36,000 BTU mini-split heat pump · Hi MULTI Xtreme
Hisense AMW4-36U3TQA
Average cooling and heating efficiency for a 36,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #89 of 205 36,000 BTU mini-splits for cooling efficiency, and costs about $917 a year to run in a mixed climate like Atlanta.
- SEER2
- 22.0 Cooling efficiency over a seasonAverage · beats 48%
- HSPF2
- 10.0 Heating efficiency over a seasonAverage · beats 43%
- EER2
- 12.9 Cooling efficiency on a 95°F dayAverage · beats 56%
- Heat at 5°F
- 36,000 BTU/h100% of its 47°F outputBelow average · beats 32%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 36,000 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | Hisense |
| Also sold as | Innovair |
| Outdoor unit model | AMW4-36U3TQA |
| Series | Hi MULTI Xtreme |
| Type | Mini-split heat pump |
| Nominal size | 36,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | September 25, 2024 |
| Last certified | February 17, 2025 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 22.0 (range 19.0-22.0) |
| EER2Efficiency at 95°F outdoors | 12.9 |
| Cooling capacity | 36,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.0-10.0 |
| Capacity at 47°F | 36,000 BTU/h |
| Capacity at 17°F | 21,000-22,600 BTU/h |
| Capacity at 5°F | 32,400-36,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.83-1.92 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| - HISENSE · cold climate | 22.0 | 12.9 | 10.0 | 36,000 | 215735345 |
| - HISENSE · cold climate | 20.5 | 12.9 | 9.5 | 34,200 | 215735346 |
| - HISENSE · cold climate | 19.0 | 12.9 | 9.0 | 32,400 | 215735344 |
Same unit, other model numbers
Yearly running cost in 10 large cities
- Phoenix, AZ$975/yr
- Miami, FL$772/yr
- Houston, TX$874/yr
- Atlanta, GA$917/yr
- Los Angeles, CA$900/yr
- New York, NY$2,232/yr
- Chicago, IL$1,820/yr
- Denver, CO$1,519/yr
- Seattle, WA$938/yr
- Minneapolis, MN$1,883/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Hisense AMW4-36U3TQA?
- The Hisense AMW4-36U3TQA is rated at up to 22.0 SEER2 and 12.9 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 3 certified matchups SEER2 ranges from 19.0-22.0.
- Is the Hisense AMW4-36U3TQA good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 36,000 BTU/h at 5°F with a COP of 1.92, so it is still 1.9 times as efficient as electric resistance heat at that temperature.
- How much does the Hisense AMW4-36U3TQA cost to run per year?
- At its rated efficiency it costs about $772-$2,232 a year in electricity in large U.S. cities, depending on climate and local rates - for example $975 in Phoenix and $1,883 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Is the Hisense AMW4-36U3TQA the same as the Hisense AMO4-36U3T25U?
- Yes, as far as the certified ratings go. ENERGY STAR lists 3 model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
- What refrigerant does the Hisense AMW4-36U3TQA use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 36,000 BTU models
- Fujitsu AOUH36KWAS422.0 SEER2 · 10.0 HSPF2
- OLMO OS-RMS36-230VO · cold climate22.0 SEER2 · 10.0 HSPF2
- Fujitsu AOUH36KWAH4 · cold climate22.0 SEER2 · 10.0 HSPF2
- Rheem FPHMR36A3D · cold climate22.0 SEER2 · 10.0 HSPF2
- AUX ASPR42HPMULO · cold climate22.0 SEER2 · 10.0 HSPF2
- Mitsubishi Electric PUZ-A36NKA722.0 SEER2 · 9.3 HSPF2
- AUX AM5-H42/2DR3A · cold climate22.0 SEER2 · 10.0 HSPF2
- Mitsubishi Electric PUZ-A36NKA822.0 SEER2 · 9.3 HSPF2
See all 205 36,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of February 17, 2025. How we use the data.