42,000 BTU mini-split heat pump · airCore700
Hitachi PAS-48BUFASDQ1
Below average cooling efficiency and very good heating efficiency for a 42,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #42 of 61 42,000 BTU mini-splits for cooling efficiency, and costs about $1,152 a year to run in a mixed climate like Atlanta.
- SEER2
- 20.0 Cooling efficiency over a seasonBelow average · beats 18%
- HSPF2
- 10.8 Heating efficiency over a seasonVery good · beats 71%
- EER2
- 13.0 Cooling efficiency on a 95°F dayAverage · beats 62%
- Heat at 5°F
- 39,500 BTU/h84% of its 47°F outputAverage · beats 67%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 39,500 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 71% of mini-splits.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Cooling cost matters most - its SEER2 is below average for mini-splits.
Details
Specifications
| General | |
|---|---|
| Brand | Hitachi |
| Outdoor unit model | PAS-48BUFASDQ1 |
| Series | airCore700 |
| Type | Mini-split heat pump |
| Nominal size | 42,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-32 |
| Connected (smart) capable | No |
| On the market since | July 30, 2024 |
| Last certified | August 11, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 20.0 (range 17.0-20.0) |
| EER2Efficiency at 95°F outdoors | 11.5-13.0 |
| Cooling capacity | 42,000-45,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 10.0-10.8 |
| Capacity at 47°F | 44,000-48,000 BTU/h |
| Capacity at 17°F | 39,500-42,000 BTU/h |
| Capacity at 5°F | 36,600-39,500 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.00-2.10 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with PCI-B48UFA1DQ at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| PCI-B48UFA1DQ HITACHI · cold climate | 20.0 | 13.0 | 10.0 | 39,500 | 214723262 |
| PPIM-B48UFA1DQ HITACHI · cold climate | 19.0 | 12.5 | 10.0 | 39,000 | 213685842 |
| PPFC-B48UFA1DQ HITACHI · cold climate | 18.5 | 12.0 | 10.8 | 36,600 | 214779302 |
| JPE48C3XG2HS1A HITACHI · cold climate | 17.0 | 11.5 | 10.2 | 37,000 | 214911493 |
| JPE48C3XG2HS2 HITACHI · cold climate | 17.0 | 11.5 | 10.2 | 37,000 | 218700903 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,273/yr
- Miami, FL$1,034/yr
- Houston, TX$1,141/yr
- Atlanta, GA$1,152/yr
- Los Angeles, CA$1,121/yr
- New York, NY$2,752/yr
- Chicago, IL$2,234/yr
- Denver, CO$1,857/yr
- Seattle, WA$1,141/yr
- Minneapolis, MN$2,298/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Hitachi PAS-48BUFASDQ1?
- The Hitachi PAS-48BUFASDQ1 is rated at up to 20.0 SEER2 and 13.0 EER2 for cooling and up to 10.8 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 5 certified matchups SEER2 ranges from 17.0-20.0.
- Is the Hitachi PAS-48BUFASDQ1 good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 39,500 BTU/h at 5°F with a COP of 2.10, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
- How much does the Hitachi PAS-48BUFASDQ1 cost to run per year?
- At its rated efficiency it costs about $1,034-$2,752 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,273 in Phoenix and $2,298 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Hitachi PAS-48BUFASDQ1?
- ENERGY STAR lists 5 certified combinations for this outdoor unit. The highest-rated ones use HITACHI PCI-B48UFA1DQ, HITACHI PPIM-B48UFA1DQ, HITACHI PPFC-B48UFA1DQ.
- What refrigerant does the Hitachi PAS-48BUFASDQ1 use?
- It uses R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 42,000 BTU models
- GE Appliances 5G42ED2BE · cold climate20.5 SEER2 · 9.5 HSPF2
- York YPAS48BUFASDQ1 · cold climate20.0 SEER2 · 10.8 HSPF2
- Lennox MMPD048S6M-1P21.0 SEER2 · 9.0 HSPF2
- Friedrich FPHFR48A3D · cold climate20.0 SEER2 · 10.0 HSPF2
- TOSOT TM42H32MO · cold climate21.0 SEER2 · 10.0 HSPF2
- Daikin 5MXT40AVJU · cold climate20.0 SEER2 · 9.5 HSPF2
- TOSOT TM42D6MO · cold climate21.0 SEER2 · 10.0 HSPF2
- Guardian UPC48CN23STG1 · cold climate20.0 SEER2 · 9.5 HSPF2
See all 61 42,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of August 11, 2026. How we use the data.