HVAC Rated

4-ton central heat pump · PERFORMANCE 16 SEER2 HP

Heil N5H5S48*K*AAA

Below average cooling and heating efficiency for a 4-ton central heat pump, but not rated for cold climates.

Ranks #291 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,610 a year to run in a mixed climate like Atlanta.

SEER2
15.5 Cooling efficiency over a season
Below average · beats 15%
HSPF2
7.8 Heating efficiency over a season
Below average · beats 5%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
24,400 BTU/h50% of its 47°F output
Very good · beats 88%

A good fit if…

  • You want a choice of indoor units - 53 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications4 ton, R-454B
General
BrandHeil
Also sold asAirquest, Arcoaire, Comfortmaker, Day & Night, Keeprite, MARATHERM, Smart Comfort, Tempstar, Kenmore, ACIQ
Outdoor unit modelN5H5S48*K*AAA
SeriesPERFORMANCE 16 SEER2 HP
TypeCentral heat pump
Nominal size4 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJanuary 1, 2024
Last certifiedJune 29, 2026
Cooling
SEER2Seasonal efficiency, higher is better15.5 (range 15.2-15.5)
EER2Efficiency at 95°F outdoors12.0-12.5
Cooling capacity46,500-48,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8
Capacity at 47°F46,500-48,500 BTU/h
Capacity at 17°F30,000-30,600 BTU/h
Capacity at 5°F23,600-24,400 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.26-2.30
ENERGY STAR cold climateNo
Heating output as it gets colder50% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FTMA5B60L0D at the standard test temperatures, in BTU/h:

Certified matchups53 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
FTMA5B60L0D15.512.07.823,600214180119
FTMA5B60L0D15.512.07.823,600214180121
FTMA5B60L0D15.512.07.823,600214180123
FTMA5B60L0D15.512.07.823,600214180125
FTMA5B60L0D15.512.07.823,600214180127
FTMA5B60L0D15.512.07.823,600214180129
FTMA5B60L0D15.512.07.823,600214180131
FTMA5B60L0D15.512.07.823,600214180133
FTMA5B60L0D15.512.07.823,600214180135
FTMA5B60L0D15.512.07.823,600214180137
FTMA5B60L0D15.512.07.823,600216629135
FEVB0060**+NAVA56001CK15.212.07.824,400214179624
FHMA5*60L*D15.212.57.824,400214179640
FHMA5*60L*D15.212.57.824,400214179642
FHMA5*60L*D15.212.57.824,400214179644
FHMA5*60L*D15.212.57.824,400214179646
FHMA5*60L*D15.212.57.824,400214179648
FHMA5*60L*D15.212.57.824,400214179650
FHMA5*60L*D15.212.57.824,400214179654
FHMA5*60L*D15.212.57.824,400214179652
FHMA5*60L*D15.212.57.824,400214179656
FHMA5*60L*D15.212.57.824,400214179658
FEVB0060**+NAVA56001CK15.212.07.824,400214277471
FEVB0060**+NAVA56001CK15.212.07.824,400214277474
FEVB0060**+NAVA56001CK15.212.07.824,400214277476
FEVB0060**+NAVA56001CK15.212.07.824,400214277479
FEVB0060**+NAVA56001CK15.212.07.824,400214277482
FEVB0060**+NAVA56001CK15.212.07.824,400214277486
FEVB0060**+NAVA56001CK15.212.07.824,400214277489
FEVB0060**+NAVA56001CK15.212.07.824,400214277492
FEVB0060**+NAVA56001CK15.212.07.824,400214277495
F5MA5*60L*D15.212.57.824,400216464185
F5MA5*60L*D15.212.57.824,400216464187
F5MA5*60L*D15.212.57.824,400216464195
F5MA5*60L*D15.212.57.824,400216464189
F5MA5*60L*D15.212.57.824,400216464191
F5MA5*60L*D15.212.57.824,400216464193
F5MA5*60L*D15.212.57.824,400216464197
F5MA5*60L*D15.212.57.824,400216464199
F5MA5*60L*D15.212.57.824,400216464201
F5MA5*60L*D15.212.57.824,400216464203
F5MA5*60L*D15.212.57.824,400216629117
FEVA0060**+NAVA56001CK15.212.07.824,400217051801
FEVA0060**+NAVA56001CK15.212.07.824,400217051803
FEVA0060**+NAVA56001CK15.212.07.824,400217051805
FEVA0060**+NAVA56001CK15.212.07.824,400217051807
FEVA0060**+NAVA56001CK15.212.07.824,400217051809
FEVA0060**+NAVA56001CK15.212.07.824,400217051811
FEVA0060**+NAVA56001CK15.212.07.824,400217051813
FEVA0060**+NAVA56001CK15.212.07.824,400217051815
FEVA0060**+NAVA56001CK15.212.07.824,400217051817
FEVA0060**+NAVA56001CK15.212.07.824,400217051819
FHMA5*60L*D15.212.57.824,400217738742
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the Heil N5H5S48*K*AAA: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$1,440-$3,847

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the Heil N5H5S48*K*AAA?
The Heil N5H5S48*K*AAA is rated at up to 15.5 SEER2 and 12.0 EER2 for cooling and up to 7.8 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 53 certified matchups SEER2 ranges from 15.2-15.5.
Is the Heil N5H5S48*K*AAA good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 4-ton model.
How much does the Heil N5H5S48*K*AAA cost to run per year?
At its rated efficiency it costs about $1,440-$3,847 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,775 in Phoenix and $3,214 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the Heil N5H5S48*K*AAA the same as the Heil R5H5S48*K*AAA?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the Heil N5H5S48*K*AAA?
ENERGY STAR lists 53 certified combinations for this outdoor unit. The highest-rated ones use FTMA5B60L0D, FEVB0060**+NAVA56001CK, FHMA5*60L*D.
What refrigerant does the Heil N5H5S48*K*AAA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,761/yrYou save $688/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Heil N5H5S48*K*AAA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,761
Current system, per year
$2,449
You save per year
$688
Payback
26.1 years
Net after 10 years
-$11,115

Cooling $1,079Heating $682Electricity used: 11,005 kWhSaved vs. a minimum-efficiency heat pump: $118

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 4 ton models

See all 319 4 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 29, 2026. How we use the data.