24,000 BTU mini-split heat pump · M3O Series

Koolking M3OF-27HFN1-M

Average cooling efficiency and below average heating efficiency for a 24,000 BTU mini-split heat pump, and certified for cold climates.

Ranks #201 of 430 24,000 BTU mini-splits for cooling efficiency, and costs about $707 a year to run in a mixed climate like Atlanta.

SEER2
22.0 Cooling efficiency over a season
Average · beats 48%
HSPF2
9.6 Heating efficiency over a season
Below average · beats 30%
EER2
11.5 Cooling efficiency on a 95°F day
Below average · beats 13%
Heat at 5°F
22,600 BTU/h84% of its 47°F output
Average · beats 61%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 22,600 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • You mainly need heat - its HSPF2 is below average for mini-splits.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications24,000 BTU, R-410A
General
BrandKoolking
Outdoor unit modelM3OF-27HFN1-M
SeriesM3O Series
TypeMini-split heat pump
Nominal size24,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceMarch 16, 2018
Last certifiedJuly 17, 2025
Cooling
SEER2Seasonal efficiency, higher is better22.0 (range 22.0)
EER2Efficiency at 95°F outdoors11.5
Cooling capacity27,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better9.6
Capacity at 47°F27,000 BTU/h
Capacity at 17°F17,800 BTU/h
Capacity at 5°F22,600 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.06
ENERGY STAR cold climateYes
Heating output as it gets colder84% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:

Certified matchups1 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
- KOOLKING · cold climate22.011.59.622,600201863418
Yearly running cost in 10 large cities$580-$1,732

At each state's average electricity price and the city's typical heating and cooling hours.

Questions4
What is the SEER2 rating of the Koolking M3OF-27HFN1-M?
The Koolking M3OF-27HFN1-M is rated at up to 22.0 SEER2 and 11.5 EER2 for cooling and up to 9.6 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
Is the Koolking M3OF-27HFN1-M good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 22,600 BTU/h at 5°F with a COP of 2.06, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
How much does the Koolking M3OF-27HFN1-M cost to run per year?
At its rated efficiency it costs about $580-$1,732 a year in electricity in large U.S. cities, depending on climate and local rates - for example $740 in Phoenix and $1,466 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
What refrigerant does the Koolking M3OF-27HFN1-M use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $747/yrYou save $645/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Koolking M3OF-27HFN1-M
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$747
Current system, per year
$1,392
You save per year
$645
Payback
15.5 years
Net after 10 years
-$3,548

Cooling $432Heating $315Electricity used: 4,669 kWhSaved vs. a minimum-efficiency heat pump: $321

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 24,000 BTU models

See all 430 24,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 17, 2025. How we use the data.