HVAC Rated

4-ton central heat pump · MAINLINE 16 SEER2 HP

Heil B5H6S48*K*AAA

Below average cooling and heating efficiency for a 4-ton central heat pump, but not rated for cold climates.

Ranks #290 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,610 a year to run in a mixed climate like Atlanta.

SEER2
15.5 Cooling efficiency over a season
Below average · beats 15%
HSPF2
7.8 Heating efficiency over a season
Below average · beats 5%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
24,400 BTU/h50% of its 47°F output
Very good · beats 88%

A good fit if…

  • You want a choice of indoor units - 40 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications4 ton, R-454B
General
BrandHeil
Also sold asTempstar, Kenmore, Arcoaire, Airquest, Keeprite, Day & Night, Comfortmaker
Outdoor unit modelB5H6S48*K*AAA
SeriesMAINLINE 16 SEER2 HP
TypeCentral heat pump
Nominal size4 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJanuary 1, 2024
Last certifiedJune 29, 2026
Cooling
SEER2Seasonal efficiency, higher is better15.5 (range 15.2-15.5)
EER2Efficiency at 95°F outdoors12.0-12.5
Cooling capacity46,500-48,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8
Capacity at 47°F46,500-48,500 BTU/h
Capacity at 17°F30,000-30,600 BTU/h
Capacity at 5°F23,600-24,400 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.26-2.30
ENERGY STAR cold climateNo
Heating output as it gets colder50% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FTMA5B60L0D at the standard test temperatures, in BTU/h:

Certified matchups40 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
FTMA5B60L0D15.512.07.823,600218188899
FTMA5B60L0D15.512.07.823,600218209694
FTMA5B60L0D15.512.07.823,600218211125
FTMA5B60L0D15.512.07.823,600218211977
FTMA5B60L0D15.512.07.823,600218211976
FTMA5B60L0D15.512.07.823,600218213605
FTMA5B60L0D15.512.07.823,600218213604
FTMA5B60L0D15.512.07.823,600218213603
FEVA0060**+NAVA56001CK15.212.07.824,400218188942
FEVB0060**+NAVA56001CK15.212.07.824,400218188927
FHMA5*60L*D15.212.57.824,400218188898
FEVA0060**+NAVA56001CK15.212.07.824,400218189170
F5MA5*60L*D15.212.57.824,400218189168
FEVA0060**+NAVA56001CK15.212.07.824,400218198564
F5MA5*60L*D15.212.57.824,400218198562
FEVA0060**+NAVA56001CK15.212.07.824,400218202364
FEVA0060**+NAVA56001CK15.212.07.824,400218202363
F5MA5*60L*D15.212.57.824,400218202351
F5MA5*60L*D15.212.57.824,400218202350
F5MA5*60L*D15.212.57.824,400218202349
FEVB0060**+NAVA56001CK15.212.07.824,400218209722
FHMA5*60L*D15.212.57.824,400218209693
FEVA0060**+NAVA56001CK15.212.07.824,400218209022
FEVA0060**+NAVA56001CK15.212.07.824,400218209021
FEVA0060**+NAVA56001CK15.212.07.824,400218209020
F5MA5*60L*D15.212.57.824,400218209016
F5MA5*60L*D15.212.57.824,400218209015
F5MA5*60L*D15.212.57.824,400218209014
FEVB0060**+NAVA56001CK15.212.07.824,400218211153
FHMA5*60L*D15.212.57.824,400218211124
FHMA5*60L*D15.212.57.824,400218211975
FHMA5*60L*D15.212.57.824,400218211974
FEVB0060**+NAVA56001CK15.212.07.824,400218212033
FEVB0060**+NAVA56001CK15.212.07.824,400218212032
FEVB0060**+NAVA56001CK15.212.07.824,400218213687
FEVB0060**+NAVA56001CK15.212.07.824,400218213686
FHMA5*60L*D15.212.57.824,400218213602
FHMA5*60L*D15.212.57.824,400218213601
FHMA5*60L*D15.212.57.824,400218213600
FEVB0060**+NAVA56001CK15.212.07.824,400218213599
Yearly running cost in 10 large cities$1,440-$3,847

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Heil B5H6S48*K*AAA?
The Heil B5H6S48*K*AAA is rated at up to 15.5 SEER2 and 12.0 EER2 for cooling and up to 7.8 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 40 certified matchups SEER2 ranges from 15.2-15.5.
Is the Heil B5H6S48*K*AAA good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 4-ton model.
How much does the Heil B5H6S48*K*AAA cost to run per year?
At its rated efficiency it costs about $1,440-$3,847 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,775 in Phoenix and $3,214 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Heil B5H6S48*K*AAA?
ENERGY STAR lists 40 certified combinations for this outdoor unit. The highest-rated ones use FTMA5B60L0D, FEVA0060**+NAVA56001CK, FEVB0060**+NAVA56001CK.
What refrigerant does the Heil B5H6S48*K*AAA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,761/yrYou save $688/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Heil B5H6S48*K*AAA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,761
Current system, per year
$2,449
You save per year
$688
Payback
26.1 years
Net after 10 years
-$11,115

Cooling $1,079Heating $682Electricity used: 11,005 kWhSaved vs. a minimum-efficiency heat pump: $118

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 4 ton models

See all 319 4 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 29, 2026. How we use the data.