certified pairings.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | Haier |
| Outdoor unit model | QS15H24HA5 |
| Series | Connect 2026 |
| Type | Central heat pump |
| Nominal size | 2 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | February 11, 2026 |
| Last certified | July 17, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 17.5 (range 15.2-17.5) |
| EER2Efficiency at 95°F outdoors | 9.0-9.7 |
| Cooling capacity | 22,600-24,400 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.1-8.9 |
| Capacity at 47°F | 23,400-25,000 BTU/h |
| Capacity at 17°F | 17,900-18,900 BTU/h |
| Capacity at 5°F | 17,900-18,900 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.80-1.90 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with NAM24E1TA5 at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 113 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| NAM24E1TA5 · cold climate | - | 17.5 | 9.3 | 8.9 | 18,700 | 218382708 |
| NCHC30BT5****+TDR · cold climate | NF97U030T2BRF*** | 16.9 | 9.5 | 8.2 | 18,200 | 218685741 |
| NAM30V3TA5 · cold climate | - | 16.7 | 9.5 | 8.9 | 18,500 | 218382714 |
| NCUC36BT5****+TDR · cold climate | NF96U045V3BF*** | 16.6 | 9.6 | 8.2 | 18,100 | 218685711 |
| NCUC36BT5****+TDR · cold climate | NF80U090V3BF*** | 16.6 | 9.7 | 8.2 | 18,000 | 218685697 |
| NCUC36BT5****+TDR · cold climate | NF97X040V3B*** | 16.6 | 9.6 | 8.2 | 18,100 | 218685367 |
| NCUC36AT5****+TDR · cold climate | NF80U045T3A*** | 16.6 | 9.7 | 8.2 | 18,000 | 218685360 |
| NCHC30AT5****+TDR · cold climate | NF80U045T3A*** | 16.5 | 9.7 | 8.4 | 17,900 | 218685387 |
| NCUC36BT5****+TDR · cold climate | NF96U070V3BF*** | 16.5 | 9.6 | 8.2 | 18,100 | 218685712 |
| NCUC36AT5****+TDR · cold climate | NF80U030V3AF*** | 16.5 | 9.7 | 8.2 | 18,000 | 218685694 |
| NCHC30BT5****+TDR · cold climate | NF96U070V3BF*** | 16.5 | 9.6 | 8.1 | 18,200 | 218685759 |
| NCHC30BT5****+TDR · cold climate | NF80U070V4BF*** | 16.5 | 9.7 | 8.1 | 18,100 | 218685752 |
| NCHC30AT5****+TDR · cold climate | NF80U030V3AF*** | 16.4 | 9.7 | 8.4 | 17,900 | 218685738 |
| NCHC30BT5****+TDR · cold climate | NF96U045V3BF*** | 16.4 | 9.6 | 8.2 | 18,200 | 218685758 |
| NCHC24BT5****+TDR · cold climate | NF80U090V3BF*** | 16.4 | 9.6 | 8.2 | 18,100 | 218685735 |
| NCHC24BT5****+TDR · cold climate | NF96U070V3BF*** | 16.4 | 9.5 | 8.2 | 18,200 | 218685734 |
| NCHC24BT5****+TDR · cold climate | NF96U045V3BF*** | 16.4 | 9.6 | 8.2 | 18,200 | 218685733 |
| NCHC30BT5****+TDR · cold climate | NF97X040V3B*** | 16.4 | 9.5 | 8.2 | 18,200 | 218685400 |
| NCHC24BT5****+TDR · cold climate | NF97X040V3B*** | 16.4 | 9.5 | 8.2 | 18,200 | 218685382 |
| NCUC36BT5****+TDR · cold climate | NF98U070M3B*** | 16.4 | 9.7 | 8.2 | 18,000 | 218685369 |
| NCHC30BT5****+TDR · cold climate | NF80U090V3BF*** | 16.4 | 9.7 | 8.1 | 18,100 | 218685760 |
| NAS30E1TB5 · cold climate | - | 16.3 | 9.2 | 8.9 | 18,600 | 218382707 |
| NAS24E1TB5 · cold climate | - | 16.3 | 9.2 | 8.9 | 18,600 | 218382705 |
| NCHC30AT5****+TDR · cold climate | NF80U070V3AF*** | 16.3 | 9.6 | 8.4 | 17,900 | 218685740 |
| NCUC36BT5****+TDR · cold climate | NF97U070V3BF*** | 16.3 | 9.6 | 8.2 | 18,100 | 218685706 |
| NCUC36AT5****+TDR · cold climate | NF80U070V3AF*** | 16.3 | 9.6 | 8.2 | 18,100 | 218685696 |
| NCUC36AT5****+TDR · cold climate | NF80X060S3A*** | 16.3 | 9.4 | 8.2 | 18,200 | 218685358 |
| NCUC36AT5****+TDR · cold climate | NF80X040S3A*** | 16.3 | 9.4 | 8.2 | 18,200 | 218685357 |
| NCHC30BT5****+TDR · cold climate | NF80U090V4BF*** | 16.3 | 9.4 | 8.1 | 18,300 | 218685753 |
| NCHC30BT5****+TDR · cold climate | NF97U070V3BF*** | 16.3 | 9.6 | 8.1 | 18,100 | 218685750 |
| NCUC24BT5****+TDR · cold climate | NF80U070V4BF*** | 16.3 | 9.5 | 8.1 | 18,200 | 218685661 |
| NAM30V2TA5 · cold climate | - | 16.2 | 9.3 | 8.9 | 18,500 | 218382717 |
| NAM30V1TA5 · cold climate | - | 16.2 | 9.1 | 8.5 | 18,900 | 218382711 |
| NAM30E1TA5 · cold climate | - | 16.2 | 9.4 | 8.5 | 18,700 | 218382710 |
| NCHC30AT5****+TDR · cold climate | NF80U045S3A*** | 16.2 | 9.4 | 8.4 | 18,100 | 218685389 |
| NCUC36BT5****+TDR · cold climate | NF97U045V3BF*** | 16.2 | 9.5 | 8.2 | 18,100 | 218685705 |
| NCUC36BT5****+TDR · cold climate | NF80U070V3BF*** | 16.2 | 9.7 | 8.2 | 18,000 | 218685699 |
| NCUC36AT5****+TDR · cold climate | NF80U045V3AF*** | 16.2 | 9.6 | 8.2 | 18,100 | 218685695 |
| NCUC36BT5****+TDR · cold climate | NF97X060V3B*** | 16.2 | 9.5 | 8.2 | 18,100 | 218685368 |
| NCHC30BT5****+TDR · cold climate | NF96U030T3BF*** | 16.2 | 9.3 | 8.1 | 18,400 | 218685757 |
| NCHC30BT5****+TDR · cold climate | NF93U070T3BF*** | 16.2 | 9.5 | 8.1 | 18,200 | 218685756 |
| NCHC24BT5****+TDR · cold climate | NF97U070V3BF*** | 16.2 | 9.6 | 8.1 | 18,200 | 218685727 |
| NCUC36BT5****+TDR · cold climate | NF93U070T3BF*** | 16.2 | 9.5 | 8.1 | 18,200 | 218685710 |
| NCHC30BT5****+TDR · cold climate | NF98U070M3B*** | 16.2 | 9.6 | 8.1 | 18,100 | 218685401 |
| NCHC24BT5****+TDR · cold climate | NF98U070M3B*** | 16.2 | 9.6 | 8.1 | 18,200 | 218685384 |
| NCHC30AT5****+TDR · cold climate | NF80L045S3A*** | 16.1 | 9.7 | 8.4 | 17,900 | 218685391 |
| NCHC30AT5****+TDR · cold climate | NF80X060V3A*** | 16.1 | 9.6 | 8.4 | 18,000 | 218685386 |
| NCUC36BT5****+TDR · cold climate | NF80U090T3BF*** | 16.1 | 9.7 | 8.2 | 18,000 | 218685698 |
| NCUC24BT5****+TDR · cold climate | NF80U090T3BF*** | 16.1 | 9.2 | 8.2 | 18,400 | 218685655 |
| NCHC30BT5****+TDR · cold climate | NF96L030T3BF*** | 16.1 | 9.5 | 8.1 | 18,200 | 218685742 |
| NCHC24BT5****+TDR · cold climate | NF93U070T3BF*** | 16.1 | 9.4 | 8.1 | 18,300 | 218685731 |
| NCHC24AT5****+TDR · cold climate | NF80U030V3AF*** | 16.1 | 9.5 | 8.1 | 18,200 | 218685715 |
| NCUC36BT5****+TDR · cold climate | NF93U030T3BF*** | 16.1 | 9.3 | 8.1 | 18,300 | 218685708 |
| NCUC36BT5****+TDR · cold climate | NF96L030T3BF*** | 16.1 | 9.5 | 8.1 | 18,100 | 218685702 |
| NCUC24BT5****+TDR · cold climate | NF80U090V3BF*** | 16.1 | 9.5 | 8.1 | 18,200 | 218685669 |
| NCUC24BT5****+TDR · cold climate | NF96U045V3BF*** | 16.1 | 9.4 | 8.1 | 18,300 | 218685667 |
| NCUC36AT5****+TDR · cold climate | NF80X060V3A*** | 16.1 | 9.6 | 8.1 | 18,100 | 218685356 |
| NAM24V1TA5 · cold climate | - | 16.0 | 9.0 | 8.5 | 18,000 | 218078929 |
| NCHC30AT5****+TDR · cold climate | NF80U045V3AF*** | 16.0 | 9.6 | 8.4 | 17,900 | 218685739 |
| NCHC30AT5****+TDR · cold climate | NF80L070T3AF*** | 16.0 | 9.7 | 8.4 | 17,900 | 218685737 |
Yearly running cost in 10 large cities
- Phoenix, AZ$774/yr
- Miami, FL$628/yr
- Houston, TX$694/yr
- Atlanta, GA$702/yr
- Los Angeles, CA$683/yr
- New York, NY$1,676/yr
- Chicago, IL$1,361/yr
- Denver, CO$1,131/yr
- Seattle, WA$695/yr
- Minneapolis, MN$1,400/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Haier QS15H24HA5?
- The Haier QS15H24HA5 is rated at up to 17.5 SEER2 and 9.3 EER2 for cooling and up to 8.9 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 113 certified matchups SEER2 ranges from 15.2-17.5.
- Is the Haier QS15H24HA5 good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 18,900 BTU/h at 5°F with a COP of 1.90, so it is still 1.9 times as efficient as electric resistance heat at that temperature.
- How much does the Haier QS15H24HA5 cost to run per year?
- At its rated efficiency it costs about $628-$1,676 a year in electricity in large U.S. cities, depending on climate and local rates - for example $774 in Phoenix and $1,400 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Haier QS15H24HA5?
- ENERGY STAR lists 113 certified combinations for this outdoor unit. The highest-rated ones use NAM24E1TA5, NCHC30BT5****+TDR, NAM30V3TA5.
- What refrigerant does the Haier QS15H24HA5 use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 2 ton models
- Heil D5CUHAH24AAK+TIC2025-0016 · cold climate17.5 SEER2 · 9.5 HSPF2
- Samsung AC024FCUPCG · cold climate17.5 SEER2 · 8.5 HSPF2
- Carrier 37MUHAQ24AA3+TIC2025-0016 · cold climate17.5 SEER2 · 9.5 HSPF2
- GREE WLUD30W2/NHG-D(U)17.5 SEER2 · 8.3 HSPF2
- Multi MFG HHS-25HD-B · cold climate17.5 SEER2 · 10.0 HSPF2
- Lennox ML16KP2-024-230A17.5 SEER2 · 8.2 HSPF2
- Breeze33 BZ33-INV24OUT2-J · cold climate17.5 SEER2 · 10.5 HSPF2
- Elios ESHEA24R2AN1 · cold climate17.4 SEER2 · 10.4 HSPF2
See all 331 2 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 17, 2026. How we use the data.