24,000 BTU mini-split heat pump · A series
KERR A-KMH24SU-1A
Below average cooling efficiency and very good heating efficiency for a 24,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #307 of 430 24,000 BTU mini-splits for cooling efficiency, and costs about $606 a year to run in a mixed climate like Atlanta.
- SEER2
- 20.5 Cooling efficiency over a seasonBelow average · beats 24%
- HSPF2
- 11.0 Heating efficiency over a seasonVery good · beats 75%
- EER2
- 11.7 Cooling efficiency on a 95°F dayBelow average · beats 16%
- Heat at 5°F
- 27,000 BTU/h100% of its 47°F outputAverage · beats 67%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 27,000 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 75% of mini-splits.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Cooling cost matters most - its SEER2 is below average for mini-splits.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | KERR |
| Outdoor unit model | A-KMH24SU-1A |
| Series | A series |
| Type | Mini-split heat pump |
| Nominal size | 24,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | December 18, 2019 |
| Last certified | June 13, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 20.5 (range 18.9-20.5) |
| EER2Efficiency at 95°F outdoors | 11.7-12.0 |
| Cooling capacity | 21,600-24,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 10.4-11.0 |
| Capacity at 47°F | 23,400-25,000 BTU/h |
| Capacity at 17°F | 19,000-21,000 BTU/h |
| Capacity at 5°F | 23,400-27,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.89-2.10 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with B-KMH24UU-1 at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| B-KMH24UU-1 · cold climate | 20.5 | 11.7 | 11.0 | 25,000 | 206347323 |
| B-KMH24DU-1 · cold climate | 19.2 | 12.0 | 10.5 | 27,000 | 206347321 |
| B-KMH24SU-1 · cold climate | 18.9 | 11.7 | 10.4 | 23,400 | 206913038 |
| B-KMH24SU-1A · cold climate | 18.9 | 11.7 | 10.4 | 23,400 | 206221393 |
Yearly running cost in 10 large cities
- Phoenix, AZ$674/yr
- Miami, FL$550/yr
- Houston, TX$604/yr
- Atlanta, GA$606/yr
- Los Angeles, CA$589/yr
- New York, NY$1,442/yr
- Chicago, IL$1,170/yr
- Denver, CO$972/yr
- Seattle, WA$596/yr
- Minneapolis, MN$1,202/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the KERR A-KMH24SU-1A?
- The KERR A-KMH24SU-1A is rated at up to 20.5 SEER2 and 11.7 EER2 for cooling and up to 11.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 4 certified matchups SEER2 ranges from 18.9-20.5.
- Is the KERR A-KMH24SU-1A good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 27,000 BTU/h at 5°F with a COP of 2.10, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
- How much does the KERR A-KMH24SU-1A cost to run per year?
- At its rated efficiency it costs about $550-$1,442 a year in electricity in large U.S. cities, depending on climate and local rates - for example $674 in Phoenix and $1,202 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the KERR A-KMH24SU-1A?
- ENERGY STAR lists 4 certified combinations for this outdoor unit. The highest-rated ones use B-KMH24UU-1, B-KMH24DU-1, B-KMH24SU-1.
- What refrigerant does the KERR A-KMH24SU-1A use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 24,000 BTU models
- Elios DEA24HOS28230E8 · cold climate20.5 SEER2 · 11.5 HSPF2
- Panasonic CS-Z24AKUAW/CU-XZ24AKUAC · cold climate20.5 SEER2 · 11.0 HSPF2
- Fujitsu AOU24RGLX20.8 SEER2 · 10.1 HSPF2
- Panasonic CU-XZ24AKUAC · cold climate20.5 SEER2 · 11.0 HSPF2
- TOSOT TAY18-24H1B21.0 SEER2 · 8.0 HSPF2
- Goodman MST273G22MHAA · cold climate20.5 SEER2 · 10.0 HSPF2
- GREE GWH24AYEXF-D6DNA1K/O21.0 SEER2 · 8.0 HSPF2
- Hitachi RAS-3.0PNNBDH1 · cold climate20.5 SEER2 · 10.0 HSPF2
See all 430 24,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 13, 2026. How we use the data.