HVAC Rated

3.5-ton central heat pump · PERFORMANCE 16 SEER2 HP

Heil N5H5S42*K*AAA

Below average cooling and heating efficiency for a 3.5-ton central heat pump, but not rated for cold climates.

Ranks #108 of 138 3.5 ton central heat pumps for cooling efficiency, and costs about $1,398 a year to run in a mixed climate like Atlanta.

SEER2
15.5 Cooling efficiency over a season
Below average · beats 15%
HSPF2
7.8 Heating efficiency over a season
Below average · beats 5%
EER2
13.0 Cooling efficiency on a 95°F day
Very good · beats 89%
Heat at 5°F
19,900 BTU/h49% of its 47°F output
Very good · beats 83%

A good fit if…

  • You want a choice of indoor units - 43 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications3.5 ton, R-454B
General
BrandHeil
Also sold asAirquest, Arcoaire, Comfortmaker, Day & Night, Keeprite, MARATHERM, Smart Comfort, Tempstar, Kenmore, ACIQ
Outdoor unit modelN5H5S42*K*AAA
SeriesPERFORMANCE 16 SEER2 HP
TypeCentral heat pump
Nominal size3.5 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJanuary 1, 2024
Last certifiedJune 29, 2026
Cooling
SEER2Seasonal efficiency, higher is better15.5 (range 15.2-15.5)
EER2Efficiency at 95°F outdoors11.7-13.0
Cooling capacity41,500-43,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8
Capacity at 47°F39,000-40,500 BTU/h
Capacity at 17°F24,600-25,600 BTU/h
Capacity at 5°F19,000-19,900 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.20-2.26
ENERGY STAR cold climateNo
Heating output as it gets colder49% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FTMA5B60L0D at the standard test temperatures, in BTU/h:

Certified matchups43 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
FTMA5B60L0D15.513.07.819,000214180050
FTMA5B60L0D15.513.07.819,000214180052
FTMA5B60L0D15.513.07.819,000214180054
FTMA5B60L0D15.513.07.819,000214180056
FTMA5B60L0D15.513.07.819,000214180058
FTMA5B60L0D15.513.07.819,000214180060
FTMA5B60L0D15.513.07.819,000214180068
FTMA5B60L0D15.513.07.819,000214180062
FTMA5B60L0D15.513.07.819,000214180064
FTMA5B60L0D15.513.07.819,000214180066
FTMA5B60L0D15.513.07.819,000216629133
FHMA5*60L*D15.211.77.819,900214180008
FHMA5*60L*D15.211.77.819,900214180010
FHMA5*60L*D15.211.77.819,900214180012
FHMA5*60L*D15.211.77.819,900214180014
FHMA5*60L*D15.211.77.819,900214180016
FHMA5*60L*D15.211.77.819,900214180018
FHMA5*60L*D15.211.77.819,900214180020
FHMA5*60L*D15.211.77.819,900214180022
FHMA5*60L*D15.211.77.819,900214180024
FHMA5*60L*D15.211.77.819,900214180026
FEVB0060**+NAVA56001CK15.212.57.819,800214179586
FEVB0060**+NAVA56001CK15.212.57.819,800214277427
FEVB0060**+NAVA56001CK15.212.57.819,800214277430
FEVB0060**+NAVA56001CK15.212.57.819,800214277433
FEVB0060**+NAVA56001CK15.212.57.819,800214277436
FEVB0060**+NAVA56001CK15.212.57.819,800214277438
FEVB0060**+NAVA56001CK15.212.57.819,800214277443
FEVB0060**+NAVA56001CK15.212.57.819,800214277446
FEVB0060**+NAVA56001CK15.212.57.819,800214277448
FEVB0060**+NAVA56001CK15.212.57.819,800214277451
F5MA5*60L*D15.211.77.819,900216464107
F5MA5*60L*D15.211.77.819,900216464109
F5MA5*60L*D15.211.77.819,900216464111
F5MA5*60L*D15.211.77.819,900216464113
F5MA5*60L*D15.211.77.819,900216464115
F5MA5*60L*D15.211.77.819,900216464117
F5MA5*60L*D15.211.77.819,900216464119
F5MA5*60L*D15.211.77.819,900216464121
F5MA5*60L*D15.211.77.819,900216464123
F5MA5*60L*D15.211.77.819,900216464125
F5MA5*60L*D15.211.77.819,900216629131
FHMA5*60L*D15.211.77.819,900217738921
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the Heil N5H5S42*K*AAA: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$1,286-$3,312

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the Heil N5H5S42*K*AAA?
The Heil N5H5S42*K*AAA is rated at up to 15.5 SEER2 and 13.0 EER2 for cooling and up to 7.8 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 43 certified matchups SEER2 ranges from 15.2-15.5.
Is the Heil N5H5S42*K*AAA good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3.5-ton model.
How much does the Heil N5H5S42*K*AAA cost to run per year?
At its rated efficiency it costs about $1,286-$3,312 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,568 in Phoenix and $2,753 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the Heil N5H5S42*K*AAA the same as the Heil R5H5S42*K*AAA?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the Heil N5H5S42*K*AAA?
ENERGY STAR lists 43 certified combinations for this outdoor unit. The highest-rated ones use FTMA5B60L0D, FHMA5*60L*D, FEVB0060**+NAVA56001CK.
What refrigerant does the Heil N5H5S42*K*AAA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,547/yrYou save $612/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Heil N5H5S42*K*AAA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,547
Current system, per year
$2,159
You save per year
$612
Payback
26.1 years
Net after 10 years
-$9,880

Cooling $965Heating $582Electricity used: 9,667 kWhSaved vs. a minimum-efficiency heat pump: $104

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3.5 ton models

See all 138 3.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 29, 2026. How we use the data.