18,000 BTU mini-split heat pump · A-KHP Series
KERR A-KHP18SA-1
Below average cooling efficiency and excellent heating efficiency for a 18,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #298 of 465 18,000 BTU mini-splits for cooling efficiency, and costs about $412 a year to run in a mixed climate like Atlanta.
- SEER2
- 21.4 Cooling efficiency over a seasonBelow average · beats 36%
- HSPF2
- 12.3 Heating efficiency over a seasonExcellent · beats 92%
- EER2
- 12.5 Cooling efficiency on a 95°F dayAverage · beats 44%
- Heat at 5°F
- 18,000 BTU/h100% of its 47°F outputVery good · beats 78%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 18,000 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 92% of mini-splits.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Cooling cost matters most - its SEER2 is below average for mini-splits.
Details
Specifications
| General | |
|---|---|
| Brand | KERR |
| Also sold as | Custom Comfort, Sea Breeze |
| Outdoor unit model | A-KHP18SA-1 |
| Series | A-KHP Series |
| Type | Mini-split heat pump |
| Nominal size | 18,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | November 11, 2024 |
| Last certified | May 28, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 21.4 (range 18.0-21.4) |
| EER2Efficiency at 95°F outdoors | 12.0-12.5 |
| Cooling capacity | 16,000-18,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 10.0-12.3 |
| Capacity at 47°F | 17,000-20,000 BTU/h |
| Capacity at 17°F | 14,000-18,000 BTU/h |
| Capacity at 5°F | 17,000-18,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.86-2.20 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with B-KHP18SA-1 at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| B-KHP18SA-1 Kerr · cold climate | 21.4 | 12.5 | 11.0 | 18,000 | 216097113 |
| B-KHP181A-1 Kerr · cold climate | 20.6 | 12.5 | 12.2 | 17,500 | 217482429 |
| B-KHP18UA-1 Kerr · cold climate | 20.4 | 12.5 | 10.3 | 17,000 | 217482432 |
| B-KHP18CA-1 Kerr · cold climate | 20.0 | 12.5 | 12.3 | 17,000 | 217482430 |
| B-KHP18WA-1 Kerr · cold climate | 20.0 | 12.5 | 10.3 | 17,500 | 217482431 |
| B-KHP18DA-1 Kerr · cold climate | 18.4 | 12.0 | 11.1 | 18,000 | 217482433 |
| B-KHP18AA-1 · cold climate | 18.0 | 12.0 | 10.0 | 18,000 | 216097089 |
Same unit, other model numbers
These model numbers have exactly the same certified ratings and matchups as the KERR A-KHP18SA-1: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.
- Custom Comfort CCOXHBSZ17HP
- Sea Breeze HSZ18H525ZMO
Yearly running cost in 10 large cities
- Phoenix, AZ$457/yr
- Miami, FL$373/yr
- Houston, TX$410/yr
- Atlanta, GA$412/yr
- Los Angeles, CA$400/yr
- New York, NY$980/yr
- Chicago, IL$795/yr
- Denver, CO$660/yr
- Seattle, WA$405/yr
- Minneapolis, MN$817/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the KERR A-KHP18SA-1?
- The KERR A-KHP18SA-1 is rated at up to 21.4 SEER2 and 12.5 EER2 for cooling and up to 12.3 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 7 certified matchups SEER2 ranges from 18.0-21.4.
- Is the KERR A-KHP18SA-1 good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 18,000 BTU/h at 5°F with a COP of 2.20, so it is still 2.2 times as efficient as electric resistance heat at that temperature.
- How much does the KERR A-KHP18SA-1 cost to run per year?
- At its rated efficiency it costs about $373-$980 a year in electricity in large U.S. cities, depending on climate and local rates - for example $457 in Phoenix and $817 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Is the KERR A-KHP18SA-1 the same as the Custom Comfort CCOXHBSZ17HP?
- Yes, as far as the certified ratings go. ENERGY STAR lists 3 model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
- Which indoor units work with the KERR A-KHP18SA-1?
- ENERGY STAR lists 7 certified combinations for this outdoor unit. The highest-rated ones use Kerr B-KHP18SA-1, Kerr B-KHP181A-1, Kerr B-KHP18UA-1.
- What refrigerant does the KERR A-KHP18SA-1 use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 18,000 BTU models
- ECO-AIR EDSO-18H · cold climate21.4 SEER2 · 12.3 HSPF2
- Midea MO1HS-H18B-2A · cold climate21.4 SEER2 · 12.3 HSPF2
- DIRECT AIR DIRM4-18HXPRO28-1Z · cold climate21.4 SEER2 · 12.3 HSPF2
- MOOVAIR MSHMA18C2AN1 · cold climate21.4 SEER2 · 12.3 HSPF2
- Comfort-Aire A-VHP18SA-1 · cold climate21.4 SEER2 · 12.3 HSPF2
- MRCOOL O-HH-18-HP-C-230C-O · cold climate21.4 SEER2 · 12.3 HSPF2
- Capella CPPB-H18A-O · cold climate21.4 SEER2 · 12.3 HSPF2
- Napoleon NDHAS26BA-18-O · cold climate21.4 SEER2 · 12.3 HSPF2
See all 465 18,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 28, 2026. How we use the data.